that's a small missunderstanding between the win-word format and the solaris-word format. windows say to the creation of a filesystem formating in unix it is called like what it does: make a new filesystem Smilie
take a look at:
man newfs

greetings PRESSY
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Sun Ultra sparc 60

Hello everybody!! I need your help again. I am using Sun Ultra sparc 60 machine.Follwing are the types of files getting generated in /var/tmp. "windu_sm_o aaaa,baaa,caaa,daaa" etc. I am not able to locate which application is generating these files. Can I straightway delete these files ? or... (1 Reply)
Discussion started by: vikasdeshmukh
1 Replies

2. Solaris

sun ultra or sun sparkstation

am wonder wich sun computer is better, a sun ultra or sun sparkstation, and what is the difference (7 Replies)
Discussion started by: nobody
7 Replies

3. Solaris

sun ultra

Hi Guys, I have a 2nd hand Sun ultra-5, I wanted to know how to be able to run it as a normal window. I do not have any experience whatsoever with solaris/unix. Does anyone can give me a clue where to start. When I switch it goes to: unix console login: pa$$word: #UNIX sendmail : enable to... (0 Replies)
Discussion started by: lingosa
0 Replies

4. Solaris

hey i just got a Sun ultra 5!!!

now what do i do? im looking at it and i booted it after a bunch of code i got a line askign for the password i also downloaded solaris 10 any advice on how to install it? (36 Replies)
Discussion started by: russian460
36 Replies

5. Solaris

sun ultra 10 workstation

Hi All, I bought a sun workstation from ebay. Can I replace the cd-rom drive with a dvd-rom drive with any type? I mean, can I just buy a dvd-rom drive from a pc store? Thanks, itik (2 Replies)
Discussion started by: itik
2 Replies

6. Solaris

Sun Sparc Ultra 4 won't boot - disk errors

Hi all. I am seeing in one of our less-used servers that it crashed and now won't restart. I get the message 'continue with normal startup or boot into maintenance mode'. I go into maintenance and run fsck on /usr0 (mentioned in error at restart) it then reboots but goes right back to... (3 Replies)
Discussion started by: jamie_collins
3 Replies

7. Solaris

Sun Ultra 2 Hard Drive Replacement

Hi all...I have an old Sun Ultra 2 running SunOS 5.7 (I know old). These machines have 2 hard drives and one of my drives fried. I bought some replacement drives and wanted to a simple "dd" command from my one good drive to copy all to the new replacement drive. The new drives however give me a... (11 Replies)
Discussion started by: psantinello
11 Replies

8. Hardware

Sun Sparc Ultra 30 help

Hi all, I managed to salvage form work an old Sun Sparc Ultra 30. I have had it stored (controlled storage) for a few years and decided to get it home and boot it up. It starts up with a beep then I can hear disks spinning up, CDROM moving but nothing is displayed on the monitor. Can... (2 Replies)
Discussion started by: robbo007
2 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
metareplace(1M)                                           System Administration Commands                                           metareplace(1M)

NAME
metareplace - enable or replace components of submirrors or RAID5 metadevices SYNOPSIS
/usr/sbin/metareplace -h /usr/sbin/metareplace [-s setname] -e mirror component /usr/sbin/metareplace [-s setname] mirror component-old component-new /usr/sbin/metareplace [-s setname] -e RAID component /usr/sbin/metareplace [-s setname] [-f] RAID component-old component-new DESCRIPTION
The metareplace command is used to enable or replace components (slices) within a submirror or a RAID5 metadevice. When you replace a component, the metareplace command automatically starts resyncing the new component with the rest of the metadevice. When the resync completes, the replaced component becomes readable and writable. If the failed component has been hot spare replaced, the hot spare is placed in the available state and made available for other hot spare replacements. Note that the new component must be large enough to replace the old component. A component may be in one of several states. The Last Erred and the Maintenance states require action. Always replace components in the Maintenance state first, followed by a resync and validation of data. After components requiring maintenance are fixed, validated, and resynced, components in the Last Erred state should be replaced. To avoid data loss, it is always best to back up all data before replacing Last Erred devices. OPTIONS
Root privileges are required for all of the following options except -h. -e Transitions the state of component to the available state and resyncs the failed component. If the failed component has been hot spare replaced, the hot spare is placed in the available state and made available for other hot spare replace- ments. This command is useful when a component fails due to human error (for example, accidentally turning off a disk), or because the component was physically replaced. In this case, the replacement component must be partitioned to match the disk being replaced before running the metareplace command. -f Forces the replacement of an errored component of a metadevice in which multiple components are in error. The component determined by the metastat display to be in the ``Maintenance'' state must be replaced first. This option may cause data to be fabricated since multiple components are in error. -h Display help message. -s setname Specifies the name of the diskset on which metareplace will work. Using the -s option will cause the command to perform its administrative function within the specified diskset. Without this option, the command will perform its function on local metadevices. mirror The metadevice name of the mirror. component The logical name for the physical slice (partition) on a disk drive, such as /dev/dsk/c0t0d0s2. component-old The physical slice that is being replaced. component-new The physical slice that is replacing component-old. RAID The metadevice name of the RAID5 device. EXAMPLES
Example 1: Recovering from Error Condition in RAID5 Metadevice This example shows how to recover when a single component in a RAID5 metadevice is errored. # metareplace d10 c3t0d0s2 c5t0d0s2 In this example, a RAID5 metadevice d10 has an errored component, c3t0d0s2, replaced by a new component, c5t0d0s2. Example 2: Use of -e After Physical Disk Replacement This example shows the use of the -e option after a physical disk in a submirror (a submirror of mirror d11, in this case) has been replaced. # metareplace -e d11 c1t4d0s2 Note: The replacement disk must be partitioned to match the disk it is replacing before running the metareplace command. EXIT STATUS
The following exit values are returned: 0 Successful completion. >0 An error occurred. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWmdu | +-----------------------------+-----------------------------+ SEE ALSO
mdmonitord(1M), metaclear(1M), metadb(1M), metadetach(1M), metahs(1M), metainit(1M), metaoffline(1M), metaonline(1M), metaparam(1M), metarecover(1M), metarename(1M), metaroot(1M), metaset(1M), metassist(1M), metastat(1M), metasync(1M), metattach(1M), md.tab(4), md.cf(4), mddb.cf(4), md.tab(4), attributes(5), md(7D) Solaris Volume Manager Administration Guide SunOS 5.10 8 Aug 2003 metareplace(1M)