Replaced pdisk not showing up in SAS Disk Array Configuration

Code:
OSLevel: 5300-10-02-0943
System Model: IBM,8203-E4A
Power 6
==

Hi!
I replaced a failed pdisk in the raid enclosure as follows,
Code:
- rmdev -l 'pdisk18' '-d'
- Replaced it.
- cfgmgr  (detected)

- I can see the new drive, with the correct serial #
Code:
lscfg -v -l pdisk18
pdisk18 U5886.001.P15R082-P1-D3 Physical SAS Disk Drive

Manufacturer................IBM 
Machine Type and Model......ST3300656SS 
FRU Number..................10N7208 
ROS Level and ID............45363043
Serial Number...............3QP2CYYW

However, when trying to Create an Array Candidate pdisk and Format to 528 Byte Sectors it doesn't show up.
==
 Create an Array Candidate pdisk and Format to 528 Byte Sectors     
                                                                              
                       │   pdisk22   00000600  Active      Array Candidate        283.8GB         │
                       │   pdisk23   00000700  Active      Array Candidate        283.8GB         │
                       │   pdisk24   00000800  Active      Array Candidate        283.8GB         │
                       │   pdisk25   00000900  Active      Array Candidate        283.8GB   

===
Neither in the array conf:

sissas3   FFFFFFFF  Primary     PCI-X266 Ext Tri-x4 3Gb SAS RAID Adapter
 sissas2  00000000  AWC linked  Redundant cache protection for sissas3

hdisk9    00FF0000  Degraded    RAID 10 Array          851.4GB
 pdisk21  00000500  Active      Array Member           283.8GB
 pdisk27  00000B00  Active      Array Member           283.8GB
 pdisk17  00000100  Active      Array Member           283.8GB
 pdisk20  00000400  Active      Array Member           283.8GB
 pdisk16  00000000  Active      Array Member           283.8GB
 pdisk19  00000300  Active      Array Member           283.8GB

pdisk24   00000800  Active      Array Candidate        283.8GB
pdisk22   00000600  Active      Array Candidate        283.8GB
pdisk23   00000700  Active      Array Candidate        283.8GB
pdisk25   00000900  Active      Array Candidate        283.8GB
pdisk26   00000A00  Active      Hot Spare              283.8GB
pdisk18   00000200  Missing     Disk                   283.8GB

I will appreciate your help,

Thank you,
# 2  
Old 06-21-2019
I'll start by stating that I'm not an AIX person and I'm not familiar with the RAID controller you have there. I am a storage person.

However, with a part number of ST3300656SS that is not a disk manufactured by IBM; it is OEM'd from Seagate.

I'm well aware that Seagate disks of the exact same part number can have a slightly different LBA count and when the LBA count is less than the existing RAID members, the RAID controller refuses to configure it. So just be aware and don't fall for that one.

Check that the LBA's on the disk you replaced is at least equal, or more than, the existing RAID members.

EDIT: The total LBA's (Logical blocks) are usually written on the disk label.

Last edited by hicksd8; 06-21-2019 at 02:38 PM..
These 2 Users Gave Thanks to hicksd8 For This Post:
# 3  
Old 06-24-2019
I used a different model (HUS153030VLS300) and it worked,

Thank you for the suggestion,

Regards
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. AIX

Power machine 720 SAS disk

Hello, I would like to check how many SAS disks and its size per disk for the whole power system. As per my understanding, if we assign the SAS controller to LPAR, then we can see the disk in lpar smitty command. How can we check from the Power machine(physical ones) as well? I think the... (5 Replies)
Discussion started by: Phat
5 Replies

2. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

3. Red Hat

Udev Rule TAG for identifying a local sas disk, non-scsi, non-fiber, non-iscsi

I need to add a VMware virtual disk to the 99-oracle-asmdevices.rules file but the OS is not assigning a WWID to the disk. It has been fdisk'd and a single partition created. What TAG inside the file needs to be added? the Program scsi-id does not work for some reason. latest patches... (0 Replies)
Discussion started by: mrmurdock
0 Replies

4. Linux

Grub not loading from replaced disk

Hi, a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced. here is how I did that. 1) created identical partition table on the new disk. 2) attached the mirrors using md commands. The whole procedure is given below:... (2 Replies)
Discussion started by: busyboy
2 Replies

5. Ubuntu

Linux LVM.. Grub not loading from replaced disk

Hi, a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced. here is how I did that. 1) created identical partition table on the new disk. 2) attached the mirrors using md commands. The whole procedure is given... (5 Replies)
Discussion started by: busyboy
5 Replies

6. UNIX for Dummies Questions & Answers

find physical disk type : SAS / SATA

Hi, Is there an easy way to find the disk-type from the command line or with another api ? sdparm works for SAS but not for SATA, hdparm works for SATA but not SAS. Thanks (1 Reply)
Discussion started by: coderd
1 Replies

7. Solaris

Veritas not attaching replaced disk

Hi, I`m on SunFire480R with Solaris 10. Disk in rootdg group failed, so it was replaced. However, I cannot make Veritas initalise the replaced disk: # vxdctl enable # vxdisk list c1t0d0s2 Device: c1t0d0s2 devicetag: c1t0d0 type: auto flags: online error private autoconfig... (1 Reply)
Discussion started by: masloff
1 Replies

8. AIX

add SSA pdisk to array to become hdisk

May I know how can I add a new SSA pdisk into array and become usable hdisk? I have inserted a 36GB SSA disk into enclosure and done the "cfgmgr" and I can see it already been regconized as pdisk47. I would like to make it a system disk in order for me to add to my volume group. Please let me... (3 Replies)
Discussion started by: kwliew999
3 Replies

9. Solaris

3320 Disk Array Configuration for Oracle 10

We have a dual-controller StorEdge 3320 disk array with 5 disks (each 320 MB). Four disks have been set up in a RAID-5 configuration with the remaining disk acting as a hot spare. There is a single logical drive which has been partitioned into 3 slices. The disk array is to be simultaneously... (14 Replies)
Discussion started by: StarSol
14 Replies

10. Solaris

T5240 and Internal SAS RAID Configuration help

Dear Friends, I need to configure T5240 with Internal SAS RAID HBA(SG-XPCIESAS-R-INT-Z).. T5240 uses 8 hard disks... From the documents of RAID card I have found that I need to create a jump start server to include three packages SUNWaac, StorMan, SUNWgccruntime if Im using solaris10 5/08... ... (5 Replies)
Discussion started by: nicktrix
5 Replies
Login or Register to Ask a Question