IBM SAN storage -- cache battery


 
Thread Tools Search this Thread
Operating Systems AIX IBM SAN storage -- cache battery
# 1  
Old 05-01-2011
IBM SAN storage -- cache battery

Hello,

I have IBM SAN STORAGE DS4100 and one of the cache battery for the controller is dead. Suddenly the performance has been degraded and access to SAN disks ( reading and writing ) became very slow ?

My query: Replacing the battery will take 6 days, so in the mean time what are the ways to speed up the access to the disks ?

1) Could I move the Array from the failed battery controller B to controller A ? Does it need to have multipath MPIO installed and configured ?

2) disable the write cache and enable write-cache working without battery ==> Will it improve the performance ?

3) powering off SAN Storage completely and restarting it ? ==> will there be any implications ?


Code:
SUMMARY------------------------------
   Number of controllers: 2
   Number of arrays: 3
   Total number of logical drives (includes an access logical drive): 5 of 1024 used
      Number of standard logical drives: 4
      Number of access logical drives: 1
   Number of drives: 11
   Supported drive types: Fibre (11)
   Total hot spare drives: 0
      Standby: 0
      In use: 0
   Access logical drive: LUN 31 (see Mappings section for details)
   Default host type: AIX (Host type index 6)
   Current configuration
      Firmware version: 06.12.16.00
      NVSRAM version: N1722F600R912V05
   Pending configuration
      Staged firmware download supported?: Yes
      Firmware version: None
      NVSRAM version: None
      Transferred on: None
   NVSRAM configured for batteries?: Yes
   Start cache flushing at (in percentage): 80
   Stop cache flushing at (in percentage): 80
   Cache block size (in KB): 4
   Media scan frequency (in days): 30
   Failover alert delay (in minutes): 5
   Feature enable identifier: 3034383037003834333831004133365E
   Storage Subsystem worldwide name (ID): 600A0B800016E56E000000004133366F


ENCLOSURES------------------------------
 Drive/Controller Enclosure 0 Overall Component Information
      Drive technology: Fibre channel
      Minihub data rate mismatch: No
      Part number: PN 24P8129     
      Serial number: SN 13G6078     
      Vendor: VN IBM     
      Date of manufacture: August 1, 2004
      Enclosure path redundancy: OK
      Fan canister
         Location: Left
         Status: Optimal
      Fan canister
         Location: Right
         Status: Optimal
      Battery status: Optimal
         Location: Controller in slot A
         Age: 858 day(s)
         Days until replacement: 311 day(s)
      Battery status: Removed
         Location: Controller in slot B
         Age: 1055 day(s)
         Days until replacement: 114 day(s)
.....
.....
.....
DETAILS
   Logical Drive name: oraappvg
      Logical Drive ID: 60:0a:0b:80:00:16:e5:6e:00:00:13:1a:41:87:1f:12
      Subsystem ID (SSID): 0
      Status: Optimal 
      Drive type: Fibre Channel
      Enclosure loss protection: No
      Preferred owner: Controller in slot A
      Current owner: Controller in slot A
      Capacity: 135.732 GB
      RAID level: 5
      Segment size: 64 KB
      Modification priority: High
      Associated array: 1
      Read cache: Enabled
      Write cache: Enabled (currently suspended)
      Write cache without batteries: Disabled
      Write cache with mirroring: Enabled (currently suspended)
      Flush write cache after (in seconds): 10.00
      Cache read ahead multiplier: 1
      Enable background media scan: Enabled
      Media scan with redundancy check: Disabled

ibm san cache battery with aix
create a new VG on SAN and rename FS
developerWorks : IBM Systems : IBM System Storage : DS4700 Battery Cache affecting ...
IBM System Storage DS3000 cache batteries not covered under warranty
DS4000 cache battery expiration

Quote:
http://www.tek-tips.com/viewthread.cfm?qid=1493007&page=41
From the storage manager you have to findout the arrays which are pointing to that suspected controller ( say Controller-B) against which the battery is failed.

Now you have to move the arrays from controller-B to Controller-A and make sure while doing this there is no I/O with the disks in the stroage.


It takes little bit of time to move the arrays from the contr-B to contr-A. After this, you have to disable the controller through storage manager. After doing this you can take that module out from DS4300 and replace the battery.


After change the battery, you please put it back into storage DS4300 unit and enable the controller.


After enable the controller, you have to move all the arrays back which you previoulsy moved from Contr.-B to Contr.-A


The Storage Manager Help is pretty staright forward in which you can see the step by step process to change the battery.
---------- Post updated at 01:43 PM ---------- Previous update was at 11:47 AM ----------

I think Multipath is not enabled on the system even though HACMP is installed

# lsdev -Cc disk
hdisk0 Available 1S-08-00-8,0 16 Bit LVD SCSI Disk Drive
hdisk1 Available 1S-08-00-9,0 16 Bit LVD SCSI Disk Drive
hdisk2 Available 1V-08-02 1722-600 (600) Disk Array Device
hdisk3 Available 1D-08-02 1722-600 (600) Disk Array Device
hdisk4 Available 1V-08-02 1722-600 (600) Disk Array Device
hdisk5 Available 1D-08-02 1722-600 (600) Disk Array Device
# lspv
hdisk1 0059da1d0ddcf5b9 rootvg active
hdisk2 0059da1d0d864640 oraappvg active
hdisk3 0059c87d0d80db98 oradbvg
hdisk4 0059c87d7662aa73 None
hdisk0 0059da1d968b4e5f rootvg active
hdisk5 0059c87d27ac212f oradbvg
# lspath
Enabled hdisk0 scsi0
Enabled hdisk1 scsi0

Last edited by filosophizer; 05-01-2011 at 05:20 PM..
# 2  
Old 05-05-2011
The problem was solved by disabling the read and write cache for the disks under the controller which had the failed battery.

I think it could have been solved also by moving the disks from Controller B to controller A , but this I am not sure if you don't have MPIO ( Multi path I/O ) how will it behave ?

I will attach few screen shots later.

thanks
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. AIX

IBM AIX - SAN Storage DS4300 issue

Hi, This is follow up to the post https://www.unix.com/aix/233361-san-disk-appearing-double-aix.html When I connected Pseries Machine HBA Card ( Dual Port ) directly to the SAN Storage DS4300 , I was able to see Host Port Adapter WWN numbers , although I was getting this message... (2 Replies)
Discussion started by: filosophizer
2 Replies

2. AIX

IBM SAN TO SAN Mirroring

Has anyone tried SAN to SAN mirroring on IBM DS SAN Storage. DS5020 mentions Enhanced Remote Mirror to multi-LUN applications I wonder if Oracle High availibility can be setup using Remote Mirror option of SAN ? (1 Reply)
Discussion started by: filosophizer
1 Replies

3. AIX

IBM SAN STORAGE HOT SPARE DISK

Hello, I have DS4000 IBM SAN Storage ( aka FastT Storage ) One of my disks has failed and I had a hot spare disk covering all the arrays. As the disk failed, immediately the hotspare disk took over the failed disk ( see the JPEG in the attachment ) My Question: How can I make the hotspare... (1 Reply)
Discussion started by: filosophizer
1 Replies

4. AIX

Help: Disable write cache for battery replacement

Hello Everyone, I have a AIX 5.2 and saw the following entry in the error report in one of my servers. IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION FFDFB692 0705111911 P H sisraid0 BATTERY PACK FAILURE Now, we're ready to replace the battery pack but I heard I need to... (0 Replies)
Discussion started by: blakedaddy
0 Replies

5. Solaris

Cannot see the IBM SAN storage

HI all, I had recently change the Server storage from EMC to the IBM SAN. but after the configuration, the IBM success to see the server HBA port and successfully assign a LUN for the server. When i go to the server, and restarted it. i use the "format" command to check, but din see any... (1 Reply)
Discussion started by: SmartAntz
1 Replies

6. AIX

MPIO RDAC IBM SAN STORAGE DS4700 ?

Hello, I have AIX 6.1 with TL 4 and it is connected to IBM SAN STORAGE DS4700 After assigning some disks from SAN to AIX, I can see the disks in my AIX as hdisk2 Available 05-00-02 MPIO Other DS4K Array Disk hdisk3 Available 05-00-02 MPIO Other DS4K Array Disk But it should... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. AIX

IBM SAN Storage DS4700 - Copy Mirror Flashcopy

Hello, Does anyone know how to copy SAN Storage logical disks from IBM TotalStorage Software. I have a SAN Logical Disk of 200GB mounted on my AIX LPAR_1 via fibre channel fcs0 I would like to make an exact copy of the SAN Logical Disk from IBM totalStorage and mount it on AIX LPAR_2 ... (4 Replies)
Discussion started by: filosophizer
4 Replies

8. AIX

IBM FastT600 SAN - RAID 5 Storage Manager Client v08.33.G5.03 - Recovery?

To summarize the problem: The "IBM FastT Storage Manager Client v8" shows that our Disk Farm is arranged into 6 logical drives each in a RAID 5 configuration. This software also shows that 5 of the 6 logical drives (from Disk Farm) are in a error state: "Failed Logical Drive - Drive Failure".... (1 Reply)
Discussion started by: aix-olympics
1 Replies

9. AIX

ibm san cache battery with aix

Hi All, I would like to share this incident that happened the other day. I have a question with this, https://www.unix.com/aix/64921-create-new-vg-san-rename-fs.html And I thought it's related to the above link but the problem was the ibm san 4300 cache battery was dead and I need to click... (2 Replies)
Discussion started by: itik
2 Replies
Login or Register to Ask a Question