02-19-2020
Yes, using vscsi.
In the 'planning' phase of moving to npiv, but my infrastructure is a tad behind the times so to speak and my switches don't support vscsi.
When I had the chance to use npiv, due to time constraints I wasn't able to switch a box over to it. One of those projects where they needed it three weeks ago, so I just did it the quick and dirty way that I knew would work, and work well.
So if you are seeing it logged in, did you run cfgmgr after all the zoning?
6 More Discussions You Might Find Interesting
1. Solaris
Previously , i remove the disk by
#vxdg -g testdg -k rmdisk testdg02
But i got error when i -k adddisk
bash-2.03# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 auto:none - - online invalid
c0t1d0s2 auto:none ... (1 Reply)
Discussion started by: waibabe
1 Replies
2. Linux
Hi,
Am doing an enhancements related to monitoring a Linux disk I/O statistics.
The /proc/diskstats file is used to get the each disk I/O statistics. But, It returns the raw value.
How to calculate the Disk Queue Length and Disk Busy time from the raw values.
Guide me. (1 Reply)
Discussion started by: maruthu
1 Replies
3. Solaris
I have a solaris 10 system configured using NetApp as its storage, and the file systems are already configured as you can see from the example below:
root@moneta # df -h
Filesystem size used avail capacity Mounted on
/dev/md/dsk/d0 9.8G 513M 9.3G 6% /... (4 Replies)
Discussion started by: fretagi
4 Replies
4. AIX
hello folks,
I have a 300GB ROOTVG volume groups with one filesystem /backup having 200GB allocated space
Now, I cannot alt disk clone or mirrorvg this hdisk with another smaller disk. The disk size has to be 300GB; I tried alt disk clone and mirrorvg , it doesn't work. you cannot copy LVs as... (9 Replies)
Discussion started by: filosophizer
9 Replies
5. Filesystems, Disks and Memory
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Discussion started by: terrya
1 Replies
6. AIX
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (3 Replies)
Discussion started by: terrya
3 Replies
LEARN ABOUT HPUX
vxreattach
vxreattach(1M) vxreattach(1M)
NAME
vxreattach - reattach disk drives that have once again become accessible
SYNOPSIS
/etc/vx/bin/vxreattach [-br ] [accessname...]
/etc/vx/bin/vxreattach -c accessname
DESCRIPTION
The vxreattach utility reattaches disks to the disk group they were in and retains the same media name.
This operation may be necessary if a disk has a transient failure, or if Veritas Volume Manager (VxVM) starts with some disk drivers
unloaded and unloadable. Disks then enter the failed state. If the problem is fixed, vxreattach may be able to reattach the disks without
plexes being flagged as stale, as long as the reattach happens before any volumes on the disk are started.
vxreattach tries to find a disk in the same disk group with the same disk ID for the disk(s) to be reattached. The reattach operation may
fail even after finding the disk with the matching disk ID if the original cause (or some other cause) for the disk failure still exists.
vxreattach is usually invoked by vxdiskadm when performing disk recovery. It is not intended to be run directly by an administrator.
OPTIONS
-b Performs the reattach operation in the background.
-c Checks if a reattach is possible. No operation is performed, but the name of the disk group and disk media name at which the
disk can be reattached is displayed.
-r Tries to recover stale plexes of any volumes on the failed disk. It does this by calling vxrecover.
EXIT CODES
A zero exit status is returned if the reattach is performed; non-zero is returned otherwise.
See vxintro(1M) for a list of standard exit codes.
EXAMPLES
Check if reattachment of disk c1t2d0 is possible:
/etc/vx/bin/vxreattach -c c1t2d0
If reattachment is possible, vxreattach returns with an exit status of 0 and displays the disk group name and disk media name. If reat-
tachment is not possible, vxreattach returns an exit status of 2 and displays an error.
Attempt to reattach the disk in the foreground and try to recover stale plexes of any volumes on the disk:
/etc/vx/bin/vxreattach -r c1t2d0
If the reattachment is successful, vxreattach returns an exit status of 0. Otherwise, if an error occurs, vxreattach returns a non-zero
exit code as defined on vxintro(1M).
FILES
/etc/default/vxplex Standard defaults file that can be used to determine whether FastResync is used when attaching plexes. See vxplex(1M)
for details.
SEE ALSO
vxdiskadm(1M), vxintro(1M), vxplex(1M), vxrecover(1M)
VxVM 5.0.31.1 24 Mar 2008 vxreattach(1M)