Sponsored Content
Top Forums Shell Programming and Scripting get physical and virtual memory Post 79781 by tads98 on Sunday 31st of July 2005 10:25:23 PM
Old 07-31-2005
Sorry, we are running an Oracle Database in a UNIX Server. Thanks for the help.
 

10 More Discussions You Might Find Interesting

1. AIX

ulimits max locked memory virtual memory

Hi, Would any one be so kind to explain me : are ulimits defined for each user seperately ? When ? Specialy what is the impact of : max locked memory and virtual memory on performance of applications for a user. Many thanks. PS : this is what I can see in MAN : ulimit ] ... (5 Replies)
Discussion started by: big123456
5 Replies

2. Solaris

How to find Total and Free Physical Memory and Logical Memory in SOLARIS 9

Hi, Im working on Solaris 9 on SPARC-32 bit running on an Ultra-80, and I have to find out the following:- 1. Total Physical Memory in the system(total RAM). 2. Available Physical Memory(i.e. RAM Usage) 3. Total (Logical) Memory in the system 4. Available (Logical) Memory. I know... (4 Replies)
Discussion started by: 0ktalmagik
4 Replies

3. Solaris

restrcit physical memory with zone.max-locked-memory

Is it possible to restrict physical memory in solaris zone with zone.max-locked-memory just like we can do with rcapd ? I do not want to used rcapd (1 Reply)
Discussion started by: fugitive
1 Replies

4. UNIX for Dummies Questions & Answers

translating physical/virtual addresses

Hi all, I am new to Linux kernel/user space programming having been an assembly programmer in my previous life. I am now using 2.6.x kernel on an embedded CPU that has a few dedicated hardware blocks (including more CPU running just C-code, i.e., no operating system). There is a single DRAM... (1 Reply)
Discussion started by: agaurav
1 Replies

5. Solaris

Physical or Virtual

Hi, I am on an Solaris machine "SunOS 5.10 Generic_139556-08 i86pc i386 i86pc"..how do i check if I am on an physical or an virtaul server. Thanks. (6 Replies)
Discussion started by: jjoy
6 Replies

6. Solaris

Solaris - physical to virtual migration on the same M5000

Hello, Firstly, apologies if the theme of this post is discussed elsewhere. At the moment we have a dual-domain M5000 running. Each domain is running with equal amounts of CPU and memory. What we'd like to do is move the 2 hosts in question (1 per domain) to a Solaris 10 zone of it's zone.... (2 Replies)
Discussion started by: nm146332
2 Replies

7. UNIX for Advanced & Expert Users

Server is virtual or physical?

Hi All, How can I know whether the server I am connecting to is a virtual or physical one? The server might be having any Unix OS (Linux/Solaris/HP-UX etc.). Is there any system files / commands which can show these concrete information? Thanks in advance for the replies. sanzee (1 Reply)
Discussion started by: sanzee007
1 Replies

8. Red Hat

Number of physical and virtual processors

Hi, i am trying to find out hpw many virtual and physical processors does any linux machine has: output of /proc/cpuinfo is as below : # cat /proc/cpuinfo processor : 0 vendor_id : GenuineIntel cpu family : 6 model : 26 model name : Intel(R) Xeon(R) CPU... (8 Replies)
Discussion started by: omkar.jadhav
8 Replies

9. AIX

Need help on physical and virtual cpu

HI, I need a command to find, 1) Avaiable Physical CPU 2) Avaiable virtual CPU TIA (1 Reply)
Discussion started by: sumanthupar
1 Replies

10. Solaris

Solaris 10 virtual - how do I tell physical host?

uname -a reports type Generic so I know its virtual. Assume its an ldom somewhere. How do I find out what physical host server is? (4 Replies)
Discussion started by: psychocandy
4 Replies
KSEG_TO_PHYS(9r)														  KSEG_TO_PHYS(9r)

NAME
KSEG_TO_PHYS - General: Converts a kernel-unmapped virtual address to a physical address SYNOPSIS
vm_offset_t KSEG_TO_PHYS( vm_offset_t addr ); ARGUMENTS
Specifies the buffer virtual address to convert to a physical address. DESCRIPTION
The KSEG_TO_PHYS routine converts a kernel-unmapped virtual address to a kernel physical address. Device drivers can use this physical address in DMA operations. Prior to calling KSEG_TO_PHYS, device driver writers often call one of the following routines to determine whether the address passed is a virtual address in the addressed kernel segment: IS_KSEG_VA Determines if the specified address is located in the kernel-unmapped address space. IS_SEG0_VA Determines if the specified address is located in the user-mapped address space. IS_SEG1_VA Determines if the specified address is located in the kernel-mapped address space. RETURN VALUES
Upon successful completion, KSEG_TO_PHYS returns the physical address. EXAMPLE
The following code fragment shows a call to KSEG_TO_PHYS: . . . caddr_t virt_addr; [1] unsigned phys_addr; [2] . . . if(IS_KSEG_VA(virt_addr)) { [3] phys_addr = KSEG_TO_PHYS(virt_addr); [4] . . . Declares a variable to store the user buffer's virtual address. Declares a variable to store the physical address returned by KSEG_TO_PHYS. Before calling KSEG_TO_PHYS, calls IS_KSEG_VA to determine if the virtual address is from the kernel-unmapped address space. If the virtual address is from the kernel-unmapped address space, then calls KSEG_TO_PHYS to convert the address to a corresponding physi- cal address. SEE ALSO
Routines: IS_KSEG_VA(9r), PHYS_TO_KSEG(9r) KSEG_TO_PHYS(9r)
All times are GMT -4. The time now is 07:25 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy