that's a small missunderstanding between the win-word format and the solaris-word format. windows say to the creation of a filesystem formating in unix it is called like what it does: make a new filesystem Smilie
take a look at:
man newfs

greetings PRESSY
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Sun Ultra sparc 60

Hello everybody!! I need your help again. I am using Sun Ultra sparc 60 machine.Follwing are the types of files getting generated in /var/tmp. "windu_sm_o aaaa,baaa,caaa,daaa" etc. I am not able to locate which application is generating these files. Can I straightway delete these files ? or... (1 Reply)
Discussion started by: vikasdeshmukh
1 Replies

2. Solaris

sun ultra or sun sparkstation

am wonder wich sun computer is better, a sun ultra or sun sparkstation, and what is the difference (7 Replies)
Discussion started by: nobody
7 Replies

3. Solaris

sun ultra

Hi Guys, I have a 2nd hand Sun ultra-5, I wanted to know how to be able to run it as a normal window. I do not have any experience whatsoever with solaris/unix. Does anyone can give me a clue where to start. When I switch it goes to: unix console login: pa$$word: #UNIX sendmail : enable to... (0 Replies)
Discussion started by: lingosa
0 Replies

4. Solaris

hey i just got a Sun ultra 5!!!

now what do i do? im looking at it and i booted it after a bunch of code i got a line askign for the password i also downloaded solaris 10 any advice on how to install it? (36 Replies)
Discussion started by: russian460
36 Replies

5. Solaris

sun ultra 10 workstation

Hi All, I bought a sun workstation from ebay. Can I replace the cd-rom drive with a dvd-rom drive with any type? I mean, can I just buy a dvd-rom drive from a pc store? Thanks, itik (2 Replies)
Discussion started by: itik
2 Replies

6. Solaris

Sun Sparc Ultra 4 won't boot - disk errors

Hi all. I am seeing in one of our less-used servers that it crashed and now won't restart. I get the message 'continue with normal startup or boot into maintenance mode'. I go into maintenance and run fsck on /usr0 (mentioned in error at restart) it then reboots but goes right back to... (3 Replies)
Discussion started by: jamie_collins
3 Replies

7. Solaris

Sun Ultra 2 Hard Drive Replacement

Hi all...I have an old Sun Ultra 2 running SunOS 5.7 (I know old). These machines have 2 hard drives and one of my drives fried. I bought some replacement drives and wanted to a simple "dd" command from my one good drive to copy all to the new replacement drive. The new drives however give me a... (11 Replies)
Discussion started by: psantinello
11 Replies

8. Hardware

Sun Sparc Ultra 30 help

Hi all, I managed to salvage form work an old Sun Sparc Ultra 30. I have had it stored (controlled storage) for a few years and decided to get it home and boot it up. It starts up with a beep then I can hear disks spinning up, CDROM moving but nothing is displayed on the monitor. Can... (2 Replies)
Discussion started by: robbo007
2 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
scdpm(1M)						  System Administration Commands						 scdpm(1M)

NAME
scdpm - manage disk path monitoring daemon SYNOPSIS
scdpm [-a] {node | all} scdpm -f filename scdpm -m {[node | all][:/dev/did/rdsk/]dN | [:/dev/rdsk/]cNtXdY | all} scdpm -n {node | all} scdpm -p [-F] {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} scdpm -u {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scdpm command manages the disk path monitoring daemon in a cluster. You use this command to monitor and unmonitor disk paths. You can also use this command to display the status of disk paths or nodes. All of the accessible disk paths in the cluster or on a specific node are printed on the standard output. You must run this command on a cluster node that is online and in cluster mode. You can specify either a global disk name or a UNIX path name when you monitor a new disk path. Additionally, you can force the daemon to reread the entire disk configuration. You can use this command only in the global zone. OPTIONS
The following options are supported: -a Enables the automatic rebooting of a node when all monitored disk paths fail, provided that the following conditions are met: o All monitored disk paths on the node fail. o At least one of the disks is accessible from a different node in the cluster. You can use this option only in the global zone. Rebooting the node restarts all resource and device groups that are mastered on that node on another node. If all monitored disk paths on a node remain inaccessible after the node automatically reboots, the node does not automatically reboot again. However, if any monitored disk paths become available after the node reboots but then all monitored disk paths again fail, the node automatically reboots again. You need solaris.cluster.device.admin role-based access control (RBAC) authorization to use this option. See rbac(5). -F If you specify the -F option with the -p option, scdpm also prints the faulty disk paths in the cluster. The -p option prints the cur- rent status of a node or a specified disk path from all the nodes that are attached to the storage. -f filename Reads a list of disk paths to monitor or unmonitor in filename. You can use this option only in the global zone. The following example shows the contents of filename. u schost-1:/dev/did/rdsk/d5 m schost-2:all Each line in the file must specify whether to monitor or unmonitor the disk path, the node name, and the disk path name. You specify the m option for monitor and the u option for unmonitor. You must insert a space between the command and the node name. You must also insert a colon (:) between the node name and the disk path name. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -m Monitors the new disk path that is specified by node:diskpath. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -n Disables the automatic rebooting of a node when all monitored disk paths fail. You can use this option only in the global zone. If all monitored disk paths on the node fail, the node is not rebooted. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -p Prints the current status of a node or a specified disk path from all the nodes that are attached to the storage. You can use this option only in the global zone. If you also specify the -F option, scdpm prints the faulty disk paths in the cluster. Valid status values for a disk path are Ok, Fail, Unmonitored, or Unknown. The valid status value for a node is Reboot_on_disk_failure. See the description of the -a and the -n options for more information about the Reboot_on_disk_failure status. You need solaris.cluster.device.read RBAC authorization to use this option. See rbac(5). -u Unmonitors a disk path. The daemon on each node stops monitoring the specified path. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). EXAMPLES
Example 1 Monitoring All Disk Paths in the Cluster Infrastructure The following command forces the daemon to monitor all disk paths in the cluster infrastructure. # scdpm -m all Example 2 Monitoring a New Disk Path The following command monitors a new disk path.All nodes monitor /dev/did/dsk/d3 where this path is valid. # scdpm -m /dev/did/dsk/d3 Example 3 Monitoring New Disk Paths on a Single Node The following command monitors new paths on a single node. The daemon on the schost-2 node monitors paths to the /dev/did/dsk/d4 and /dev/did/dsk/d5 disks. # scdpm -m schost-2:d4 -m schost-2:d5 Example 4 Printing All Disk Paths and Their Status The following command prints all disk paths in the cluster and their status. # scdpm -p schost-1:reboot_on_disk_failure enabled schost-2:reboot_on_disk_failure disabled schost-1:/dev/did/dsk/d4 Ok schost-1:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d5 Unmonitored schost-2:/dev/did/dsk/d6 Ok Example 5 Printing All Failed Disk Paths The following command prints all of the failed disk paths on the schost-2 node. # scdpm -p -F all schost-2:/dev/did/dsk/d4 Fail Example 6 Printing the Status of All Disk Paths From a Single Node The following command prints the disk path and the status of all disks that are monitored on the schost-2 node. # scdpm -p schost-2:all schost-2:reboot_on_disk_failure disabled schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok EXIT STATUS
The following exit values are returned: 0 The command completed successfully. 1 The command failed completely. 2 The command failed partially. Note - The disk path is represented by a node name and a disk name. The node name must be the host name or all. The disk name must be the global disk name, a UNIX path name, or all. The disk name can be either the full global path name or the disk name: /dev/did/dsk/d3 or d3. The disk name can also be the full UNIX path name: /dev/rdsk/c0t0d0s0. Disk path status changes are logged with the syslogd LOG_INFO facility level. All failures are logged with the LOG_ERR facility level. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cldevice(1CL), clnode(1CL), attributes(5) Sun Cluster System Administration Guide for Solaris OS Sun Cluster 3.2 22 Jun 2006 scdpm(1M)
All times are GMT -4. The time now is 12:02 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy