Sponsored Content
Full Discussion: Mirrored disk.....
Operating Systems AIX Mirrored disk..... Post 93788 by b_manu78 on Thursday 22nd of December 2005 05:29:53 AM
Old 12-22-2005
I can help you a bit...

take the output of lsvg -l rootvg...and with bakunin's reply u can find out the file systems which are having 2 PPs for their LPs.


Now search for those file systems(which are having 2 PPs for their LPs) on each HDD in that VG. If you find the File system. that PV is in the mirroring.
 

10 More Discussions You Might Find Interesting

1. HP-UX

Number of Disk Mirrored in HP-UX

In HP-UX 11.00 How can i check if there are disks mirrored (2 Replies)
Discussion started by: cgege
2 Replies

2. UNIX for Dummies Questions & Answers

Creating create mirrored disk files systems using mkfs command

What is the correct mkfs syntax to create mirrored disk files systems? I need to make the file system 20gb. For example: machine# mkfs -F ufs /dev/md/dsk/d40 size not specified ufs usage: mkfs special size(sectors) \ -m : dump fs cmd line used to make this partition -V : print this... (4 Replies)
Discussion started by: GLJ@USC
4 Replies

3. UNIX for Dummies Questions & Answers

Solaris 10 not booting with mirrored disk

Hi all, I have a V490 running with Solaris 10. The OS disk was mirrored. I wanted to break the mirror, boot with the secondary mirror, and re-mirror the OS with a new disk. This is what I did, detached the metadevices of the secondary mirror disk (disk 1) metaclear-ed the metadevices,... (1 Reply)
Discussion started by: nitinp82
1 Replies

4. Solaris

Remove os mirrored disk Solaris 10

Hello once again seeking your help, I have a mirrored disk and need to unmirror it to mount it as a new file system (/export) but could not find the correct steps to do it with out affecting the original disk. can anybody point me out on how to get this done. Thanks!! (3 Replies)
Discussion started by: AQG
3 Replies

5. UNIX for Advanced & Expert Users

how to create multiple-boot system with disks mirrored(RAID1+0) and disk alone

I have a HP proliant ML 570 G3 with two 146GB disk drives mirrored(RAID1+0) windows server 2003 was installed on that disk. I will add a disk.(scsi 300GB) I will install Linux on that additional disk. I want to create multiple-boot system. Is it possible? I wanna know how to create... (0 Replies)
Discussion started by: lifegeek
0 Replies

6. Solaris

Are my disks mirrored ?

# metastat d1: Mirror Submirror 0: d11 State: Okay Submirror 1: d12 State: Okay Pass: 1 Read option: roundrobin (default) Write option: parallel (default) Size: 14582208 blocks (7.0 GB) d11: Submirror of d1 State: Okay Size: 14582208 blocks... (2 Replies)
Discussion started by: Exposure
2 Replies

7. Solaris

Boot from Mirrored disk

So I have mirrored disk already set up from c1t0d0 to c1t1d0. Is there some special procedures that I need to do before I do and then try to boot from the mirrored disk? I am using a V490 if that helps... (7 Replies)
Discussion started by: drew_1980
7 Replies

8. AIX

How to extend mirrored VG?

Hi all, I need to extend a lv, but unfortunately I do not have enough space on my mirrored Volume group. I've planned to add 2 more disks to this vg (for mirroring) But ... what's the next steps to extend my lv using these 2 disks with a valid mirroring ? 1. extendvg myvg disk1 disk2... (3 Replies)
Discussion started by: unclefab
3 Replies

9. Solaris

Need help replacing a mirrored boot disk

I have a v480 with a mirrored boot disk c1t0 and c1t1. The drives themselves don't show a failure but the mirror's need maintenance. This is my plan for replacing the drive. I would love feedback to point out what I"m missing or where my steps are incorrect. Two things I believe I'm... (3 Replies)
Discussion started by: pcoffey
3 Replies

10. Red Hat

Booting 2nd mirrored boot disk

Hi guys, thanks for helping out. If you have two boot disk mirrored and your primary boot disk fails, how will you boot the system from the second disk? Thank you very much for your assistance on this matter. Arrey (5 Replies)
Discussion started by: cjashu
5 Replies
pfto(7) 						 Miscellaneous Information Manual						   pfto(7)

NAME
pfto - Powerfail Timeout DESCRIPTION
HP-UX SCSI disk device drivers have a timeout facility that detects non-responding disks. VxVM uses this mechanism in its Powerfail Time- out (pfto) feature. You can specify a timeout value for individual VxVM disks using the vxdisk command (see the EXAMPLES section below). If a disk fails to respond in the specified timeout period, the driver receives a timer interrupt. pfto values are persistent across reboots, that is, after the pfto value is set, it remains in effect until you explicitly change it. If dynamic multipathing is enabled, the pfto value set on a disk applies to each path of a multipath disk device. The pfto value is in seconds. If pfto is not specified, or is zero, the timeout period is 30 seconds. Both the vxdisk and vxprint commands display the current pfto value for a disk. EXAMPLES
Use the following command to set the value of pfto to 30 seconds on disk01: vxdisk -g rootdg set disk01 pfto=30 Use either of the following commands to display the pfto value on the VxVM disk disk01: vxdisk list disk01 vxprint -l disk01 EXIT CODES
Setting the pfto value on a non-VxVM disk returns an error. SEE ALSO
vxdisk(1M), vxprint(1M) VxVM 5.0.31.1 24 Mar 2008 pfto(7)