Special Forums Hardware Filesystems, Disks and Memory how can I monitoring the LUNs in HP storage Post 77590 by jgutierrez29 on Monday 11th of July 2005 10:19:23 AM
Old 07-11-2005
I´m looking a OSs devices monitoring vgs and lvols and raw devices
Jesus
 

2 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Storage Monitoring/Reporting?

Hi. How do you guys, monitor/report your Storage environment? I have people (don't we all? ) that like to have monthly reports on space (raw/assigned/available), ports available/used, switches and the such. Do you use anything special? Or are you like me, a nice big Excel spreadsheet? How... (1 Reply)
Discussion started by: Stephan
1 Replies

2. AIX

Migrating LUNs to new storage array

All, I have a AIX server with multiple volumes and I need to move them from a legacy storage SAN to a new SAN. We are concerned because to use mirrorvg as we would have to run on a single HBA (one on the old SAN and one on the new). Our other option is to use an appliance to do a block... (3 Replies)
Discussion started by: bkchicago
3 Replies
fence_scsi(8)						      System Manager's Manual						     fence_scsi(8)

NAME
fence_scsi - I/O fencing agent for SCSI persistent reservations SYNOPSIS
fence_scsi [OPTION]... DESCRIPTION
fence_scsi is an I/O fencing agent that uses SCSI-3 persistent reservations to control access to shared storage devices. These devices must support SCSI-3 persistent reservations (SPC-3 or greater) as well as the "preempt-and-abort" subcommand. The fence_scsi agent works by having each node in the cluster register a unique key with the SCSI devive(s). Once registered, a single node will become the reservation holder by creating a "write exclusive, registrants only" reservation on the device(s). The result is that only registered nodes may write to the device(s). When a node failure occurs, the fence_scsi agent will remove the key belonging to the failed node from the device(s). The failed node will no longer be able to write to the device(s). A manual reboot is required. In the cluster environment unfence action should be configured also. Keys are either be specified manually (see -k option) or generated automatically (see -n option). Automatic key generation requires that cman be running. Keys will then be generated using the cluster ID and node ID such that each node has a unique key that can be determined by any other node in the cluster. Devices can either be specified manually (see -d option) or discovered automatically. Multiple devices can be specified manually by using a comma-separated list. If no devices are specified, the fence_scsi agent will attempt to discover devices by looking for cluster volumes and extracting the underlying devices. Devices may be device-mapper multipath devices or raw devices. If using a device-mapper multipath device, the fence_scsi agent will find the underlying devices (paths) and created registrations for each path. OPTIONS
-o action Fencing action. This value can be "on", "off", "status", or "metadata". The "on", "off", and "status" actions require either a key (see -k option) or node name (see -n option). For "on", the agent will attempt to register with the device(s) and create a reserva- tion if none exists. The "off" action will attempt to remove a node's key from the device(s). The "status" action will report whether or not a node's key is currently register with one or more of the devices. The "metadata" action will display the XML meta- data. The default action if "off". -d devices List of devices to use for current operation. Devices can be comma-separated list of raw device (eg. /dev/sdc) or device-mapper mul- tipath devices (eg. /dev/dm-3). Each device must support SCSI-3 persistent reservations. -f logfile Log output to file. -n nodename Name of the node to be fenced. The node name is used to generate the key value used for the current operation. This option will be ignored when used with the -k option. -k key Key to use for the current operation. This key should be unique to a node. For the "on" action, the key specifies the key use to register the local node. For the "off" action, this key specifies the key to be removed from the device(s). -H delay Wait X seconds before fencing is started (Default Value: 0) -a Use the APTPL flag for registrations. This option is only used for the "on" action. -h Print out a help message describing available options, then exit. -v Verbose output. -V Print out a version message, then exit. STDIN PARAMETERS
agent = "param" This option is used by fence_node(8) and is ignored by fence_scsi. nodename = "param" Same as -n option. action = "param" Same as -o option. devices = "param" Same as -d option. logfile = "param" Same as -f option key = "param" Same as -k option. delay = "param" Same as -H option. aptpl = "1" Enable the APTPL flag. Default is 0 (disable). SEE ALSO
fence(8), fence_node(8), sg_persist(8), vgs(8), cman_tool(8), cman(5) fence_scsi(8)