Sponsored Content
Operating Systems HP-UX How to recover Hp-ux O/S Disk from Mirro Disk Post 67427 by Kelam_Magnus on Wednesday 23rd of March 2005 11:33:02 AM
Old 03-23-2005
EDIT HERE: I noticed you said replace and reboot... Mine instructions were for a hot swap for a mirrored vg00 disk.


If it is a vg00 root OS disk that is what HP suggests...

If it is outside of vg00 but still an OS related disk then I agree.

vgcfgrestore (disk)
vgsync vgXX
 

6 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

recover DIsk and make bootable

Hello all, I'm trying to recover from backup file to a new system with a new disk. I'm able to partition my new hard drive the same way as my old drive, but I'm unable to boot off of it. I have set the fdisk to toogle as a boot flag. But it does not seem to be working. Does anyone know how to... (4 Replies)
Discussion started by: larryase
4 Replies

2. Solaris

( VxVM ) How to add the removed disk back to previous disk group

Previously , i remove the disk by #vxdg -g testdg -k rmdisk testdg02 But i got error when i -k adddisk bash-2.03# vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online invalid c0t1d0s2 auto:none ... (1 Reply)
Discussion started by: waibabe
1 Replies

3. SCO

Recover data from failed Hard disk in SCO OpenServer 5.06

One hard disk fail to mount (/dev/data). I had run "fsck /dev/data" then some error occured "unrecoverable error reading SCSI Disk 1 dev 1/104". I need to recover data from disk. please help. (1 Reply)
Discussion started by: rakeshkumar9919
1 Replies

4. Linux

How to Calculate Disk Queue length and Disk Busy Time

Hi, Am doing an enhancements related to monitoring a Linux disk I/O statistics. The /proc/diskstats file is used to get the each disk I/O statistics. But, It returns the raw value. How to calculate the Disk Queue Length and Disk Busy time from the raw values. Guide me. (1 Reply)
Discussion started by: maruthu
1 Replies

5. Solaris

Recover failed system disk

I have an oldish Solaris 10 system (SunFire x4240), which due to a recent heating event in the server room, lost it's system disk. I have rsync backups of all the other (data) disks, but apparently I do not have a backup of /. :-( I can start the machine up in failsafe mode, but running fsck on... (4 Replies)
Discussion started by: jj5406
4 Replies

6. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies
volreattach(8)						      System Manager's Manual						    volreattach(8)

NAME
volreattach - Reattaches disk drives that have once again become accessible SYNOPSIS
/usr/sbin/volreattach [-rb] [accessname...] /usr/sbin/volreattach -c accessname OPTIONS
The volreattach utility has the following options: Calls the volrecover utility to attempt to recover stale plexes of any volumes on the failed disk. Performs the reattach operation in the background. Checks whether a reattach is possible. No operation is performed, but the name of the disk group and disk media name at which the disk can be reattached is displayed. DESCRIPTION
The volreattach utility attempts to reattach disks using the same disk group and media names they had before detachment. This operation may be necessary if a disk has a transient failure, or if some disk drivers are unloaded or unloadable when the Logical Storage Manager is started, causing disks to enter the failed state. If the problem is fixed, the volreattach command can be used to reattach the disks without plexes being flagged as stale, as long as the reattach happens before any volumes on the disk are started. The volreattach command is called from the voldiskadm menus as part of disk recovery. The volreattach utility tries to find a disk with a disk group and disk ID matching that of the disk(s) being reattached. If the matching disk is found, the reattach operation may still fail if the original cause (or some other cause) for the disk failure still exists. EXIT CODES
A zero exit status is returned if it is possible to perform a reattach. Otherwise, non-zero is returned. SEE ALSO
volintro(8), voldiskadm(8), volrecover(8) volreattach(8)