04-05-2020
Update (from one hour ago):
Updated the new community sites with latest posts, new users, likes, etc. from legacy site.
Ran an early preprocessing script against the legacy DB.
@Scrutinizer is testing a more refined version of preprocessing which will do even more migration magic. When he is ready, we will run his preprocessing script again the legacy DB and see how it looks.
Thanks for your patience.
We have already fixed the two bugs that we found in the initial launch; but are working to refine more custom bbcode issues.
6 More Discussions You Might Find Interesting
1. Shell Programming and Scripting
Hi All,
We will be doing a Solaris 8 to Solaris 10 migration migration, just wanted to know if there are any known / common issues arise from this migration from Shell script point of view.
I tried searching this site but mostly post are related to SA's question and jumpstart, etc. If there's... (4 Replies)
Discussion started by: arvindcgi
4 Replies
2. HP-UX
All,
We are migrating an application from HP-UX B.11.00 to HP-UX B.11.31 and both of them have the same informix version - 7.25se. However the compilers are different on both servers.
HP-UX B.11.00 - has B3913DB C.03.33 HP aC++ Compiler (S800)
HP-UX B.11.31 - has PHSS_40631 1.0 HP C/aC++... (2 Replies)
Discussion started by: helper
2 Replies
3. Programming
Dear Team
I am using DB2 v10 z/os database . Need expert guidance to figure out best way to track table activities ( Ex Delete, Insert,Update )
Scenario
We have a table which is critical and many developer/testing team access on daily basis . We had instance where some deleted... (1 Reply)
Discussion started by: Perlbaby
1 Replies
4. What is on Your Mind?
First a bit of history ....
A number of years ago one of our admins built a number of plugin systems for moderation, including (1) a voting system, (2) a "user feelings" system and (3) a confidential posting system. During this time, I was busy on other projects, not very active in the forums,... (1 Reply)
Discussion started by: Neo
1 Replies
5. What is on Your Mind?
OK.
Like we all do, we learn a lot from tests, test migrations, and so forth.
Today, I started from scratch on test migration 2, armed with a lot more knowledge,
The main differences are as follows:
Installed discourse plugin ruby-bbcode-to-md before starting the install
Modified... (30 Replies)
Discussion started by: Neo
30 Replies
6. What is on Your Mind?
Test Build 4 on New Server, with changes identified in discourse test builds 2 and 3, primarily:
Insuring ruby-bbcode-to-markdown is enabled.
Removing line breaks from ICODE to markdown in migration script.
Added vbpostid to posts in discourse to setup migrating vb "thanks" to discourse... (28 Replies)
Discussion started by: Neo
28 Replies
LEARN ABOUT HPUX
ifc_disable_mgmt_lun
ifc_disable_mgmt_lun(5) File Formats Manual ifc_disable_mgmt_lun(5)
NAME
ifc_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices
VALUES
Failsafe
Default
Allowed values
Enable discovery of management luns for array devices.
Disable discovery of management luns for array devices.
Recommended values
DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and
the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension
bus node. The entry for a legacy management lun looks like this:
On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual
extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns
requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of
management luns will free up virtual extension buses for use by data luns.
Who Is Expected to Change This Tunable?
System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device
special files.
Restrictions on Changing
Changes to this tunable take effect immediately. However, existing management luns will not be removed.
When Should the Tunable Be Turned On?
This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns.
What Are the Side Effects of Turning the Tunable Off?
None.
When Should the Tunable Be Turned Off?
When the functionality provided by the management luns is desired.
What Are the Side Effects of Turning the Tunable On?
Existing management luns in the legacy representation will show up in the state.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by HP.
SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M).
Tunable Kernel Parameters ifc_disable_mgmt_lun(5)