How do I change the NIC from 100 full-duplex to autonegotiate?
 

4 More Discussions You Might Find Interesting

1. Solaris

application compiled on solaris 10 throwing error when executed on solaris 9

I have compiled my application on Solaris 10 with following description SunOS ldg1 5.10 Generic_138888-03 sun4v sparc SUNW,Sun-Blade-T6320 The compiler is Sun C++ 5.9 SunOS_sparc Patch 124863-01 2007/07/25 But when installing the application on Solaris 9 SunOS odcarch02 5.9... (2 Replies)
Discussion started by: ash_bit2k2
2 Replies

2. Solaris

Unable to login using ssh,telnet onto my solaris machine with solaris 10 installed

Hi, I am unable to login into my terminal hosting Solaris 10 and get the below error message "Server refused to allocate pty ld.so.1: sh: fatal: libc.so.1: open failed: No such file or directory " Is there anyways i can get into my machine and what kind of changes are required to be... (7 Replies)
Discussion started by: sankasu
7 Replies

3. Solaris

root disk mirroring in solaris volume manager for solaris 10

Need a procedure document to do "root disk mirroring in solaris volume manager for solaris 10". I hope some one will help me asap. I need to do it production environment. Let me know if you need any deatils on this. Thanks, Rama (1 Reply)
Discussion started by: ramareddi16
1 Replies

4. Solaris

Patching Procedure in Solaris 10 with sun cluster having Solaris zone

Hi Gurus I am not able to find the patching procedure for solaris 10 ( sol10 u11) to latest patchset with sun cluster having failover zones so that same I should follow. Take an instance, there are sol1 and sol2 nodes and having two failover zones like sozone1-rg and sozone2-rg and currently... (1 Reply)
Discussion started by: nick101
1 Replies
BGE(4)							   BSD Kernel Interfaces Manual 						    BGE(4)

NAME
bge -- Broadcom BCM57xx/BCM590x Gigabit/Fast Ethernet driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device miibus device bge Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): if_bge_load="YES" DESCRIPTION
The bge driver provides support for various NICs based on the Broadcom BCM570x, 571x, 572x, 575x, 576x, 578x, 5776x and 5778x Gigabit Ether- net controller chips and the 590x and 5779x Fast Ethernet controller chips. All of these NICs are capable of 10, 100 and 1000Mbps speeds over CAT5 copper cable, except for the SysKonnect SK-9D41 which supports only 1000Mbps over multimode fiber. The BCM570x builds upon the technology of the Alteon Tigon II. It has two R4000 CPU cores and is PCI v2.2 and PCI-X v1.0 compliant. It supports IP, TCP and UDP checksum offload for both receive and transmit, multiple RX and TX DMA rings for QoS applications, rules-based receive filtering, and VLAN tag stripping/insertion as well as a 256-bit multicast hash filter. Additional fea- tures may be provided via value-add firmware updates. The BCM570x supports TBI (ten bit interface) and GMII transceivers, which means it can be used with either copper or 1000baseX fiber applications. Note however the device only supports a single speed in TBI mode. Most BCM5700-based cards also use the Broadcom BCM5401 or BCM5411 10/100/1000 copper gigabit transceivers, which support autonegotiation of 10, 100 and 1000Mbps modes in full or half duplex. The BCM5700, BCM5701, BCM5702, BCM5703, BCM5704 and BCM5717 also support jumbo frames, which can be configured via the interface MTU setting. Selecting an MTU larger than 1500 bytes with the ifconfig(8) utility configures the adapter to receive and transmit jumbo frames. Using jumbo frames can greatly improve performance for certain tasks, such as file transfers and data streaming. The bge driver supports the following media types: autoselect Enable autoselection of the media type and options. The user can manually override the autoselected mode by adding media options to rc.conf(5). 10baseT/UTP Set 10Mbps operation. The ifconfig(8) mediaopt option can also be used to select either full-duplex or half-duplex modes. 100baseTX Set 100Mbps (Fast Ethernet) operation. The ifconfig(8) mediaopt option can also be used to select either full-duplex or half-duplex modes. 1000baseTX Set 1000baseTX operation over twisted pair. Only full-duplex mode is supported. 1000baseSX Set 1000Mbps (Gigabit Ethernet) operation. Both full-duplex and half-duplex modes are supported. The bge driver supports the following media options: full-duplex Force full duplex operation. half-duplex Force half duplex operation. For more information on configuring this device, see ifconfig(8). HARDWARE
The bge driver provides support for various NICs based on the Broadcom BCM570x family of Gigabit Ethernet controller chips, including the following: o 3Com 3c996-SX (1000baseSX) o 3Com 3c996-T (10/100/1000baseTX) o Dell PowerEdge 1750 integrated BCM5704C NIC (10/100/1000baseTX) o Dell PowerEdge 2550 integrated BCM5700 NIC (10/100/1000baseTX) o Dell PowerEdge 2650 integrated BCM5703 NIC (10/100/1000baseTX) o Dell PowerEdge R200 integrated BCM5750 NIC (10/100/1000baseTX) o Dell PowerEdge R300 integrated BCM5722 NIC (10/100/1000baseTX) o IBM x235 server integrated BCM5703x NIC (10/100/1000baseTX) o HP Compaq dc7600 integrated BCM5752 NIC (10/100/1000baseTX) o HP ProLiant NC7760 embedded Gigabit NIC (10/100/1000baseTX) o HP ProLiant NC7770 PCI-X Gigabit NIC (10/100/1000baseTX) o HP ProLiant NC7771 PCI-X Gigabit NIC (10/100/1000baseTX) o HP ProLiant NC7781 embedded PCI-X Gigabit NIC (10/100/1000baseTX) o Netgear GA302T (10/100/1000baseTX) o SysKonnect SK-9D21 (10/100/1000baseTX) o SysKonnect SK-9D41 (1000baseSX) LOADER TUNABLES
The following tunable can be set at the loader(8) prompt before booting the kernel, or stored in loader.conf(5). hw.bge.allow_asf Allow the ASF feature for cooperating with IPMI. Can cause system lockup problems on a small number of systems. Disabled by default. SYSCTL VARIABLES
The following variables are available as both sysctl(8) variables and loader(8) tunables: dev.bge.%d.forced_collapse Allow collapsing multiple transmit buffers into a single buffer to increase transmit performance with the cost of CPU cycles. The default value is 0 to disable transmit buffer collapsing. dev.bge.%d.forced_udpcsum Enable UDP transmit checksum offloading even if controller can generate UDP datagrams with checksum value 0. UDP datagrams with checksum value 0 can confuse receiver host as it means sender did not compute UDP checksum. The default value is 0 which disables UDP transmit checksum offloading. The interface need to be brought down and up again before a change takes effect. DIAGNOSTICS
bge%d: couldn't map memory A fatal initialization error has occurred. bge%d: couldn't map ports A fatal initialization error has occurred. bge%d: couldn't map interrupt A fatal initialization error has occurred. bge%d: no memory for softc struct! The driver failed to allocate memory for per-device instance information during initialization. bge%d: failed to enable memory mapping! The driver failed to initialize PCI shared memory mapping. This might happen if the card is not in a bus-master slot. bge%d: no memory for jumbo buffers! The driver failed to allocate memory for jumbo frames during initialization. bge%d: watchdog timeout The device has stopped responding to the network, or there is a problem with the network connection (cable). SEE ALSO
altq(4), arp(4), miibus(4), netintro(4), ng_ether(4), polling(4), vlan(4), ifconfig(8) HISTORY
The bge device driver first appeared in FreeBSD 4.5. AUTHORS