Hello Everyone,

I have a AIX 5.2 and saw the following entry in the error report in one of my servers.
IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION
FFDFB692 0705111911 P H sisraid0 BATTERY PACK FAILURE

Now, we're ready to replace the battery pack but I heard I need to disable the write cache first before doing any replacements. I have no idea on how to do it or check if the write cache is enabled.

Could someone please help?Smilie
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. Red Hat

SSL/TLS renegotiation DoS -how to disable? Is it advisable to disable?

Hi all Expertise, I have following issue to solve, SSL / TLS Renegotiation DoS (low) 222.225.12.13 Ease of Exploitation Moderate Port 443/tcp Family Miscellaneous Following is the problem description:------------------ Description The remote service encrypts traffic using TLS / SSL and... (2 Replies)
Discussion started by: manalisharmabe
2 Replies

2. Linux

File cache /Page cache Linux

Hi All, could any one point out any open source test-suites for "File cache" testing and as well as performance test suites for the same. Currently my system is up with Linux/ext4. Regards Manish (0 Replies)
Discussion started by: hmanish
0 Replies

3. AIX

IBM SAN storage -- cache battery

Hello, I have IBM SAN STORAGE DS4100 and one of the cache battery for the controller is dead. Suddenly the performance has been degraded and access to SAN disks ( reading and writing ) became very slow ? My query: Replacing the battery will take 6 days, so in the mean time what are the ways... (1 Reply)
Discussion started by: filosophizer
1 Replies

4. IP Networking

read/write,write/write lock with smbclient fails

Hi, We have smb client running on two of the linux boxes and smb server on another linux system. During a backup operation which uses smb, read of a file was allowed while write to the same file was going on.Also simultaneous writes to the same file were allowed.Following are the settings in the... (1 Reply)
Discussion started by: swatidas11
1 Replies

5. Linux

getting info on Cache Size, Data Cache etc..

Hi all I saw in Microsoft web site www.SysInternals.com a tool called CoreInfo from able to print out on screen the size of the Data and Instruction caches of your processor, the Locigal to Physical Processor mapping, the number of the CPU sockets. etc.. Do you know if in Linux is available a... (2 Replies)
Discussion started by: manustone
2 Replies

6. Shell Programming and Scripting

How to disable Enable/Disable Tab Key

Hi All, I have bash script, so what is sintax script in bash for Enable and Disable Tab Key. Thanks for your help.:( Thanks, Rico (1 Reply)
Discussion started by: carnegiex
1 Replies

7. Linux

Battery always 0%

Im running Ubuntu 9.04 and the battery indicator on my laptop always reads 0% no matter what. Whether im charging or discharging, the pop up says: "Computer is running on battery power Laptop battery discharging (0.0%) Battery discharge time is currently unknown" When plugged in it says... (2 Replies)
Discussion started by: Charbs
2 Replies

8. AIX

ibm san cache battery with aix

Hi All, I would like to share this incident that happened the other day. I have a question with this, https://www.unix.com/aix/64921-create-new-vg-san-rename-fs.html And I thought it's related to the above link but the problem was the ibm san 4300 cache battery was dead and I need to click... (2 Replies)
Discussion started by: itik
2 Replies

9. UNIX for Advanced & Expert Users

UBC cache vs. Metadata cache

hi, What is the difference between UBC cache and Metadata cache ? where can i find UBC cache Hits and Metadata cache Hits in hp-ux? Advanced thanx for the help. (2 Replies)
Discussion started by: sushaga
2 Replies
Login or Register to Ask a Question
UPSCODE2(8)							    NUT Manual							       UPSCODE2(8)

NAME
upscode2 - Driver for UPScode II compatible UPS equipment NOTE
This man page only documents the hardware-specific features of the upscode2 driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
This driver supports UPS equipment which can be controlled via the UPScode II protocol. This is mainly Fiskars, Powerware equipment, but also some (probably OEM'ed) products from Compaq. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): manufacturer=value Autodetection of this parameter is not possible yet (and it probably never will be). Therefore, this user-defined string accepts any name. The default is unknown. input_timeout=value The timeout waiting for a response from the UPS. Some UPS models have shown to be rather slow, resulting in frequent messages about empty responses from the UPS. If you see this, try increasing this value. output_pace=value Delay between characters sent to the UPS. This was added for completeness with the above parameter. It has not shown to be needed yet. baudrate=value The default baudrate is 1200, which is the standard for the UPScode II protocol. full_update_timer=value Number of seconds between collection of normative values. use_crlf Flag to set if commands towards to UPS need to be terminated with CR-LF, and not just CR. use_pre_lf Flag to set if commands towards to UPS need to be introduced with an LF. A Compaq T1500h is known to need this. COMMANDS
The driver supports the following commands for those UPSen that support them. The available commands are autodetected during initialization, so you should check availability with upscmd -l. o test.panel.start - Start UPS self test o test.battery.start - Start battery self test o beeper.enable - Enable UPS beeper o beeper.disable - Disable UPS beeper o shutdown.return - Shut down in 1 second and wait for power to return o shutdown.stayoff - Shut down in 1 seconds o shutdown.reboot - Shut down in 1 seconds and reboot after 1 minute o shutdown.reboot.graceful - Shut down in 20 seconds and reboot after 1 minute NOTES
The Powerware UPS models that this driver has been tested against until now have not returned a value for battery.charge. Therefore, the driver will guestimate a value based on the nominal battery min/max and the current battery voltage. AUTHOR
Havard Lygre <hklygre@online.no>, Niels Baggesen <niels@baggesen.net> SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 UPSCODE2(8)