Sponsored Content
Full Discussion: IP Netflow collector
Special Forums IP Networking IP Netflow collector Post 54439 by bubba112557 on Friday 13th of August 2004 03:24:30 PM
Old 08-13-2004
IP Netflow collector

Help,

Does anybody know of any freeware Netflow collector tools to monitor IP traffic from Cisco routers and switches which run on Solaris?

Thanks!
 

We Also Found This Discussion For You

1. Programming

Boehm garbage collector for C

is anybody out there experienced with the boehm gc? this is a very simple function: int fn1(){ int *p = (int *) GC_MALLOC(sizeof(int *)); return 0; }after leaving fn1() gc should free p. *** now another example: int* fn2(){ int* p= (int *) GC_MALLOC(sizeof(int... (1 Reply)
Discussion started by: dodona
1 Replies
flow-send(1)						      General Commands Manual						      flow-send(1)

NAME
flow-send -- Transmit flow data with the NetFlow protocol. SYNOPSIS
flow-send [-h] [-d debug_level] [-m privacy_mask] [-s] [-x xmit_delay] [-V pdu_version] localip/remoteip/port DESCRIPTION
The flow-send utility is used to transmit flows in NetFlow format to a collector specified by localip/remoteip/port. OPTIONS
-d debug_level Enable debugging. -h Display help. -s Enable spoofing of source IP address. -m privacy_mask Apply privacy_mask to the source and destination IP address of flows. For example a privacy_mask of 255.255.255.0 would convert flows with source/destination IP addresses 10.1.1.1 and 10.2.2.2 to 10.1.1.0 and 10.2.2.0 respectively. -V pdu_version Use pdu_version format when transmitting. 1 NetFlow version 1 (No sequence numbers, AS, or mask) 5 NetFlow version 5 6 NetFlow version 6 (5+ Encapsulation size) 7 NetFlow version 7 (Catalyst switches) 8.1 NetFlow AS Aggregation 8.2 NetFlow Proto Port Aggregation 8.3 NetFlow Source Prefix Aggregation 8.4 NetFlow Destination Prefix Aggregation 8.5 NetFlow Prefix Aggregation 8.6 NetFlow Destination (Catalyst switches) 8.7 NetFlow Source Destination (Catalyst switches) 8.8 NetFlow Full Flow (Catalyst switches) 8.9 NetFlow ToS AS Aggregation 8.10 NetFlow ToS Proto Port Aggregation 8.11 NetFlow ToS Source Prefix Aggregation 8.12 NetFlow ToS Destination Prefix Aggregation 8.13 NetFlow ToS Prefix Aggregation 8.14 NetFlow ToS Prefix Port Aggregation 1005 Flow-Tools tagged version 5 -x xmit_delay Configure a microsecond transmit delay between packets. This may be necessary in some configurations to prevent a transmit buf- fer overrun. EXAMPLES
Transmit all flows in the directory /flows/krc4 to the collector at 10.0.0.1 listening on port 9500. flow-cat /flows/krc4 | flow-send 0/10.0.0.1/9500 Generate a test pattern of version 7 flows and send them to a collector at 10.0.0.1 listening on port 9500. flow-gen -V7 | flow-send 0/10.0.0.1/9500 BUGS
It is not currently possible to convert between the aggregated formats (8.x) and the non aggregated formats (1,5,6,7). AUTHOR
Mark Fullmer maf@splintered.net SEE ALSO
flow-tools(1) flow-send(1)
All times are GMT -4. The time now is 03:20 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy