11-11-2005
thank you sir...
two drives = no automated solution in drive failure
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
Hello,
We are using Solstice Disk Suite on Solaris 2.7.
We want to add two striped volume with six disks.
On each disk, we take a slice and we create the stripe.
That I want to know :
Is it necessary to add two replicas on the same slice on the new disks, as made before on the others... (1 Reply)
Discussion started by: christophe
1 Replies
2. Solaris
Good morning,
I have Solstice disk suite installed on my server.
One disk broke so I sostitute it.
A replica was present on this disk.
I had delete and then recreate it with commands metadb -d and metadb -a.
Now when I inquire for the status of replicas I see this:
stp11# metadb -i
... (2 Replies)
Discussion started by: bonovox
2 Replies
3. Solaris
hi all
i am very new to solaris...i am trying configure raid 0 in my ultrascsi box which is having 6 sun36GB hard disks. I have created 4 state database replicas in the following slices /dev/dsk/c1t1d0s7 /dev/dsk/c1t2d0s7 /dev/dsk/c1t3d0s7 and /dev/dsk/c1t4d0s7. i could not use any other... (7 Replies)
Discussion started by: kingston
7 Replies
4. Solaris
At a new job, I've inherited a handful of Solaris 10 SunFire V240 servers.
I noticed that the metadevices are not consistent, in a way that I've not seen before....
internal mirrored disks:
metadevice d60 has c1t0d0s6 as submirror 0 (d61) and c1t1d0s6 as submirror 1 (d62)
metadevice... (1 Reply)
Discussion started by: Max Power
1 Replies
5. Solaris
Hi all,
I recently started exploring Solaris 10.
I am testing metadevices now.
I have been reading about the state databases here: 6.State Database (Overview) (Solaris Volume Manager Administration Guide) - Sun Microsystems
So I created 3 metadbs on 2 slices (6 in total; c1t1d0s3... (3 Replies)
Discussion started by: deadeyes
3 Replies
6. Solaris
Hey all!
I was hoping someone knew anything about this one...
I know with Solaris Volume Manager the default Database Replica size is 8192 blocks (4MB approximately)
Now I know you can increase this amount but is there any point?
The reason I am asking this is that I've setup mirroring on... (2 Replies)
Discussion started by: Keepcase
2 Replies
7. Programming
Hello,
I have some Fortran code that is providing the following error:
At line 1165 of lapc_shells_2.f
Fortran runtime error: Insufficient data descriptors in format after reversion
Here are the lines just above and including 1165:
WRITE (*,"('ATTEMPTING TO READ PLATE... (1 Reply)
Discussion started by: jm4smtddd
1 Replies
8. Solaris
I lost my system volume in a power outage, but fortunately I had a dual boot and I could boot into an older opensolaris version and my raidz2 7 drive pool was still fine. I even scrubbed it, no errors. However, the older os has some smb problems so I wanted to upgrade to opensolaris11. I... (3 Replies)
Discussion started by: skk
3 Replies
9. UNIX for Advanced & Expert Users
Hi All,
I am using svnnotify (which is available on net) script to send svn commit notification.
Everything was working fine up to yesterday but from yesterday i started seeing error.
29CD01FCE44 7228 Thu Apr 5 11:11:51 apache@vm0001.host.com
(host mail.mailserver.com said: 452... (6 Replies)
Discussion started by: vishal_vsh1
6 Replies
10. Shell Programming and Scripting
I'm trying to crudely hack my way through some data processing.
I have file.txt with around 17,000 lines like this:
ACYPI002690-PA.aa.afa.afa.trim_phyml_tree_fullnames_fullhomolog.txt 3 72 71
ACYPI002690-PA.aa.afa.afa.trim_phyml_tree_fullnames_fullhomolog.txt 97 111 71... (1 Reply)
Discussion started by: pathunkathunk
1 Replies
LEARN ABOUT SUSE
ocf_pacemaker_healthsmart
OCF_PACEMAKER_HEALTH(7) Pacemaker Configuration OCF_PACEMAKER_HEALTH(7)
NAME
ocf_pacemaker_HealthSMART - SMART health status
SYNOPSIS
OCF_RESKEY_state=string OCF_RESKEY_drives=string OCF_RESKEY_temp_lower_limit=string OCF_RESKEY_temp_upper_limit=string
HealthSMART [start | stop | monitor | meta-data | validate-all]
DESCRIPTION
Systhem health agent that checks the S.M.A.R.T. status of the given drives and updates the #health-smart attribute.
SUPPORTED PARAMETERS
OCF_RESKEY_state = string [/var/run//health-smart-{OCF_RESOURCE_INSTANCE}.state]
State file
Location to store the resource state in.
OCF_RESKEY_drives = string [sda]
Drives to check
The drives to check as a SPACE separated list. Enter only the part after the "/dev/" i.e. "sda". At the moment /dev/sda is hard coded.
Sorry.
OCF_RESKEY_temp_lower_limit = string [0]
Lower limit for the temperature of the drive(s)
Lower limit of the temperature in deg C of the drive(s). Below this limit there status will be red. The yellow limit is 5 deg C more
than this value.
OCF_RESKEY_temp_upper_limit = string [60]
Upper limit for red smart attribute
Upper limit of the temperature if deg C of the drives(s). If the drive reports a temperature higher than this value the status of
#health-smart will be red. The yellow limit is 5 deg C below this value.
AUTHOR
Andrew Beekhof <andrew@beekhof.net>
Author.
Pacemaker Configuration 07/05/2010 OCF_PACEMAKER_HEALTH(7)