I am not able to figure out if the disk is in mirror or not (hardware RAID). c1t1d0s0 is the one, which I need to replace, as this one is in the failing state.
raidctl on that disk doesn't work, which I thought should work
Please suggest.
Thanks
---------UPDATE--------------
Didn't realized, I was supposed to use "/opt/StorMan/arcconf getconfig 1"
I am good now :-)
Last edited by solaris_1977; 04-22-2020 at 05:52 PM..
These 2 Users Gave Thanks to solaris_1977 For This Post:
I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Hi,
I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1"
The System did come preinstalled as it comes from sun. I did not do much on it.
I booted system using boot cdrom -s
gave format... (6 Replies)
Hi,
I have a question. Do LiveUpgrade supports hardware raid?
How to choose the configuration of the system disk for Solaris 10 SPARC?
1st Hardware RAID-1 and UFS
2nd Hardware RAID-1 and ZFS
3rd SVM - UFS and RAID1
4th Software RAID-1 and ZFS
I care about this in the future to take... (1 Reply)
hi all, will command metastats tell whether there is hardware layered raid ?
i intend to do patching and plug out one of the disks in case the one inside encountered issues. (1 Reply)
Server Model: T5120 with 146G x4 disks.
OS: Solaris 10 - installed on c1t0d0.
Plan to use software raid (veritas volume mgr) on c1t2d0 disk.
After format and label the disk, still not able to detect using vxdiskadm.
Question:
Should I remove the hardware raid on c1t2d0 first?
My... (4 Replies)
We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue.
We have 2 LDOM configured on this server and this server running on single disk.
#... (8 Replies)
Hi Guys,
One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine
But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Dear All ,
we have hardware raid 1 implemented on Solaris Disks.
We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers.
Thanks...
Rj (7 Replies)
Discussion started by: jegaraman
7 Replies
LEARN ABOUT HPUX
vxr5check
vxr5check(1M)vxr5check(1M)NAME
vxr5check - verify RAID-5 volume parity
SYNOPSIS
/etc/vx/bin/vxr5check [-i | -v] [-g diskgroup] volume
DESCRIPTION
The vxr5check utility compares the parity of each stripe of a RAID-5 volume specified by volume. vxr5check reads the data for each stripe,
generates the parity for this stripe, and compares this parity with the existing parity.
vxr5check can be run against the entire RAID-5 volume, or incrementally on RAID-5 stripe boundaries, by specifying the -i option.
OPTIONS -g diskgroup
Specifies the Veritas Volume Manager (VxVM) disk group name for the RAID-5 volume name for verification. If this option is not
specified, the default disk group is determined using the rules given in the vxdg(1M) manual page.
-i Verifies the RAID-5 volume incrementally per stripes. If a parity mismatch is found, that stripe location is displayed.
-v Verbose output for the incremental vxr5check verification. The verbose option outputs each stripe number that is being verified.
OUTPUT FORMAT
In verbose mode and incremental mode, summary reports for each stripe of the RAID-5 volume are printed in output records. If an error is
returned for a stripe, then an error message and stripe number are displayed. In non-verbose mode, if an error is returned, an error mes-
sage is displayed.
If a parity mismatch error is determined on a stripe, vxr5check exits on that stripe and does not continue for the remaining stripes in the
RAID-5 volume.
FILES
/usr/lib/vxvm/bin/vxr5vrfy The utility that vxr5check calls to perform RAID-5 parity verification operations for the specified RAID-5
volume.
EXIT CODES
The vxr5check utility exits with a non-zero status if the attempted operation fails. A non-zero exit code is not a complete indicator of
the problems encountered, but rather denotes the first condition that prevented further execution of the utility.
See vxintro(1M) for a list of standard exit codes.
NOTES
Do not run vxr5check on a volume that is in degraded mode.
SEE ALSO vxevac(1M), vxintro(1M), vxmend(1M), vxvol(1M)VxVM 5.0.31.1 24 Mar 2008 vxr5check(1M)