Sponsored Content
Full Discussion: FC disk and ioinfo
Operating Systems AIX FC disk and ioinfo Post 303044287 by Phat on Tuesday 18th of February 2020 12:51:25 AM
Old 02-18-2020
no one has an idea on this Smilie
 

6 More Discussions You Might Find Interesting

1. Solaris

( VxVM ) How to add the removed disk back to previous disk group

Previously , i remove the disk by #vxdg -g testdg -k rmdisk testdg02 But i got error when i -k adddisk bash-2.03# vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online invalid c0t1d0s2 auto:none ... (1 Reply)
Discussion started by: waibabe
1 Replies

2. Linux

How to Calculate Disk Queue length and Disk Busy Time

Hi, Am doing an enhancements related to monitoring a Linux disk I/O statistics. The /proc/diskstats file is used to get the each disk I/O statistics. But, It returns the raw value. How to calculate the Disk Queue Length and Disk Busy time from the raw values. Guide me. (1 Reply)
Discussion started by: maruthu
1 Replies

3. Solaris

Convert from raw disk to solaris volume manager disk

I have a solaris 10 system configured using NetApp as its storage, and the file systems are already configured as you can see from the example below: root@moneta # df -h Filesystem size used avail capacity Mounted on /dev/md/dsk/d0 9.8G 513M 9.3G 6% /... (4 Replies)
Discussion started by: fretagi
4 Replies

4. AIX

Clone or mirror your AIX OS larger disk to smaller disk ?

hello folks, I have a 300GB ROOTVG volume groups with one filesystem /backup having 200GB allocated space Now, I cannot alt disk clone or mirrorvg this hdisk with another smaller disk. The disk size has to be 300GB; I tried alt disk clone and mirrorvg , it doesn't work. you cannot copy LVs as... (9 Replies)
Discussion started by: filosophizer
9 Replies

5. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

6. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)