10 More Discussions You Might Find Interesting
1. AIX
I have a broken PV in a VIO VG that's used to support client LPARs using LVs. On the client LPAR, I reduced all PVs from the relevant client VG and thus deleted it. I.e. there is no client LPAR using the VIO VG. Yet when I try to reducevg the VIO VG, it complains that the LV hosted on the PV is... (2 Replies)
Discussion started by: maraixadm
2 Replies
2. AIX
I know the VIOs are generally to be treated as an appliance and one should never drop down to oem_setup_env. In reality however, oem is a very useful tool to get the job done. So that leads me into the question of using the Chef client on a VIO.
Currently a big push to manage all our *nix... (4 Replies)
Discussion started by: RecoveryOne
4 Replies
3. AIX
Hi,
I am facing an issue in vio server. When I run
bosboot -ad /dev/hdisk0
I am getting an error
trustchk: Verification of attributes failed: /usr/sbin/bootinfo
: accessauths
regards,
vjm
Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies
4. AIX
Hi
In my vio server I have the below output
$ lsvopt | grep -i SAPSITGS
sapsitgs_cdrom TL12UP.iso 3182
In my vio client lpar I have the below output
root@sapsitgs:/ # lsdev -Cc cdromcd0 Available Virtual SCSI Optical Served by VIO Server
cd1... (1 Reply)
Discussion started by: newtoaixos
1 Replies
5. AIX
Hi,
I would like to know installing vio server on local disk and mirroring rootvg,
if I am creating AIX VIO CLIENT(lpar),
and any of single local hard disk failuare.
will it affect lpars? will lpars able to boot.
what needs to be done? (1 Reply)
Discussion started by: manoj.solaris
1 Replies
6. AIX
Hi
In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID.
Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies
7. AIX
Hi
im logged in to the vio servers now.
when i give
# lspv | wc -l
i get the count as 6246
how will i know if a lun has been already mapped to a vio client or it is left free without mapping to any of the vio client ? (1 Reply)
Discussion started by: newtoaixos
1 Replies
8. AIX
Hi
I am facing very strange issue on my vio server 5 vio clients are confgured, now I am to connect 3 vio client , i am unable to connect 2 vio client my ip address,subnet mask,gateway is correct.
i have rebooted and reconfigured the ip address, but issue is persists.
Kindly suggest how to... (0 Replies)
Discussion started by: manoj.solaris
0 Replies
9. AIX
Hi,
I am having single p series blade with Single Physcial CPU with dual core,
on that vio server is installed, I have created vio client allocate 0.9 each cpu , now when I am running prtconf command on vio client it is showing "2" no of processor,
My query using which command it will... (1 Reply)
Discussion started by: manoj.solaris
1 Replies
10. AIX
Hi,
I would like to reboot vio client but I am not able to access vio client(I am not able to get putty) , I am able to get putty of vio server,
is there any command by using which from vio server I can reboot vio client? (3 Replies)
Discussion started by: manoj.solaris
3 Replies