It doesn't work that way. First, you need to use a "command substitution" for the seq command. Then, $X will be expanded to 1 .. $#, NOT to the values of the respective positional parameters. There are other ways:
or
which will assign elements starting from 0, or, less favoured, using the deprecated (and dangerous) eval,
hi
i have a function
abc
{
//from this function i am passing args to antoher function like
def a b c j k l
}
now i want to count the no of args coming to def() function and iterate over those values
is there any way to do this one
please help (2 Replies)
Hi,
I am using SYBASE database. in my script i am connecting to DB via using isql.
isql -U${S_USER} -S${S_SERV} -D${S_DB} -P${S_PWD} -b0 -w3000 -h0 -s"|" -i${MYDIR}/ABC.sql -oXYZ.txt << FINSQL
i am taking a ABC.sql file to use the queries written in it and storing the output in... (3 Replies)
hi,
i have an rpm, and i am looking at the presinstall script. i can see it takes in an argument, but what i do not know is how this argument is passed to the script? is there something that calls the preinstall script? i thought the preinstall script was the first thing executed.
thanks (2 Replies)
Hi Guys,
I am trying to pass arguments to the script i am wrinting.
When no argument is passed or wrong argument is passed, the script needs to output the way it needs to be called and exit.
Currently, when no arguments is passed, it is not getting exited but goes on assuming those... (3 Replies)
Hi
I want to write a script which store all the parameters passed to the script into an array.
Once it is stored I want scan through the array and and delete those files for last month present inside the directory. The files in directory is appneded with YYYY_MM_DD.
I want to know how can I... (3 Replies)
this is my issue.
4 parameters are passed from korn shell to sql script.
parameter_1= varchar2 datatype or no value entered my user.
parameter_2= number datatype or no value entered my user.
parameter_3= number datatype or no value entered my user.
parameter_4= number datatype or no... (5 Replies)
Hi all,
I am trying to delete columns in a file using a script. The columns that need to be deleted are passed as arguments to the script.
The script should look like this
> delete_columns.sh <file_name.txt> <column_numbers_to_be_deleted>
The contents of the file_name.txt will be like ... (5 Replies)
My requirement is that I want to pass similar argument to a shell script and process it in the script. Something like below:
myScript.sh -c COMPONENT1 -c COMPONENT2 -a APPNote: -c option can be specified multiple times and -a is optional parameter
I know this can be achieved using... (2 Replies)
Hi All,
I have a script which intends to create as many variables at runtime, as the number of parameters passed to it. The script needs to save these parameter values in the variables created and print them
abc.sh
----------
export Numbr_Parms=$#
export a=1
while
do
export... (3 Replies)
Discussion started by: dev.devil.1983
3 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.