PROFILE FOR STORAGE SUBSYSTEM: Unnamed (8/30/13 11:36:31 PM) SUMMARY------------------------------ Number of controllers: 2 Number of arrays: 1 Total number of logical drives (includes an access logical drive): 2 of 1024 used Number of standard logical drives: 1 Number of access logical drives: 1 Number of drives: 8 Supported drive types: Fibre (8) Total hot spare drives: 0 Standby: 0 In use: 0 Access logical drive: LUN 31 (see Mappings section for details) Default host OS: AIX (Host OS index 6) Current configuration Firmware version: 06.60.34.00 NVSRAM version: N1722F600R912V13 Pending configuration Staged firmware download supported: Yes Firmware version: None NVSRAM version: None Transferred on: None Controller enclosure audible alarm: Disabled NVSRAM configured for batteries: Yes Start cache flushing at (in percentage): 80 Stop cache flushing at (in percentage): 80 Cache block size (in KB): 4 Media scan frequency (in days): 30 Failover alert delay (in minutes): 5 Feature enable identifier: 39353036340000000000000044589E11 Storage Subsystem worldwide name (ID): 600A0B800016A137000000005127AFF6 Management software version: 09.60.G5.56 CONTROLLERS------------------------------ Number of controllers: 2 Controller in Enclosure 0, Slot A Status: Online Current configuration Firmware version: 06.60.34.00 Appware version: 06.60.34.00 Bootware version: 06.60.34.00 NVSRAM version: N1722F600R912V13 Pending configuration Firmware version: None Appware version: None Bootware version: None NVSRAM version: None Transferred on: None Current ID (ALPA) On drive channel 1: 125/0x1 On drive channel 2: 125/0x1 Replacement part number: Not Available Board ID: 2882 Product ID: 1742-900 Product revision: 0914 Serial number: 1T54956439 Date of manufacture: December 20, 2005 Vendor: IBM Cache Total data cache: 864 MB Processor cache: 160 MB Associated Logical Drives (* = Preferred Owner): None Controller host name: target Remote login: Disabled Ethernet port: 1 MAC address: 00:a0:b8:19:91:a9 Network configuration: Static IP address: 10.1.1.20 Subnet mask: 255.255.0.0 Gateway: 0.0.0.0 Drive interface: Fibre Channel: 1 Current ID: 125/0x1 Maximum data rate: 2 Gbps Current data rate: 2 Gbps Data rate control: Fixed Link status: Up Drive interface: Fibre Channel: 2 Current ID: 125/0x1 Maximum data rate: 2 Gbps Current data rate: 2 Gbps Data rate control: Fixed Link status: Up Host interface: Fibre Channel: 1 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 0/0xEF NL-Port ID: 0x670800 Maximum data rate: 2 Gbps Current data rate: 2 Gbps Data rate control: Auto Link status: Up Topology: Fabric Attach World-wide port name: 20:0a:00:a0:b8:12:3b:3e World-wide node name: 20:0a:00:a0:b8:12:3b:3d Part type: HPFC-5400 revision 6 Host interface: Fibre Channel: 2 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 1/0xE8 NL-Port ID: 0xFFFFFF Maximum data rate: 2 Gbps Current data rate: 2 Gbps Data rate control: Auto Link status: Down Topology: Not Available World-wide port name: 20:0a:00:a0:b8:12:3b:3f World-wide node name: 20:0a:00:a0:b8:12:3b:3d Part type: HPFC-5400 revision 6 Controller in Enclosure 0, Slot B Status: Online Current configuration Firmware version: 06.60.34.00 Appware version: 06.60.34.00 Bootware version: 06.60.34.00 NVSRAM version: N1722F600R912V13 Pending configuration Firmware version: None Appware version: None Bootware version: None NVSRAM version: None Transferred on: None Current ID (ALPA) On drive channel 1: 124/0x2 On drive channel 2: 124/0x2 Replacement part number: Not Available Board ID: 2882 Product ID: 1722-600 Product revision: 0914 Serial number: 1T53886644 Date of manufacture: September 20, 2005 Vendor: IBM Cache Total data cache: 864 MB Processor cache: 160 MB Associated Logical Drives (* = Preferred Owner): test* Controller host name: ds4300 Remote login: Disabled Ethernet port: 1 MAC address: 00:a0:b8:19:b0:57 Network configuration: Static IP address: 10.1.1.21 Subnet mask: 255.255.0.0 Gateway: 0.0.0.0 Drive interface: Fibre Channel: 1 Current ID: 124/0x2 Maximum data rate: 2 Gbps Current data rate: 2 Gbps Data rate control: Fixed Link status: Up Drive interface: Fibre Channel: 2 Current ID: 124/0x2 Maximum data rate: 2 Gbps Current data rate: 2 Gbps Data rate control: Fixed Link status: Up Host interface: Fibre Channel: 1 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 2/0xE4 NL-Port ID: 0x670900 Maximum data rate: 2 Gbps Current data rate: 2 Gbps Data rate control: Auto Link status: Up Topology: Fabric Attach World-wide port name: 20:0b:00:a0:b8:12:3b:3e World-wide node name: 20:0a:00:a0:b8:12:3b:3d Part type: HPFC-5400 revision 6 Host interface: Fibre Channel: 2 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 3/0xE2 NL-Port ID: 0xFFFFFF Maximum data rate: 2 Gbps Current data rate: 2 Gbps Data rate control: Auto Link status: Down Topology: Not Available World-wide port name: 20:0b:00:a0:b8:12:3b:3f World-wide node name: 20:0a:00:a0:b8:12:3b:3d Part type: HPFC-5400 revision 6 ARRAYS------------------------------ Number of arrays: 1 ARRAY 1 (RAID 0) Array status: Online Drive type: Fibre Channel Enclosure loss protection: No Current owner: Controller in slot B Associated logical drives and free capacities: LOGICAL DRIVE NAME CAPACITY test 278.896 GB Associated drives (in piece order): ENCLOSURE SLOT 0 1 STANDARD LOGICAL DRIVES------------------------------ SUMMARY Number of standard logical drives: 1 See other Logical Drives sub-tabs for premium feature information. NAME STATUS CAPACITY RAID LEVEL ARRAY test Optimal 278.896 GB 0 1 DETAILS LOGICAL DRIVE NAME: test Logical Drive status: Optimal Capacity: 278.896 GB (299,462,819,840 Bytes) Logical Drive ID: 60:0a:0b:80:00:19:b0:57:00:00:0c:76:52:20:8f:15 Subsystem ID (SSID): 0 Associated array: 1 RAID level: 0 Drive type: Fibre Channel Enclosure loss protection: No Preferred owner: Controller in slot B Current owner: Controller in slot B Segment size: 128 KB Modification priority: High Read cache: Enabled Write cache: Enabled Write cache without batteries: Disabled Write cache with mirroring: Enabled Flush write cache after (in seconds): 10.00 Dynamic cache read prefetch: Enabled Enable background media scan: Enabled Media scan with redundancy check: Disabled MISSING LOGICAL DRIVES------------------------------ Number of missing logical drives: 0 DRIVES------------------------------ SUMMARY Number of drives: 8 Current drive types: Fibre (8) BASIC: TRAY, SLOT STATUS CAPACITY CURRENT DATA RATE PRODUCT ID FIRMWARE VERSION 0, 1 Optimal 279.397 GB 2 Gbps HUS103030FLF21 JFQ8 0, 2 Optimal 279.397 GB 2 Gbps HUS103030FLF21 JFQ8 0, 3 Optimal 279.397 GB 2 Gbps HUS103030FLF21 JFQ8 0, 4 Optimal 279.397 GB 2 Gbps HUS103030FLF21 JFQ8 0, 5 Optimal 279.397 GB 2 Gbps HUS103030FLF21 JFQ8 0, 6 Optimal 279.397 GB 2 Gbps HUS103030FLF21 JFQ8 0, 7 Optimal 279.397 GB 2 Gbps HUS103030FLF21 JFQ8 0, 8 Optimal 279.397 GB 2 Gbps HUS103030FLF21 JFQ8 DRIVE CHANNELS: TRAY, SLOT PREFERRED CHANNEL REDUNDANT CHANNEL 0, 1 1 2 0, 2 2 1 0, 3 1 2 0, 4 2 1 0, 5 1 2 0, 6 2 1 0, 7 1 2 0, 8 2 1 HOT SPARE COVERAGE: The following arrays are not protected: 1 Total hot spare drives: 0 Standby: 0 In use: 0 DETAILS Drive at Enclosure 0, Slot 1 Status: Optimal Mode: Assigned Raw capacity: 279.397 GB Usable capacity: 278.897 GB World-wide name: 20:00:00:00:87:90:cd:a6 Associated array: 1 PORT CHANNEL ID 0 1 0/0xEF 1 2 0/0xEF Drive path redundancy: OK Drive type: Fibre Channel Speed: 10000 RPM Current data rate: 2 Gbps Product ID: HUS103030FLF21 Firmware version: JFQ8 Serial number: VAVVP93A Vendor: IBM-SSG Date of manufacture: April 14, 2006 Drive at Enclosure 0, Slot 2 Status: Optimal Mode: Unassigned Raw capacity: 279.397 GB Usable capacity: 278.897 GB World-wide name: 20:00:00:00:87:45:d1:1e Associated array: None PORT CHANNEL ID 0 2 1/0xE8 1 1 1/0xE8 Drive path redundancy: OK Drive type: Fibre Channel Speed: 10000 RPM Current data rate: 2 Gbps Product ID: HUS103030FLF21 Firmware version: JFQ8 Serial number: VAVUV1DA Vendor: IBM-SSG Date of manufacture: March 20, 2006 Drive at Enclosure 0, Slot 3 Status: Optimal Mode: Unassigned Raw capacity: 279.397 GB Usable capacity: 278.897 GB World-wide name: 20:00:00:00:87:45:56:1c Associated array: None PORT CHANNEL ID 0 1 2/0xE4 1 2 2/0xE4 Drive path redundancy: OK Drive type: Fibre Channel Speed: 10000 RPM Current data rate: 2 Gbps Product ID: HUS103030FLF21 Firmware version: JFQ8 Serial number: VAVUAZDA Vendor: IBM-SSG Date of manufacture: March 20, 2006 Drive at Enclosure 0, Slot 4 Status: Optimal Mode: Unassigned Raw capacity: 279.397 GB Usable capacity: 278.897 GB World-wide name: 20:00:00:00:87:a8:fd:1f Associated array: None PORT CHANNEL ID 0 2 3/0xE2 1 1 3/0xE2 Drive path redundancy: OK Drive type: Fibre Channel Speed: 10000 RPM Current data rate: 2 Gbps Product ID: HUS103030FLF21 Firmware version: JFQ8 Serial number: VAWTVX2A Vendor: IBM-SSG Date of manufacture: May 2, 2007 Drive at Enclosure 0, Slot 5 Status: Optimal Mode: Unassigned Raw capacity: 279.397 GB Usable capacity: 278.897 GB World-wide name: 20:00:00:00:87:ab:0f:a8 Associated array: None PORT CHANNEL ID 0 1 4/0xE1 1 2 4/0xE1 Drive path redundancy: OK Drive type: Fibre Channel Speed: 10000 RPM Current data rate: 2 Gbps Product ID: HUS103030FLF21 Firmware version: JFQ8 Serial number: VAWWDVGA Vendor: IBM-SSG Date of manufacture: June 6, 2007 Drive at Enclosure 0, Slot 6 Status: Optimal Mode: Unassigned Raw capacity: 279.397 GB Usable capacity: 278.897 GB World-wide name: 20:00:00:00:87:8f:49:ef Associated array: None PORT CHANNEL ID 0 2 5/0xE0 1 1 5/0xE0 Drive path redundancy: OK Drive type: Fibre Channel Speed: 10000 RPM Current data rate: 2 Gbps Product ID: HUS103030FLF21 Firmware version: JFQ8 Serial number: VAVT6UXA Vendor: IBM-SSG Date of manufacture: February 27, 2006 Drive at Enclosure 0, Slot 7 Status: Optimal Mode: Unassigned Raw capacity: 279.397 GB Usable capacity: 278.897 GB World-wide name: 20:00:00:00:87:47:c5:b9 Associated array: None PORT CHANNEL ID 0 1 6/0xDC 1 2 6/0xDC Drive path redundancy: OK Drive type: Fibre Channel Speed: 10000 RPM Current data rate: 2 Gbps Product ID: HUS103030FLF21 Firmware version: JFQ8 Serial number: VAVV9SKA Vendor: IBM-SSG Date of manufacture: April 14, 2006 Drive at Enclosure 0, Slot 8 Status: Optimal Mode: Unassigned Raw capacity: 279.397 GB Usable capacity: 278.897 GB World-wide name: 20:00:00:00:87:91:41:9f Associated array: None PORT CHANNEL ID 0 2 7/0xDA 1 1 7/0xDA Drive path redundancy: OK Drive type: Fibre Channel Speed: 10000 RPM Current data rate: 2 Gbps Product ID: HUS103030FLF21 Firmware version: JFQ8 Serial number: VAVV3JDA Vendor: IBM-SSG Date of manufacture: April 14, 2006 DRIVE CHANNELS---------------------------- SUMMARY CHANNEL STATUS CTRL A LINK CTRL B LINK 1 Optimal Up Up 2 Optimal Up Up DETAILS DRIVE CHANNEL 1 Status: Optimal Max. Rate: 2 Gbps Current Rate: 2 Gbps Rate Control: Fixed Controller A link status: Up Controller B link status: Up DRIVE COUNTS Total # of attached drives: 8 Connected to: Controller A Attached drives: 8 Drive enclosure: 0 (8 drives) CUMULATIVE ERROR COUNTS Controller A Baseline time set: 8/30/13 11:02:09 PM Sample period (hh:mm:ss): 00:33:31 Controller detected errors: 0 Drive detected errors: 0 Timeout errors: 0 Link down errors: 1 Total I/O count: 9770 Controller B Baseline time set: 8/30/13 11:02:11 PM Sample period (hh:mm:ss): 00:33:29 Controller detected errors: 0 Drive detected errors: 0 Timeout errors: 0 Link down errors: 0 Total I/O count: 6117 DRIVE CHANNEL 2 Status: Optimal Max. Rate: 2 Gbps Current Rate: 2 Gbps Rate Control: Fixed Controller A link status: Up Controller B link status: Up DRIVE COUNTS Total # of attached drives: 8 Connected to: Controller B Attached drives: 8 Drive enclosure: 0 (8 drives) CUMULATIVE ERROR COUNTS Controller A Baseline time set: 8/30/13 11:02:10 PM Sample period (hh:mm:ss): 00:33:30 Controller detected errors: 0 Drive detected errors: 0 Timeout errors: 0 Link down errors: 0 Total I/O count: 9963 Controller B Baseline time set: 8/30/13 11:02:11 PM Sample period (hh:mm:ss): 00:33:29 Controller detected errors: 0 Drive detected errors: 0 Timeout errors: 0 Link down errors: 0 Total I/O count: 6058 ENCLOSURES------------------------------ Controller/Drive Enclosure Overall Component Information Enclosure audible alarm: Disabled Enclosure path redundancy: OK Current drive types: Fibre channel Part number: PN 24P8129 Serial number: SN 13G4588 Vendor: VN IBM Date of manufacture: March 1, 2004 2 Batteries Detected Battery status: Optimal Location: Controller A Age: 115 days Days until replacement: 3,574 days Part number: Not Available Serial number: Not Available Vendor: Not Available Date of manufacture: Not Available Battery status: Optimal Location: Controller B Age: 115 days Days until replacement: 3,574 days Part number: Not Available Serial number: Not Available Vendor: Not Available Date of manufacture: Not Available 2 Fan Canisters Detected Fan Status: Optimal Location: Fan canister (left) Fan Status: Optimal Location: Fan canister (right) 2 Power Supply Canisters Detected Power supply status: Optimal Location: Power supply canister (left) Part number: PN 19K1289 Serial number: SN A6846A00860F Vendor: VN IBM Date of manufacture: January 1, 2004 Power supply status: Optimal Location: Power supply canister (right) Part number: PN 19K1289 Serial number: SN A6846A00870F Vendor: VN IBM Date of manufacture: January 1, 2004 6 SFPs Detected SFP status: Optimal Attached to: Host-side of controller A Location: Channel 1 Supported data rate(s): 1 Gbps, 2 Gbps Link length: Intermediate Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6) IEEE company ID: 00 01 9c Revision: Part number: JSP-21S0AA1 Serial number: F55043504503 Vendor: JDS UNIPHASE Date of manufacture: December 14, 2005 SFP status: Optimal Attached to: Host-side of controller A Location: Channel 2 Supported data rate(s): 1 Gbps, 2 Gbps Link length: Intermediate Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6) IEEE company ID: 00 01 9c Revision: Part number: JSP-21S0AA1 Serial number: F55043503466 Vendor: JDS UNIPHASE Date of manufacture: December 11, 2005 SFP status: Optimal Attached to: Drive-side of controller A Location: Expansion Supported data rate(s): 1 Gbps, 2 Gbps Link length: Intermediate Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6) IEEE company ID: 00 01 9c Revision: Part number: JSP-21S0AA1 Serial number: F550435048C3 Vendor: JDS UNIPHASE Date of manufacture: December 14, 2005 SFP status: Optimal Attached to: Host-side of controller B Location: Channel 1 Supported data rate(s): 1 Gbps, 2 Gbps Link length: Intermediate Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6) IEEE company ID: 00 01 9c Revision: Part number: JSP-21S0AA1 Serial number: F418435039FC Vendor: JDS UNIPHASE Date of manufacture: April 30, 2004 SFP status: Optimal Attached to: Host-side of controller B Location: Channel 2 Supported data rate(s): 1 Gbps, 2 Gbps Link length: Intermediate Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6) IEEE company ID: 00 01 9c Revision: Part number: JSP-21S0AA1 Serial number: F51043502B93 Vendor: JDS UNIPHASE Date of manufacture: March 3, 2005 SFP status: Optimal Attached to: Drive-side of controller B Location: Expansion Supported data rate(s): 1 Gbps, 2 Gbps Link length: Intermediate Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6) IEEE company ID: 00 01 9c Revision: Part number: JSP-21S0AA1 Serial number: F55043505381 Vendor: JDS UNIPHASE Date of manufacture: December 15, 2005 2 Temperature Sensors Detected Temperature sensor status: Optimal Location: Controller A Temperature sensor status: Optimal Location: Controller B MAPPINGS (Storage Partitioning - Disabled)------------------- VOLUME NAME LUN CONTROLLER ACCESSIBLE BY VOLUME STATUS Access Logical Drive 31 A,B Default Group Optimal test 9 B Default Group Optimal TOPOLOGY DEFINITIONS DEFAULT GROUP Default type: AIX NVSRAM HOST TYPE DEFINITIONS HOST TYPE ADT STATUS ASSOCIATED INDEX AIX Disabled 6 (Default) AIX0-ADT/AVT Enabled 4 DEFAULT Disabled 0 HP-UX Enabled 7 IBM TS SAN VCE Enabled 12 Irix Disabled 10 LNXCLVMWARE Disabled 13 Linux Enabled 5 Netware Failover Enabled 11 Solaris Disabled 8 Solaris (with Veritas DMP) Enabled 14 Unused1 Disabled 1 Windows 2000/Server 2003/Server 2008 Clustered Disabled 3 Windows 2000/Server 2003/Server 2008 Clustered (supports DMP) Enabled 15 Windows 2000/Server 2003/Server 2008 Non-Clustered Disabled 2 Windows 2000/Server 2003/Server 2008 Non-Clustered (supports DMP) Enabled 9
rmdev -Rdl fcs0 rmdev -Rdl fcs1 cfgmgr -v
# cfgmgr Method error (/usr/lib/methods/cfgefscsi -l fscsi1 ): 0514-061 Cannot find a child device.
|