07-07-2004
just wanted to know whether this db9 to db25 cross cable is also called as null modem cable?
Regards,
Raja
8 More Discussions You Might Find Interesting
1. UNIX Benchmarks
==============================================================
BYTE UNIX Benchmarks (Version 3.11)
System -- SunOS xxxxx 5.8 Generic_108528-13 sun4u sparc SUNW,Ultra-250
Start Benchmark Run: Sun Jan 11 19:47:12 EST 2004
1 interactive users.
Dhrystone 2 without register variables ... (0 Replies)
Discussion started by: kduffin
0 Replies
2. Solaris
it there any docs out there anyhwre that have the specs for cabing to a sun console.
I have an e420 here, i cant seem to get a console connection, i have triewd the silver serial connectors that come with the new dsun servers, but no luck with those. (1 Reply)
Discussion started by: BG_JrAdmin
1 Replies
3. Gentoo
We are retiring a Sun e250 at work, and I wondered if I could put it to any good use. Will I have any problems loading Linux as opposed to Solaris? Should I use any particular flavor of Linux that might be more Sun friendly? Assuming I manage to load Linux on this server, then what? Will it be... (9 Replies)
Discussion started by: kccrusher
9 Replies
4. Solaris
Hi,
I need some help, since I am new to cluster.
I am handling a site where I have look after two SUN E250 server.
I have been asked to configure Active-Active Clustering on these servers.
I would like to know how to configure both the servers for clustering.
Below are the things which... (5 Replies)
Discussion started by: RajaRC
5 Replies
5. Solaris
Hello,
Running a Sun Solaris 9 E250 and need advice or suggestions on what type of external hard disks are compatible and or available. It's an old machine and is due for replacement soon but in the short term need an external hard drive for backup etc as the partner/backup machine has just... (2 Replies)
Discussion started by: KenLynch
2 Replies
6. Solaris
Hi :
I have a e450 sun server that I just started up and I connect my laptop to the serial connection using a null modem cable and it just does not connect.
I use hyperterminal, I dont connect a keyboard to the sun machine?
Any ideas?
Thanks a lot
Al (3 Replies)
Discussion started by: alanj4
3 Replies
7. Solaris
Hi,
I have Solaris 10 8/07 on SPARC and I can't log in Web console. When I opened browser (Firefox 3) at localhost:6789 I get Save file dialog which asks me to save some file with .part at the end. What information should I provide to find out where is the trouble?..
Internet explorer says... (3 Replies)
Discussion started by: Sapfeer
3 Replies
8. Solaris
Hi everybody, my name is Giulia and for me is the fist time in this forum, i hope write in the correct section for my problem.
I have a sun solaris server e250 enterprise with sun 5 versionof O.S.
Now i wont format all and install new version of solaris, but i don't know the actual corrent... (7 Replies)
Discussion started by: giulia79
7 Replies
LEARN ABOUT SUSE
ocf_pacemaker_ping
OCF_PACEMAKER_PING(7) Pacemaker Configuration OCF_PACEMAKER_PING(7)
NAME
ocf_pacemaker_ping - node connectivity
SYNOPSIS
[OCF_RESKEY_pidfile=string] [OCF_RESKEY_dampen=integer] [OCF_RESKEY_name=string] [OCF_RESKEY_multiplier=integer]
[OCF_RESKEY_host_list=string] [OCF_RESKEY_attempts=integer] [OCF_RESKEY_timeout=integer] [OCF_RESKEY_options=string]
[OCF_RESKEY_debug=string]
ping [start | stop | reload | monitor | meta-data | validate-all]
DESCRIPTION
Every time the monitor action is run, this resource agent records (in the CIB) the current number of ping nodes the host can connect to. It
is essentially the same as pingd except that it uses the system ping tool to obtain the results.
SUPPORTED PARAMETERS
OCF_RESKEY_pidfile = string [/var/run//ping-default]
PID file
OCF_RESKEY_dampen = integer [5s]
Dampening interval
The time to wait (dampening) further changes occur
OCF_RESKEY_name = string [pingd]
Attribute name
The name of the attributes to set. This is the name to be used in the constraints.
OCF_RESKEY_multiplier = integer []
Value multiplier
The number by which to multiply the number of connected ping nodes by
OCF_RESKEY_host_list = string []
Host list
The list of ping nodes to count. Defaults to all configured ping nodes. Rarely needs to be specified.
OCF_RESKEY_attempts = integer [2]
no. of ping attempts
Number of ping attempts, per host, before declaring it dead
OCF_RESKEY_timeout = integer [2]
ping timeout in seconds
How long, in seconds, to wait before declaring a ping lost
OCF_RESKEY_options = string []
Extra Options
A catch all for any other options that need to be passed to ping.
OCF_RESKEY_debug = string [false]
Verbose logging
Enables to use default attrd_updater verbose logging on every call.
AUTHOR
Andrew Beekhof <andrew@beekhof.net>
Author.
Pacemaker Configuration 07/05/2010 OCF_PACEMAKER_PING(7)