Sponsored Content
Full Discussion: Pci Id
Operating Systems Solaris Pci Id Post 58641 by kduffin on Saturday 27th of November 2004 08:55:38 AM
Old 11-27-2004
kuultak,

What do you mean by 'PCI ID'? Are you just wanting to know which PCI slot a card is in? /usr/platform/sun4u/sbin/prtdiag will show you the slot number. Please elaborate so I can help.

Cheers,

Keith
 

9 More Discussions You Might Find Interesting

1. BSD

WLAN PCI Cards

Hi! I just wanted to know what network cards are supported in FreeBSD. I have looked at the list of supported cards but I can't find any of them in the stores. Is the list not updated, I would really preciate info about where (in EU, Sweden) I can buy them. /Peter (2 Replies)
Discussion started by: Barfly.se
2 Replies

2. Solaris

rs232 pci-card

hello mates, do you know a manufactor for rs232 serial pci cards for the sparc architecture? it seems that there is no original product from sun for that purpose. strange, isn't it? problem is that i have a V250 with only one db9 rs232 serial port, and i need it for a modem connection, but i also... (1 Reply)
Discussion started by: pressy
1 Replies

3. UNIX for Dummies Questions & Answers

bad pci slot?

Hi, im having a problem installing my pci wireless card. Im using knoppix, but my problem is with the mobo i think. im using an older laptop, toshiba satellite 2540 and when i plug in the card i get lights on sometimes. this means its getting power right. so then to install the card into the... (0 Replies)
Discussion started by: jestra
0 Replies

4. Solaris

How to look for open pci slots

I'm looking for open PCI slots in our array of sun boxes. I need help on how to distinguish if there's an open slot or not using prtdiag and prtconf. Is there a better tool for this? TIA. Here's my prtdiag -v | grep pci: pci 66 PCI5 SUNW,qlc-pci1077,2312 (scsi-+ ... (9 Replies)
Discussion started by: revzalot
9 Replies

5. Linux

PCI Card recognized

I installed PCI Card HP SC44Ge - SAS1068E on my linux CentOS 5.4 is there a way to find out if the PCI is properly installed and recognized by linux. lspci is enough? just to add that PCI card is connected to a tape... also how can I find out driver and firmware version? thanks a... (1 Reply)
Discussion started by: karlochacon
1 Replies

6. Programming

help writing pci firmware

For a project that I'm working on I want to write a low level PCI driver, but I can't seem to find any free/cheap documentation on PCI firmware specifications. I came across the "pci firmware specification 3.0" manual but this costs USD $1000 :eek:. I am not developing a commercial product... (13 Replies)
Discussion started by: neur0n
13 Replies

7. Solaris

available PCI slots on v440

How do I find any available PCI slots on a v440? When I run prtconf, I get the following output? But I am not able to make out whether all the PCI slots are used. ================================= IO Devices ================================= Bus Freq Brd Type MHz Slot ... (1 Reply)
Discussion started by: jtamminen
1 Replies

8. Hardware

Lspci: PCI Devices?

hey everyone, just a general question. I did an lspci on my home computer, and it got me thinking... When I hear pci..I think of the physical slots on your motherboard. usually beige in color.. But the list returned to me is of atleast 20 items. None of which, (besides the graphics card) is... (3 Replies)
Discussion started by: Lost in Cyberia
3 Replies

9. Hardware

Could USB ever take over PCI

Internally speaking, for your motherboard bus. Would it be possible for a usb standard to be used in place of the PCI or PCIe bus that is now nearly standard on all PC's? If not, why wouldn't this work? (8 Replies)
Discussion started by: Lost in Cyberia
8 Replies
cfgadm_pci(1M)						  System Administration Commands					    cfgadm_pci(1M)

NAME
cfgadm_pci - PCI Hotplug hardware specific commands for cfgadm SYNOPSIS
/usr/sbin/cfgadm [-f ] [-y | -n ] [-v] [-o hardware_options] -c function ap_id [ap_id] /usr/sbin/cfgadm [-f ] [-y | -n ] [-v] [-o hardware_options] -x hardware_function ap_id [ap_id] /usr/sbin/cfgadm [-v] [-s listing_options] [-o hardware_options] [-l [ ap_id | ap_type]] /usr/sbin/cfgadm [-v] [-o harware_options] -t ap_id [ap_id] /usr/sbin/cfgadm [-v] [-o hardware_function] -h [ ap_id| ap_type] DESCRIPTION
The PCI hardware specific library /usr/lib/cfgadm/pci.so.1 provides the support for hot plugging pci adapter cards into pci hot pluggable slots in a system that is hot plug capable, through the cfgadm command. See cfgadm(1M). For PCI Hot Plug, each hot plug slot on a specific PCI bus is represented by an attachment point of that specific PCI bus. An attachment point consist of two parts: a receptacle and an occupant. The receptacle under PCI hot plug is usually referred to as the physical hot pluggable slot; and the occupant is usually referred to as the PCI adapter card that plugs into the slot. Attachment points are named through ap_ids. There are two types of ap_ids: logical and physical. The physical ap_id is based on the physi- cal pathname, that is, /devices/pci@1/hpc0_slot3, whereas the logical ap_id is a shorter, and more user-friendly name. For PCI hot plug- gable slots, the logical ap_id is usually the corresponding hot plug controller driver name plus the logical slot number, that is, pci0:hpc0slot1; pci nexus driver, with hot plug controller driver named hpc and slot number 1. The ap_type for Hot plug PCI is pci. Note that the ap_type is not the same as the information in the Type field. See the System Administration Guide: Basic Administration for a detailed description of the hot plug procedure. OPTIONS
The following options are supported: -c function The following functions are supported for PCI hot pluggable slots: configure Configure the PCI device in the slot to be used by Solaris. connect Connect the slot to PCI bus. disconnect Disconnect the slot from the PCI bus. insert Not supported. remove Not supported. unconfigure Logically remove the PCI device's resources from the system. -f Not supported. -h ap_id | ap_type Print out PCI hot plug specific help message. -l list List the values of PCI Hot Plug slots. -o hardware_options No hardware specific options are currently defined. -s listing_options Same as the generic cfgadm(1M). -t ap_id This command is only supported on platforms which support testing capability on the slot. -v Execute in verbose mode. When -v is used with -l option the cfgadm command outputs information about the attachment point. For PCI Hot Plug, the Information field will be the slot's system label. This string will be obtained from the slot-name property of the slot's bus node. The information in the Type field is printed with or without the -v option. The occupant Type field will describe the contents of the slot. There are 2 possible values: unknown The slot is empty. If a card is in the slot, the card is not configured or there is no driver for the device on the card. subclass/board The card in the slot is either a single-function or multi-function device. subclass is a string representing the subclass code of the device, for example, SCSI, ethernet, pci-isa, and so forth. If the card is a multi-functional device, MULT will get printed instead. board is a string representing the board type of the device. For example, hp is the string used for a PCI Hot Plug adapter, hs is used for a Hot Swap Board, nhs for a Non--Hot Swap cPCI Board, bhs for a Basic Hot Swap cPCI Board, and fhs for a Full Hot Swap cPCI Board. Most pci cards with more than one device are not multi-function devices, but are implemented as a pci bridges with arbitrary devices behind them. In those cases, the subclass displayed is that of the pci bridge. Most com- monly the bridges are pci-pci, a generic pci to pci bridge or stpci, a semi-transparent pci bridge. -x hardware_function Perform hardware specific function. These hardware specific functions should not normally change the state of a receptacle or occupant. The following hardware_functions are supported: enable_slot | disable_slot Change the state of the slot and preserve the state of slot across reboot. Preservation of state across reboot is only supported on select platforms. enable_slot enables the addition of hardware to this slot for hot plugging and at boot time. disable_slot disables the addition of hardware to this slot for hot plugging and at boot time. When a slot is disabled its condi- tion is shown as unusable. enable_autoconfig | disable_autoconfig Change the ability to autoconfigure the occupant of the slot. Only platforms that support auto configuration support this feature. enable_autoconfig enables the ability to autoconfigure the slot. diable_autoconfig disables the ability to autoconfigure the slot. led=[led_sub_arg],mode=[mode_sub_arg] Without sub-arguments, print a list of the current LED settings. With sub-arguments, set the mode of a specific LED for a slot. Specify led_sub_arg as fault, power, att, or active. Specify mode_sub_arg as on, off or blink. Changing the state of the LED does not change the state of the receptacle or occupant. Normally, the LEDs are controlled by the hot plug controller, no user intervention is necessary. Use this command for testing purposes. Caution: Changing the state of the LED can misrepresent the state of occupant or receptacle. The following command prints the values of LEDs: example# cfgadm -x led pci0:hpc0_slot1 Ap_Id Led pci0:hpc0_slot1 power=on,fault=off,active=off,attn=off The following command turns on the Fault LED: example# cfgadm -x led=fault,mode=on pci0:hpc0_slot1 The following command turns off the Power LED: example# cfgadm -x led=power,mode=off pci0:hpc0_slot0 The following command sets the active LED to blink to indicate the location of the slot: example# cfgadm -x led=active,mode=on pci0:hpc0_slot3 EXAMPLES
Example 1: Printing out the Value of Each Slot The following command prints out the values of each slot: example# cfgadm -l Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c1 scsi-bus connected unconfigured unknown c2 scsi-bus connected unconfigured unknown cpci_slot1 stpci/fhs connected configured ok cpci_slot2 unknown empty unconfigured unknown cpci_slot4 stpci/fhs connected configured ok cpci_slot5 stpci/fhs connected configured ok Example 2: Replacing a Card The following command lists all DR-capable attachment points: example# cfgadm Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c1 scsi-bus connected unconfigured unknown c2 scsi-bus connected unconfigured unknown cpci_slot1 stpci/fhs connected configured ok cpci_slot2 unknown empty unconfigured unknown cpci_slot4 stpci/fhs connected configured ok cpci_slot5 stpci/fhs connected configured ok The following command unconfigures and electrically disconnects the card: example# cfgadm -c disconnect cpci_slot4 The change can be verified by entering the following command: example# cfgadm cpci_slot4 Ap_Id Type Receptacle Occupant Condition cpci_slot4 unknown disconnected unconfigured unknown Now the card can be swapped. The following command electrically connects and configures the card: example# cfgadm -c configure cpci_slot4 The change can be verifed by entering the following command: example# cfgadm cpci_slot4 Ap_Id Type Receptacle Occupant Condition cpci_slot4 stpcipci/fhs connected configured ok FILES
/usr/lib/cfgadm/pci.so.1 Hardware specific library for PCI hot plugging. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWkvm.u | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm(1M), config_admin(3CFGADM), libcfgadm(3LIB), attributes(5) System Administration Guide: Basic Administration SunOS 5.10 27 Oct 2003 cfgadm_pci(1M)
All times are GMT -4. The time now is 04:34 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy