1. Solaris

Sun Fire V440 and Patch 109147-39

Got an curious issue. I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on. The patch modified mainly the linker libraries and commands. ... (2 Replies)
Discussion started by: BOFH
2 Replies

2. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

3. Solaris

USB Hard Disk Drive Supported by Sun Fire V890

Hi, Can anyone suggest me any USB Hard Disk Drive which I can connect to Sun Fire V890 and take backup at a quick speed. A test with SolidState USB Hard Drive for backup work was taking writing at 2GB per hour for a 75GB backup. Regards, Tushar Kathe (1 Reply)
Discussion started by: tushar_kathe
1 Replies

4. Solaris

Sun Fire v440 hardware problem (can't get ok>)

First of all it's shut down 60 second after power on and write on console : SC Alert: Correct SCC not replaced - shutting managed system down! This is cured by moving out battery from ALOM card. Now server start to loop during the testing. That's on the console: >@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies

5. Solaris

error messages in Sun Fire V440

Hello, I am seeing error messages in V440 (OS = solaris 8). I have copied here : The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day.. I... (5 Replies)
Discussion started by: upengan78
5 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Firmware password Solaris Sun Fire v440

Hi: I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies

8. Solaris

Sun Fire v440 Over heat Problem.

Dear Team, I need some expert advice to my problem. We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies

10. Solaris

Removing a disk from SUN Fire V440 running Solaris 8

Hi, I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either. Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
raidctl(1M)						  System Administration Commands					       raidctl(1M)

NAME
raidctl - RAID hardware utility SYNOPSIS
raidctl -c disk1 disk2 raidctl -d disk1 raidctl [-f] -F filename controller... raidctl -l [controller...] DESCRIPTION
The raidctl utility creates, deletes, or displays RAID volumes of the LSI1030 HW Raid controllers that include RAID support. The utility also updates firmware/fcode/BIOS for both RAID and non-RAID controllers. The raidctl utility requires privileges that are controlled by the underlying file-system permissions. Only privileged users can manipulate the RAID system configuration. If a non-privileged user attempts to create or delete a RAID volume, the command fails with EPERM. Without options, raidctl displays the current RAID configuration on all exisiting controllers. OPTIONS
The following options are supported: -c disk1 disk2 (for on board) Create a mirror using disk1 and disk2. Replace the contents of disk2 with the contents of disk1. Specify disk1 and disk2 in canonical form, for example, c0t0d0. When you create a a RAID volume, the RAID volume assumes the identity of the first target in the disk pair (disk1). The second target (disk2) disappears from the system. Therefore, the RAID volume appears as one disk. To have a successful RAID creation, there must not already be a RAID configuration present on the specified controller. Additionally, the secondary disk must not be mounted, as it has all its data erased and replaced with the primary disk's data. -d disk1 (for on board) Delete the RAID volume specified as disk1. Specify disk1 in canonical form, for example, c0t0d0. -f (for HBA) Force an update. Do not prompt. -F filename controller (for HBA) Update the firmware running on the specified controller (controller). -l [controller ...] (for on board) List the system's RAID configuration. If controller is specified, list RAID configurations for controller. Output from the -l lists the following information: RAID Volume Displays logical RAID volume name. RAID Status Displays RAID status as either RESYNCING (disks are syncing), DEGRADED RAID is operating with reduced functionality), OK (operating optimally), or FAILED (non-functional). RAID Disk Displays RAID disk name. Disk Status Displays disk status as either OK or FAILED. EXAMPLES
Example 1: Creating the RAID Configuration The following command creates the RAID configuration: # raidctl -c c0t0d0 c0t1d0 RAID Volume 'c0t0d0' created Example 2: Displaying the RAID Configuration The following command displays the RAID configuration: # raidctl RAID RAID RAID Disk Volume Status Disk Status ---------------------------------------- c0t0d0 RESYNCING c0t0d0 OK c0t1d0 OK Example 3: Deleting the RAID Configuration The following command deletes the RAID configuration: # raidctl -d c0t0d0 RAID Volume 'c0t0d0' deleted Example 4: Updating Flash Images on the Controller The following command updates flash images on the controller: # raidctl -F lsi1030.fw 0 Update flash image on controller 0? (y/N): y Flash updated successfully EXIT STATUS
The following exit values are returned: 0 Successful completion. 1 Invalid command line input. 2 Request operation failed. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ SEE ALSO
attributes(5) System Administration Guide: Basic Administration SunOS 5.10 17 Aug 2004 raidctl(1M)
All times are GMT -4. The time now is 11:14 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy