01-25-2001
I have a Unix based system running my POS (Point of sale) system that uses two 4.1 gig hard drives. I use the
./diskcopy
command to mirror master to Backup
My problem is 4.1 gig hard drives are no longer available new so I need to move to a larger cap drive but for my command to work the 2 drives must be physically the same.
What should do to mirror (os & data) to a larger physical drve?
Are there util programs to do this?
Possible 11th user of UNIX
9 More Discussions You Might Find Interesting
1. Solaris
I have just been assigned the task of upgrading to a larger disk on a e250; however, I am use to working on Linux and x86 hardware. I would be very appreciative if someone could inform me on how this procedure can be done safely.
To begin with, the e250 has a 18 Gig primary scsi disk and a 18... (3 Replies)
Discussion started by: cstovall
3 Replies
2. Shell Programming and Scripting
Hi All,
I am trying to grab a term which is just smaller and larger than the assigned value using the below code. But there seems to be some problem. The value i assign is 25 so i would expect it to output a smaller value to be 20 instead of 10 and 20 and larger value to be 30 instead of 30 and... (3 Replies)
Discussion started by: Raynon
3 Replies
3. AIX
Hi,
How do I mirror an external scsi vg to one hdisk san? The vg has multiple hdisks and the san hdisk has only one.
Is this possible or do I need to create the same hdisks as the scsi? What I meant is, if the scsi vg has 10 hdisk then I need to create also 10 hdisk of san with the same... (6 Replies)
Discussion started by: itik
6 Replies
4. Solaris
I've looked a little but haven't found a solid answer, assuming there is one.
What's better, hardware mirroring or ZFS mirroring? Common practice for us was to use the raid controllers on the Sun x86 servers. Now we've been using ZFS mirroring since U6. Any performance difference? Any other... (3 Replies)
Discussion started by: Lespaul20
3 Replies
5. Solaris
Hi ,
I am new to SVM .when i try to learn RAID 1 , first they are creating two RAID 0 strips through
metainit d51 1 1 c0t0d0s2
metainit d52 1 1 c1t0d0s2
In the next step
metainit d50 -m d51
d50: Mirror is setup
next step is
metaattach d50 d52
d50 : submirror d52 is... (7 Replies)
Discussion started by: vr_mari
7 Replies
6. AIX
hello folks,
I have a 300GB ROOTVG volume groups with one filesystem /backup having 200GB allocated space
Now, I cannot alt disk clone or mirrorvg this hdisk with another smaller disk. The disk size has to be 300GB; I tried alt disk clone and mirrorvg , it doesn't work. you cannot copy LVs as... (9 Replies)
Discussion started by: filosophizer
9 Replies
7. HP-UX
what is the difference between DRD and Root Mirror Disk using LVM mirror ? (3 Replies)
Discussion started by: maxim42
3 Replies
8. Shell Programming and Scripting
Hi,
I am fairly new to Unix scripting. We are running Solaris 5.10.
I have the following question: Assume a text file with one text
column, followed by 2 integer columns.
How would I generate a script or, preferably, a command that will output
the rows in which the value of the third... (6 Replies)
Discussion started by: QZ1
6 Replies
9. Shell Programming and Scripting
I would like the window that this opens to be larger.
Can it be modified to do so?
Thanks.
#!/usr/bin/env python3
# Text snippets are in /home/andy/.config/snippet_paste/
import os
import subprocess
home = os.environ
directory = home+"/.config/snippet_paste"
if not... (4 Replies)
Discussion started by: drew77
4 Replies
LEARN ABOUT DEBIAN
array-info
array-info(1) array-info(1)
NAME
array-info - check the status of a HP (Compaq) SmartArray controller
SYNOPSIS
array-info -d array_device_path [-a|-l|-A|-c|-s|-L|-h]
DESCRIPTION
Array-info is a command line tool to retrieve informations and logical drives status from several RAID controllers (currently HP Compaq IDA
and CISS and MD). It displays informations about the firmware version, Rom revision, number of physical and logical drives on the con-
troller, aswell as the fault tolerance, size, number of physical disks and status for each logical drive.
OPTIONS
--device | -d
Path to array device, e.g. /dev/ida/c0d0 or /dev/cciss/c0d1
--all-drives | -a
Show informations about all drives
--logical drive | -l
Show informations about selected logical drive
--show-ctrl | -c
Show informations about controller
--show-logical | -L
Show informations about logical drives
--show-physical | -p
Show physical device informations
--show-status | -s
Show status of logical drives
--show-all | -A
Show all informations
--version | -V
Show version
-h Show help about options
COPYRIGHT
This manual page was written by Raphael Pinson <<raphink@ubuntu.com>>. Permission is granted to copy, distribute and/or modify this docu-
ment under the terms of the GNU General Public License, Version 2 or any later version published by the Free Software Foundation.
2006-12-15 array-info(1)