Sponsored Content
Full Discussion: Performances with RAID 5
Operating Systems Solaris Performances with RAID 5 Post 94767 by reborg on Tuesday 3rd of January 2006 10:59:40 PM
Old 01-03-2006
A basic rule of thumb is:

Never implement raid 5 in software. If your hardware doesn't support it it's not worth using because of the cost of parity calculation as ppointed out in an earlier post. I is much better to go with a striped & mirorred strategy for performance. The cost in hardware is much much less for RAID5 and so it becomes viable.
 

9 More Discussions You Might Find Interesting

1. AIX

ssa performances

Helo: We updated form AIX 4.3.3 to AIX 5.1-7 and after this we spent more than double time in read from external disks. Aparently the ssa cards microcode is at last level and all the ptf and apars are instaled. Out backups expent more than double time, but curiously in read only, if we write in... (0 Replies)
Discussion started by: Javier Gutierre
0 Replies

2. Linux

grep -f CPU performances

Hi I would like to thank you all for this excellent forum. Today i tried to compare two files and i get some problem with it. I have two files and i want to get all the data that match the first file like this File1 (pattern file) ___________________________ 9007 9126 9918 9127 ... (6 Replies)
Discussion started by: tafil
6 Replies

3. UNIX for Advanced & Expert Users

File alignment and performances... (difficult)

Hello ! I will use my best english possible to explain my objective. I'm french so pardon for the lack of precision... So, what i would like to do in shell script (but you will possibly answer ''not possible in script'' have to use low level langage or something like that) is described below.... (3 Replies)
Discussion started by: Gnaag
3 Replies

4. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

5. Solaris

implementing RAID 1 from RAID 5

Dear ALl, I have a RAID 5 volume which is as below d120 r 60GB c1t2d0s5 c1t3d0s5 c1t4d0s5 c1t5d0s5 d7 r 99GB c1t2d0s0 c1t3d0s0 c1t4d0s0 c1t5d0s0 d110 r 99GB c1t2d0s4 c1t3d0s4 c1t4d0s4 c1t5d0s4 d8 r 99GB c1t2d0s1 c1t3d0s1... (2 Replies)
Discussion started by: jegaraman
2 Replies

6. Solaris

Creation of Raid 01 and Raid 10

Hello All, I have read enough of texts on Raid 01 and Raid 10 on solaris :wall: . But no-where found a way to create them using SVM. Some one pls tell me how to do or Post some link if that helps. TIA Curious solarister (1 Reply)
Discussion started by: Solarister
1 Replies

7. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

8. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

9. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies
SENSORS-DETECT(8)					      System Manager's Manual						 SENSORS-DETECT(8)

NAME
sensors-detect - detect hardware monitoring chips SYNOPSIS
sensors-detect DESCRIPTION
sensors-detect is an interactive program that will walk you through the process of scanning your system for various hardware monitoring chips, or sensors, supported by libsensors(3), or more generally by the lm_sensors tool suite. sensors-detect will look for the following devices, in order: o Sensors embedded in CPUs, south bridges and memory controllers. o Sensors embedded in Super I/O chips. o Hardware monitoring chips accessed through ISA I/O ports. o Hardware monitoring chips reachable over the SMBus or more generally any I2C bus on your system. As the last two detection steps can cause trouble on some systems, they are normally not attempted if the second detection step led to the discovery of a Super I/O chip with complete hardware monitoring features. However, the user is always free to ask for all detection steps if so is his/her wish. This can be useful if a given system has more than one hardware monitoring chip. Some vendors are known to do this, most notably Asus and Tyan. WARNING
sensors-detect needs to access the hardware for most of the chip detections. By definition, it doesn't know which chips are there before it manages to identify them. This means that it can access chips in a way these chips do not like, causing problems ranging from SMBus lockup to permanent hardware damage (a rare case, thankfully.) The authors made their best to make the detection as safe as possible, and it turns out to work just fine in most cases, however it is impossible to guarantee that sensors-detect will not lock or kill a specific system. So, as a rule of thumb, you should not run sensors- detect on production servers, and you should not run sensors-detect if can't afford replacing a random part of your system. Also, it is recommended to not force a detection step which would have been skipped by default, unless you know what you are doing. SEE ALSO
sensors(1), libsensors(3) AUTHOR
Frodo Looijaard and Jean Delvare lm-sensors 3 December 2008 SENSORS-DETECT(8)