Question Endian Conversion

Hi everybody,

I met this week a problem.

For now, we used TRU64 system based on alpha. Now, we're installing UP-UX systems (on Itanium). And we have problem with our files. Indeed, we use file with COMP-3, COMP-5 data. These files are used on both platforms. (we use also TXT files which describe the files we use)

I didn't found any tool to convert the file from a format to another one...

could you help me ? It is urgent.

I have to precise something...
HP-UX is a big Endian System
TRU-64 is a little Endian System...

Thanks

Smilie

Last edited by bigmike59270; 04-15-2004 at 03:04 AM..
 

7 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Endian issues in TCP/IP

Hello, Can anybody tell me whether the little endian-big endian issues will affect porting from True64 to HP UNIX or TCP/IP will take care of that? If it affects what can be the solution. Thank you, (3 Replies)
Discussion started by: informshilpa
3 Replies

2. UNIX for Advanced & Expert Users

AIX endian again

Hi all I know AIX is big-endian machine.But does it read bytes in normal way from LSB. Does it happen in some machine that at multi-byte integer level it is Little-endian and while reading a single byte it is Big-Endian. This is urgent Thanks in advance. (3 Replies)
Discussion started by: Shobhit
3 Replies

3. Programming

Big and Little Endian

We are developing an application using TLI for network communication.The Server Code is developed in Sun and client in SCO unix. When we route data from Client to Server we encrypt the data using DES algotithm utility.The problem we are facing that Sun uses Big Endian methodology to store data in... (1 Reply)
Discussion started by: S.P.Prasad
1 Replies

4. UNIX for Dummies Questions & Answers

Little Endiean and Big Endian

Dear Friends, I have one question in my mind. That question is "how to detect whether the system is little endiean or big endian" Processing the bit position is the difference between this endians. But I could not understand how to find the pariticular sytem works... (3 Replies)
Discussion started by: Nirmal Babu
3 Replies

5. UNIX and Linux Applications

Migrating Oracle from Big Endian to Little Endian Platorm

Hi, We are trying to migrate an oracle database from Sun Solaris (SunOS 5.9 Generic_118558-28 sun4u sparc SUNW,Ultra-60) to Linux 2.6.18-53.1.19.el5 #1 SMP Tue Apr 22 03:01:10 EDT 2008 x86_64 x86_64 x86_64 GNU/Linux which is basically a Big Endian to Little Endian conversion. We shutdown... (3 Replies)
Discussion started by: luft
3 Replies

6. Solaris

question about the little-endian in sparc

hi folks, in the sparc v9 manul , it says it is possible to access the memory data in little-endian mode, but there is only privilaged instruction that could set the PSTATE ( the cle bit ) regist. if I'm in the user mode , is it possible for me to access the data in little-endian mode? (10 Replies)
Discussion started by: zerocool_08
10 Replies

7. UNIX and Linux Applications

Endian vs pfsense??

Hi Endian firewall free version if we do compare pfsense For a LAN network with active user 1000 Which do you recommend Share (0 Replies)
Discussion started by: mnnn
0 Replies
atexit(3)						     Library Functions Manual							 atexit(3)

NAME
atexit - register a function to be called at program termination SYNOPSIS
DESCRIPTION
registers the function func to be called, without arguments, at normal program termination. Functions registered by are called in reverse order of registration. An call during exit processing is always unsuccessful. The number of registered functions should not exceed as specified in When necessary, or (see crt0(3) and dld.sl(5) for PA-RISC systems or dld.so(5) for Itanium-based systems) registers one or more functions with to allow some processing at normal program termination. This registration occurs before any other. RETURN VALUE
returns zero if the registration is successful; non-zero if unsuccessful. SEE ALSO
exit(2), crt0(3), dld.sl(5) for PA-RISC systems. dld.so(5) for Itanium-based systems. STANDARDS CONFORMANCE
atexit(3)
All times are GMT -4. The time now is 05:34 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy