11-09-2004
Oops!! sorry about the e-mail.
I know about the raid tools at first install of Redhat AS 2.1 but after that if you want expand, reduce or change a volume how do you do that. I know of Veritas can do that and the install software Raid tool but are there any other tools that allow you to expand or change a software Raid after install?
xtmeisel
9 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
Hi all,
I m just trying using software RAID in RHEL 4, without problem , then i wanna simulate if disk 1 is fail (thereis an bootloader), i plug off my 1st disk. My problems is the second disk cannot boot? just stuck in grub, the computer is hang. Sorry for poor concept in RAID? I use a RAID 1.... (0 Replies)
Discussion started by: blesets
0 Replies
2. HP-UX
Hi!
A couple of months ago a disk failed in our JBOD cabinett and I have finally got a new disk to replace it with. It was a RAID 0 so we have to create and configure the whole thing again. First we thought of RAID 1+0 but it seems you can't do this with LVM. If you read my last thread, you can... (0 Replies)
Discussion started by: hoff
0 Replies
3. Linux
Hey,
I have worked with Linux for some time, but have not gotten into the specifics of hard drive tuning or software RAID. This is about to change. I have a Dell PowerEdge T105 at home and I am purchasing the following:
1GBx4 DDR2 ECC PC6400 RAM
Rosewill RSV-5 E-Sata 5 bay disk enclosure... (6 Replies)
Discussion started by: mark54g
6 Replies
4. Red Hat
hi friends,
I am having issues with adding a spare device to a failed array.
I have created RAID 1 with 3 partitions using mdadm command. Later I added a spare with
mdadm --add /dev/md0 /dev/sdb6
This works fine and when I check this with mdadm --detail command it just sits there as a spare... (7 Replies)
Discussion started by: saagar
7 Replies
5. Filesystems, Disks and Memory
Hello,
My company has inherited a Centos based machine that has 7 hard drives and a software based raid system. Supposedly one of the drives has failed. I need to replace the hardrive.
How can I about telling which hard drive needs replacing? I have looked in the logs and there clearly is a... (5 Replies)
Discussion started by: mojoman
5 Replies
6. UNIX for Dummies Questions & Answers
Hi
Can someone tell me what are the differences between software and hardware raid ?
thx for help. (2 Replies)
Discussion started by: presul
2 Replies
7. Red Hat
We have configured software based RAID5 with LVM on our RHEL5 servers. Please let us know if its good to configure software RAID on live environment servers. What can be the disadvantages of software RAID against hardware RAID (4 Replies)
Discussion started by: mitchnelson
4 Replies
8. Solaris
Server Model: T5120 with 146G x4 disks.
OS: Solaris 10 - installed on c1t0d0.
Plan to use software raid (veritas volume mgr) on c1t2d0 disk.
After format and label the disk, still not able to detect using vxdiskadm.
Question:
Should I remove the hardware raid on c1t2d0 first?
My... (4 Replies)
Discussion started by: KhawHL
4 Replies
9. Solaris
We have hardware RAID configured on our T6320 server and two LDOMs are running on this server. One of our disk got failed and replaced. After replacemnt the newly installed disk not detected by RAID controlled so Oracle suggested to upgrade the REM firmware. As this is the standalone production... (0 Replies)
Discussion started by: rock123
0 Replies
LEARN ABOUT SUSE
install-solaris
install-solaris(1M) install-solaris(1M)
NAME
install-solaris - install the Solaris operating system
SYNOPSIS
install-solaris
install-solaris invokes the Solaris Install program. Depending on graphical capability and available memory at the time of invocation,
install-solaris invokes either a text-based installer or a graphical installer.
The following minimum requirements for physical memory dictate which features are available during installation:
For SPARC machines:
128 MB
Minimum physical memory for all installation types
128 MB
Minimum physical memory required for windowing system
384 MB
Minimum physical memory required for graphical-based installation
For x86 machines:
256 MB
Minimum physical memory for all installation types
256 MB
Minimum physical memory required for windowing system
512 MB
Minimum physical memory required for graphical-based installation
In some cases, even if the minimum physical memory is present, available virtual memory after system startup can limit the number of fea-
tures available.
install-solaris exists only on the Solaris installation media (CD or DVD) and should be invoked only from there. Refer to the for more
details.
install-solaris allows installation of the operating system onto any standalone system. install-solaris loads the software available on the
installation media. Refer to the for disk space requirements.
Refer to the for more information on the various menus and selections.
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SUNWcdrom (Solaris instal- |
| |lation media) |
+-----------------------------+-----------------------------+
|Interface Stability |Evolving |
+-----------------------------+-----------------------------+
pkginfo(1), install(1M), pkgadd(1M), attributes(5)
It is advisable to exit install-solaris by means of the exit options in the install-solaris menus.
23 Sep 2005 install-solaris(1M)