10 More Discussions You Might Find Interesting
1. AIX
Hello,
I would like to check how many SAS disks and its size per disk for the whole power system. As per my understanding, if we assign the SAS controller to LPAR, then we can see the disk in lpar smitty command.
How can we check from the Power machine(physical ones) as well? I think the... (5 Replies)
Discussion started by: Phat
5 Replies
2. Filesystems, Disks and Memory
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Discussion started by: terrya
1 Replies
3. Red Hat
I need to add a VMware virtual disk to the 99-oracle-asmdevices.rules file but the OS is not assigning a WWID to the disk. It has been fdisk'd and a single partition created.
What TAG inside the file needs to be added? the Program scsi-id does not work for some reason. latest patches... (0 Replies)
Discussion started by: mrmurdock
0 Replies
4. Linux
Hi,
a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced.
here is how I did that.
1) created identical partition table on the new disk.
2) attached the mirrors using md commands.
The whole procedure is given below:... (2 Replies)
Discussion started by: busyboy
2 Replies
5. Ubuntu
Hi,
a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced.
here is how I did that.
1) created identical partition table on the new disk.
2) attached the mirrors using md commands.
The whole procedure is given... (5 Replies)
Discussion started by: busyboy
5 Replies
6. UNIX for Dummies Questions & Answers
Hi,
Is there an easy way to find the disk-type from the command line or with another api ? sdparm works for SAS but not for SATA, hdparm works for SATA but not SAS.
Thanks (1 Reply)
Discussion started by: coderd
1 Replies
7. Solaris
Hi,
I`m on SunFire480R with Solaris 10. Disk in rootdg group failed, so it was replaced. However, I cannot make Veritas initalise the replaced disk:
# vxdctl enable
# vxdisk list c1t0d0s2
Device: c1t0d0s2
devicetag: c1t0d0
type: auto
flags: online error private autoconfig... (1 Reply)
Discussion started by: masloff
1 Replies
8. AIX
May I know how can I add a new SSA pdisk into array and become usable hdisk? I have inserted a 36GB SSA disk into enclosure and done the "cfgmgr" and I can see it already been regconized as pdisk47.
I would like to make it a system disk in order for me to add to my volume group. Please let me... (3 Replies)
Discussion started by: kwliew999
3 Replies
9. Solaris
We have a dual-controller StorEdge 3320 disk array with 5 disks (each 320 MB). Four disks have been set up in a RAID-5 configuration with the remaining disk acting as a hot spare. There is a single logical drive which has been partitioned into 3 slices.
The disk array is to be simultaneously... (14 Replies)
Discussion started by: StarSol
14 Replies
10. Solaris
Dear Friends,
I need to configure T5240 with Internal SAS RAID HBA(SG-XPCIESAS-R-INT-Z).. T5240 uses 8 hard disks... From the documents of RAID card I have found that I need to create a jump start server to include three packages SUNWaac, StorMan, SUNWgccruntime if Im using solaris10 5/08...
... (5 Replies)
Discussion started by: nicktrix
5 Replies