Sponsored Content
Full Discussion: Duplex Settings
Operating Systems Solaris Duplex Settings Post 46121 by RTM on Thursday 8th of January 2004 01:08:08 PM
Old 01-08-2004
Found more info on sunsolve - note the following in that link:

The latest Solaris Ethernet devices and drivers (hme, qfe, eri, dmfe, ge, ce) are fully 802.3 compliant.
Even though these drivers have the ability to change auto-neg, speed and duplex settings,
Sun's preferred (and recommended) way is to auto-negotiate and not disable auto-neg capabilities!
In general, any commodity Level 2 Switch will work in a Solaris environment if it provides industry
standard features in the following areas of performance: Auto-Negotiation, Internal, Bandwidth, Buffering & Latency.

Note: Sun does not endorse nor recommend any particular makes or models of switches or hubs.
Always read the manufacturer's specifications to verify that a switch meets the requirements.

In some cases, auto-negotiation capabilities could be disabled on both sides of the link, e.g., for
troubleshooting, compatibility problems, or permanent link connections in order
to "lock" the speed and duplex of the Ethernet link.

Note: Both sides, the Solaris driver and switch (the "link partners"), must be set for the same capabilities.
Setting one side to auto-neg and forcing the other side will not work correctly.
 

10 More Discussions You Might Find Interesting

1. IP Networking

duplex

Hi all, What is the difference between half duplex and full duplex? What are the advantages and disadvantages of each mode, if any? Thanks. (3 Replies)
Discussion started by: sihong
3 Replies

2. UNIX for Dummies Questions & Answers

Full duplex at HUB?

Ok at the moment I have a hub whit 5 computers connected to it. It's a 10/100 NetGear hub. Ok I heard that there is some command I can run or a file I edit or something like that. But what the command/file/script/whatever does is tells you what connect speed it's connecting to the hub to. ... (4 Replies)
Discussion started by: merlin
4 Replies

3. UNIX for Dummies Questions & Answers

How to turn off duplex

I am using digital Unix and lpd. I have HP 4200n LaserJet TCP printer, but when I use lpr command, it always print duplex. I can turn off duplex feature at the panel of the printer, but then other Windows computer cannot print duplex. How can I set up /etc/printcap file so that it will be... (2 Replies)
Discussion started by: hiepng
2 Replies

4. Programming

full -duplex ?

what is meant by full duplex and half duplex? b'coz in differences b\w hub and switch ,i heard lot this duplex word so please help me (1 Reply)
Discussion started by: parvathy
1 Replies

5. HP-UX

command to change duplex settings..

Hi Folks, I want the command to change the duplex settings of a HP-UX server. Thanks in advance. Sagar. (2 Replies)
Discussion started by: sag71155
2 Replies

6. Solaris

Solaris 10 Speed and Duplex Settings: bge

Evening, I am attempting to change the speed and duplex settings on a single interface on a bge card on an m3000 SPARC server. Currently the settings are as follows: bge0 link: up speed: 1000 Mbps duplex: full bge1 link: up speed: 100 Mbps ... (13 Replies)
Discussion started by: brialt1
13 Replies

7. Solaris

How to find half duplex or full duplex

Hi, How to find whether the server is running with half duplex or full duplex. I tried with the following command ndd -get /dev/ but am not getting any output,. Is the command correct? Also let me know how to change from half to full duplex. (1 Reply)
Discussion started by: rogerben
1 Replies

8. AIX

How to change Speed Duplex

How to change Speed Duplex ! How to change Speed Duplex by command chdev -P -l ent1 -a media_speed=1000_Full_Duplex How to change Speed Duplex by Smitty . smitty chgenet -> select adapter -> change Media speed etc. -> set "Apply change to DATABASE only" to yes -> Enter -> ... (0 Replies)
Discussion started by: ITHelper
0 Replies

9. UNIX for Advanced & Expert Users

Help with duplex printing

I am able to use duplex printing with the -o duplex option. I am also printing landscape. It prints on the back of the page, however, I have to flip the page in order to see the other side right side up. Is there another option that will allow the duplex printing to print the right side up on front... (9 Replies)
Discussion started by: nickg
9 Replies

10. Shell Programming and Scripting

Need script help for monitoring duplex settings

So I have a server I am trying to set up a script to send a Wall message notifying of my eth0 nic being set to 100 half duplex instead of 100 full duplex. I know I am trying to read from /etc/sysconfig/network/ifcfg-eth0 to pull the parameters STARTMODE=onboot BOOTPROTO=static... (6 Replies)
Discussion started by: lutador72
6 Replies
dmfe(7D)							      Devices								  dmfe(7D)

NAME
dmfe - Davicom Fast Ethernet driver for Davicom DM9102A SYNOPSIS
/platform/sun4u/kernel/drv/sparcv9/dmfe DESCRIPTION
The dmfe Ethernet device provides 100Base-TX networking interfaces using the Davicom DM9102A chip, which incorporates its own internal transceiver. The dmfe driver is a multithreaded, loadable, clonable, GLD-based STREAMS driver. Multiple controllers installed within the system are supported by the driver. The dmfe driver functions include controller initialization, frame transmit and receive, promiscuous and multicast support, and error recovery and reporting. The 100Base-TX standard specifies an auto-negotiation protocol to automatically select the mode and speed of operation. The internal trans- ceiver is capable of performing autonegotiation with the remote-end of the link (link partner) and receives the capabilities of the remote end. It selects the highest common denominator mode of operation based on the priorities. The internal transceiver also supports a forced-mode of operation under which the driver selects the operational mode. APPLICATION PROGRAMMING INTERFACE
The /dev/dmfe cloning character-special device is used to access all Davicom DM9102A devices installed in the system. The dmfe driver is dependent on /kernel/misc/gld, a loadable kernel module that provides the dmfe driver with the DLPI and STREAMS func- tionality required of a LAN driver. See gld(7D) for more details on the primitives supported by the driver. You must send an explicit DL_ATTACH_REQ message to associate the opened stream with a particular device (ppa). The ppa ID is interpreted as an unsigned integer data type and indicates the corresponding device instance (unit) number. If the ppa field value does not correspond to a valid device instance number for this system, an error (DL_ERROR_ACK) is returned. The device is initialized on first attach and de-ini- tialized (stopped) at last detach. The values returned by the driver in the DL_INFO_ACK primitive in response to a DL_INFO_REQ are as follows: o Maximum SDU is 1500 (ETHERMTU - defined in sys/ethernet.h). o Minimum SDU is 0. o DLSAP address length is 8. o MAC type is DL_ETHER. o The sap length value is -2, meaning the physical address component is followed immediately by a 2-byte sap component within the DLSAP address. o The broadcast address value is the Ethernet/IEEE broadcast address (FF:FF:FF:FF:FF:FF). Once in the DL_ATTACHED state, you must send a DL_BIND_REQ to associate a particular Service Access Point (SAP) with the stream. CONFIGURATION
By default, the dmfe driver performs auto-negotiation to select the speed and mode of the link. Link speed and mode can be 100 Mbps (full or half-duplex) or 10 Mbps (full or half-duplex) as described in the 100Base-TX standard. The auto-negotiation protocol automatically selects speed mode (either 100 Mbps or 10 Mbps) and operation mode (either full-duplex or half- duplex) as the highest common denominator supported by both link partners. Because the dmfe device supports all modes, this effectively selects the highest-throughput mode supported by the other device. Alternatively, you can explicitly specify the link parameters by adding entries to the dmfe driver configuration file (/platform/sun4u/ker- nel/drv/dmfe.conf). You can set the speed parameter to 10 or 100 to force dmfe devices to operate at the specified speed. Additionally, you can set the full-duplex parameter to 0 or 1 to disable or force full-duplex operation, respectively. Note that specifying either "speed" or "full-duplex" explicitly disables auto-negotiation. To enable the driver to determine the appropri- ate setting for each parameter, you should always set both parameters. If it is necessary to force either speed or duplex setting (for example, because the dmfe device is connected to an ancient device or hub that does not support auto-negotiation), both parameters should be explicitly specified to match the requirements of the external device. FILES
/dev/dmfe Character special device /platform/sun4u/kernel/drv/dmfe.conf dmfe configuration file ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |x86 | +-----------------------------+-----------------------------+ SEE ALSO
attributes(5), gld(7D), dlpi(7P), streamio(7I) Writing Device Drivers STREAMS Programming Guide Network Interfaces Programmer's Guide SunOS 5.10 23 July 2003 dmfe(7D)
All times are GMT -4. The time now is 10:21 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy