Sponsored Content
Full Discussion: PowerMac 4400 YLD 3.0
UNIX Standards and Benchmarks UNIX & LINUX Benchmarks (Version 3.11) Linux Benchmarks PowerMac 4400 YLD 3.0 Post 80310 by clemare on Friday 5th of August 2005 11:07:38 AM
Old 08-05-2005
PowerMac 4400 YLD 3.0

CPU/Speed: PowerPC 603ev 200Mhz
Ram: 92M EDO Ram
Motherboard: Apple
Bus: 2 PCI
Cache: L1 32k and L2 256k
Controller: ATA
Disk: 2GB ATA
Load: 1 user, running httpd, Xwin, various daemons
Kernel: Linux 2.4.22-2f
Kernel ELF?: ???
pgms: gcc versión 3.2.2 20030217 (Yellow Dog Linux 3.0 3.2.2-2a);
options = none

==============================================================

BYTE UNIX Benchmarks (Version 3.11)
System -- Linux localhost.localdomain 2.4.22-2f #1 Sun Nov 9 16:49:49 EST 2003 ppc ppc ppc GNU/Linux
Start Benchmark Run: vie ago 5 09:14:05 CLT 2005
1 interactive users.
Dhrystone 2 without register variables 436566.1 lps (10 secs, 6 samples)
Dhrystone 2 using register variables 436389.3 lps (10 secs, 6 samples)
Arithmetic Test (type = arithoh) 481163.5 lps (10 secs, 6 samples)
Arithmetic Test (type = register) 78240.5 lps (10 secs, 6 samples)
Arithmetic Test (type = short) 72523.5 lps (10 secs, 6 samples)
Arithmetic Test (type = int) 78069.3 lps (10 secs, 6 samples)
Arithmetic Test (type = long) 78259.4 lps (10 secs, 6 samples)
Arithmetic Test (type = float) 39815.8 lps (10 secs, 6 samples)
Arithmetic Test (type = double) 32652.2 lps (10 secs, 6 samples)
System Call Overhead Test 120294.5 lps (10 secs, 6 samples)
Pipe Throughput Test 79124.3 lps (10 secs, 6 samples)
Pipe-based Context Switching Test 42842.7 lps (10 secs, 6 samples)
Process Creation Test 422.8 lps (10 secs, 6 samples)
Execl Throughput Test 152.7 lps (9 secs, 6 samples)
File Read (10 seconds) 308831.0 KBps (10 secs, 6 samples)
File Write (10 seconds) 14400.0 KBps (10 secs, 6 samples)
File Copy (10 seconds) 4660.0 KBps (10 secs, 6 samples)
File Read (30 seconds) 309485.0 KBps (30 secs, 6 samples)
File Write (30 seconds) 14083.0 KBps (30 secs, 6 samples)
File Copy (30 seconds) 4575.0 KBps (30 secs, 6 samples)
C Compiler Test 64.0 lpm (60 secs, 3 samples)
Shell scripts (1 concurrent) 241.0 lpm (60 secs, 3 samples)
Shell scripts (2 concurrent) 127.0 lpm (60 secs, 3 samples)
Shell scripts (4 concurrent) 65.0 lpm (60 secs, 3 samples)
Shell scripts (8 concurrent) 33.0 lpm (60 secs, 3 samples)
Dc: sqrt(2) to 99 decimal places 6581.2 lpm (60 secs, 6 samples)
Recursion Test--Tower of Hanoi 5350.4 lps (10 secs, 6 samples)


INDEX VALUES
TEST BASELINE RESULT INDEX

Arithmetic Test (type = double) 2541.7 32652.2 12.8
Dhrystone 2 without register variables 22366.3 436566.1 19.5
Execl Throughput Test 16.5 152.7 9.3
File Copy (30 seconds) 179.0 4575.0 25.6
Pipe-based Context Switching Test 1318.5 42842.7 32.5
Shell scripts (8 concurrent) 4.0 33.0 8.2
=========
SUM of 6 items 107.9
AVERAGE 18.0
 

4 More Discussions You Might Find Interesting

1. IP Networking

How to Network a PowerMac & a PC

Ok, so I'm new to the Unix thing, but I've got 2 old computers that are useless for much now & I want to install some flavor of Unix on both. One is a PowerMac & one is a NEC PC (200 MHz). Is there a certain flavor of Unix (or Linux) that I can install on both so they will communicate? ... (2 Replies)
Discussion started by: Galaxy_Girl
2 Replies

2. OS X (Apple)

Mac OS X And The PowerMac G5

When they say that the G5 is the faster (more faster) than any UNIX Workstation that means Dual Processor Workstations right? (Stupid Question, I know) I heard theres one Super Super clusternode in a research and varsity joint in the US that will have over 1200 G5's chips in it? Medical,... (2 Replies)
Discussion started by: RedVenim
2 Replies

3. UNIX Benchmarks

Early PowerMac G5

Hardware Overview: Model Name: Power Mac G5 Model Identifier: PowerMac7,2 Processor Name: PowerPC 970 (2.2) Processor Speed: 1.8 GHz Number Of CPUs: 2 L2 Cache (per CPU): 512 KB Memory: 1.5 GB Bus Speed: 900 MHz Boot ROM Version:... (0 Replies)
Discussion started by: tnorth
0 Replies

4. Filesystems, Disks and Memory

Some question about SAN on HP 4400 EVA

Good morning. For testing purpose i have buy a SAN DISK SHELF i need now a controller(hsv300) and a switch SAN Is my first SAN so i'm a little confused about cables. For testing we use an old rx2600 hp server the adapter is HP A6795AX A6795-62001 Some fast questions: i need an fc/fc cable... (7 Replies)
Discussion started by: Linusolaradm1
7 Replies
volcheck(1)							   User Commands						       volcheck(1)

NAME
volcheck - checks for media in a drive and by default checks all floppy media SYNOPSIS
volcheck [-v] [-i secs] [-t secs] pathname DESCRIPTION
The volcheck utility tells Volume Management to look at each dev/pathname in sequence and determine if new media has been inserted in the drive. The default action is to volcheck all checkable media managed by volume management. OPTIONS
The following options are supported: -i secs Set the frequency of device checking to secs seconds. The default is 2 seconds. The minimum frequency is 1 second. -t secs Check the named device(s) for the next secs seconds. The maximum number of seconds allowed is 28800, which is 8 hours. The fre- quency of checking is specified by -i. There is no default total time. -v Verbose. OPERANDS
The following operands are supported: pathname The path name of a media device. EXAMPLES
Example 1: A sample of the volcheck command. The following example example% volcheck -v /dev/diskette /dev/diskette has media asks Volume Management to examine the floppy drive for new media. The following example example% volcheck -i 2 -t 600 /dev/diskette1 & asks Volume Management if there is a floppy in the floppy drive every 2 seconds for 600 seconds (10 minutes). FILES
/dev/volctl Volume Management control port ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWvolu | +-----------------------------+-----------------------------+ SEE ALSO
eject(1), volcancel(1), volmissing(1) rmmount(1M), vold(1M), rmmount.conf(4), vold.conf(4), attributes(5), volfs(7FS) WARNINGS
Due to a hardware limitation in many floppy drives, the act of checking for media causes mechanical action in the floppy drive. Continu- ous polling of the floppy drive will cause the drive to wear out. It is recommended that polling the drive only be performed during periods of high use. SunOS 5.10 21 Feb 1997 volcheck(1)
All times are GMT -4. The time now is 12:45 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.