Sponsored Content
Operating Systems Solaris Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1) Post 303044081 by hicksd8 on Thursday 13th of February 2020 12:52:07 PM
Old 02-13-2020
Use the switch:

Code:
-o b=32

on the command line to use superblock at block=32.
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun Fire V440 and Patch 109147-39

Got an curious issue. I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on. The patch modified mainly the linker libraries and commands. ... (2 Replies)
Discussion started by: BOFH
2 Replies

2. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

3. Solaris

USB Hard Disk Drive Supported by Sun Fire V890

Hi, Can anyone suggest me any USB Hard Disk Drive which I can connect to Sun Fire V890 and take backup at a quick speed. A test with SolidState USB Hard Drive for backup work was taking writing at 2GB per hour for a 75GB backup. Regards, Tushar Kathe (1 Reply)
Discussion started by: tushar_kathe
1 Replies

4. Solaris

Sun Fire v440 hardware problem (can't get ok>)

First of all it's shut down 60 second after power on and write on console : SC Alert: Correct SCC not replaced - shutting managed system down! This is cured by moving out battery from ALOM card. Now server start to loop during the testing. That's on the console: >@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies

5. Solaris

error messages in Sun Fire V440

Hello, I am seeing error messages in V440 (OS = solaris 8). I have copied here : The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day.. I... (5 Replies)
Discussion started by: upengan78
5 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Firmware password Solaris Sun Fire v440

Hi: I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies

8. Solaris

Sun Fire v440 Over heat Problem.

Dear Team, I need some expert advice to my problem. We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies

10. Solaris

Removing a disk from SUN Fire V440 running Solaris 8

Hi, I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either. Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
IRSEND(1)								FSF								 IRSEND(1)

NAME
irsend - basic LIRC program to send infra-red commands SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...] DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such as TV boxes, HiFi sets, etc. DIRECTIVE can be: SEND_ONCE - send CODE [CODE ...] once SEND_START - start repeating CODE SEND_STOP - stop repeating CODE LIST - list configured remote items SET_TRANSMITTERS - set transmitters NUM [NUM ...] SIMULATE - simulate IR event REMOTE is the name of a remote, as described in the lircd configuration file. CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file. NUM is the transmitter number of the hardware device. For the LIST DIRECTIVE, REMOTE and/or CODE can be empty: LIST "" "" - list all configured remote names LIST REMOTE "" - list all codes of REMOTE LIST REMOTE CODE - list only CODE of REMOTE The SIMULATE command only works if it has been explicitly enabled in lircd. -h --help display usage summary -v --version display version -d --device use given lircd socket [/var/run/lirc/lircd] -a --address=host[:port] connect to lircd at this address -# --count=n send command n times EXAMPLES
irsend LIST DenonTuner "" irsend SEND_ONCE DenonTuner PROG-SCAN irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3 irsend SEND_STOP OnkyoAmpli VOL-DOWN irsend SET_TRANSMITTERS 1 irsend SET_TRANSMITTERS 1 3 4 irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S" FILES
/etc/lirc/lircd.conf Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave- form details. DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics: "irsend: could not connect to socket" "irsend: Connection refused" (or "Permission denied"). SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory. lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org. irsend 0.8.7pre1 May 2010 IRSEND(1)
All times are GMT -4. The time now is 01:53 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy