i want configure a SEA over my vios ,
i have a message error :
Since it is an IVE logical port, it is likely that this VIOS needs to be configured as the IVE physical port's promiscuous logical partition
Command did not complete.
"Run mkdev" was last subcommand run.
please help me
Moderator's Comments:
edit by bakunin: even if you didn't say it this is clearly AIX. I am going to transfer this thread over to the AIX board. Please note too, that we really meant it when we asked you to use CODE-tags. Thanks
Just a moment, while i look at your screen to see which command you entered and what else you did.....
hmm, somehow my far-sight is distorted today and my crystal ball is being repaired.
Seriously: it would help to show what you did, not only the error code that resulted in. Could you please give us a complete description of your problem, then we could better help you.
Location: on the road for work; home is private time
Posts: 456
Thanks Given: 10
Thanked 108 Times in 100 Posts
As this is IVE (Integrated Virtual Ethernet) you need to be sure that the HEA (Hardware Ethernet Adapter) is configured in promiscuous mode, and the VIOS is the only system using the port.
Location: on the road for work; home is private time
Posts: 456
Thanks Given: 10
Thanked 108 Times in 100 Posts
I was waiting for other comments - it has been a while since I have been taught a class using HEA - the HMC code might be improved - but a few years back one of the common things that went wrong was that after a HEA port was configured into promiscuous mode people still tried to use it in multiple partitions and got mixed results.
So, in the HMC you need to open the HEA tab and verify the port is only assigned to a single partition (in this case the VIOS).
I do not have an HMC or a POWER6 system, so I cannot provide commands to check/set HEA at system level and lhea at profile level.
Hello,
POWER7 machine.
4 x 1Gbit port ethernet adapter is dedicated to vios. 8023ad etherchannel is created using those 4 ports. Etherchannel adapter is shared to lpars using SEA.
If I test network performance directly from vios partition (using iperf) I'm geting nice 4Gbit throughput. But if... (3 Replies)
hello,
what will happen if i try to move sea of my 1 vio server to standby( using chdev command), when sea of other vio server is already in standby mode? (1 Reply)
hi guys
BTW pretty new to VIO
I inherited 2 I BM Power Server - blades PS701 - One is already configured using en8
# lsdev -Cc adapter | grep ent
ent0 Available Logical Host Ethernet Port (lp-hea)
ent1 Available Logical Host Ethernet Port (lp-hea)
ent2 Available 04-20... (8 Replies)
Hi all,
I set up the following configuration on my system:
- An LPar with a virtual adapter, first one with a vlan id=703 and id port=13.
- The first adapter have to connect to a VIOS in which i configured an SEA.
So, the VA is set up on interface ent2, SEA on ent29 (by linking a... (0 Replies)
Hi Guys,
I'm getting the below error while trying to create a SEA adapter in VIOS
$ mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
... (4 Replies)
We are using sea application in SUSE linux 10, we are getting the below problem while launching the SEA
Sea is stopped with the message ' sh: /home/pub/bin/awk: cannot execute binary file' in the log window.
Anybody can help me in this issue
Thanks in Advance (1 Reply)