Operating Systems Solaris Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1) Post 303044075 by hicksd8 on Thursday 13th of February 2020 11:25:04 AM
Old 02-13-2020
Probably a good idea just to do a root filesystem check with a "no write" flag. That way you get to see what damage there is without the risk that it will try to fix it. It will show you the difference as to whether there is one file corrupt or one million files corrupt.
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun Fire V440 and Patch 109147-39

Got an curious issue. I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on. The patch modified mainly the linker libraries and commands. ... (2 Replies)
Discussion started by: BOFH
2 Replies

2. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

3. Solaris

USB Hard Disk Drive Supported by Sun Fire V890

Hi, Can anyone suggest me any USB Hard Disk Drive which I can connect to Sun Fire V890 and take backup at a quick speed. A test with SolidState USB Hard Drive for backup work was taking writing at 2GB per hour for a 75GB backup. Regards, Tushar Kathe (1 Reply)
Discussion started by: tushar_kathe
1 Replies

4. Solaris

Sun Fire v440 hardware problem (can't get ok>)

First of all it's shut down 60 second after power on and write on console : SC Alert: Correct SCC not replaced - shutting managed system down! This is cured by moving out battery from ALOM card. Now server start to loop during the testing. That's on the console: >@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies

5. Solaris

error messages in Sun Fire V440

Hello, I am seeing error messages in V440 (OS = solaris 8). I have copied here : The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day.. I... (5 Replies)
Discussion started by: upengan78
5 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Firmware password Solaris Sun Fire v440

Hi: I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies

8. Solaris

Sun Fire v440 Over heat Problem.

Dear Team, I need some expert advice to my problem. We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies

10. Solaris

Removing a disk from SUN Fire V440 running Solaris 8

Hi, I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either. Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
FSCK.MINIX(8)						       System Administration						     FSCK.MINIX(8)

NAME
fsck.minix - check consistency of Minix filesystem SYNOPSIS
fsck.minix [options] device DESCRIPTION
fsck.minix performs a consistency check for the Linux MINIX filesystem. The program assumes the filesystem is quiescent. fsck.minix should not be used on a mounted device unless you can be sure nobody is writ- ing to it. Remember that the kernel can write to device when it searches for files. The device name will usually have the following form: /dev/hda[1-63] IDE disk 1 /dev/hdb[1-63] IDE disk 2 /dev/sda[1-15] SCSI disk 1 /dev/sdb[1-15] SCSI disk 2 If the filesystem was changed, i.e., repaired, then fsck.minix will print "FILE SYSTEM HAS CHANGED" and will sync(2) three times before exiting. There is no need to reboot after check. WARNING
fsck.minix should not be used on a mounted filesystem. Using fsck.minix on a mounted filesystem is very dangerous, due to the possibility that deleted files are still in use, and can seriously damage a perfectly good filesystem! If you absolutely have to run fsck.minix on a mounted filesystem, such as the root filesystem, make sure nothing is writing to the disk, and that no files are "zombies" waiting for deletion. OPTIONS
-l, --list List all filenames. -r, --repair Perform interactive repairs. -a, --auto Perform automatic repairs. This option implies --repair and serves to answer all of the questions asked with the default. Note that this can be extremely dangerous in the case of extensive filesystem damage. -v, --verbose Be verbose. -s, --super Output super-block information. -m, --uncleared Activate MINIX-like "mode not cleared" warnings. -f, --force Force a filesystem check even if the filesystem was marked as valid. Marking is done by the kernel when the filesystem is unmounted. -V, --version Display version information and exit. -h, --help Display help text and exit. DIAGNOSTICS
There are numerous diagnostic messages. The ones mentioned here are the most commonly seen in normal usage. If the device does not exist, fsck.minix will print "unable to read super block". If the device exists, but is not a MINIX filesystem, fsck.minix will print "bad magic number in super-block". EXIT CODES
The exit code returned by fsck.minix is the sum of the following: 0 No errors 3 Filesystem errors corrected, system should be rebooted if filesystem was mounted 4 Filesystem errors left uncorrected 7 Combination of exit codes 3 and 4 8 Operational error 16 Usage or syntax error AUTHORS
Linus Torvalds <torvalds@cs.helsinki.fi> Error code values by Rik Faith <faith@cs.unc.edu> Added support for filesystem valid flag: Dr. Wettstein <greg%wind.uucp@plains.nodak.edu>. Check to prevent fsck of mounted filesystem added by Daniel Quinlan <quinlan@yggdrasil.com>. Minix v2 fs support by Andreas Schwab <schwab@issan.informatik.uni-dortmund.de>, updated by Nicolai Langfeldt <janl@math.uio.no>. Portability patch by Russell King <rmk@ecs.soton.ac.uk>. SEE ALSO
fsck(8), fsck.ext2(8), mkfs(8), mkfs.ext2(8), mkfs.minix(8), reboot(8) AVAILABILITY
The fsck.minix command is part of the util-linux package and is available from Linux Kernel Archive <https://www.kernel.org/pub/linux/utils /util-linux/>. util-linux June 2015 FSCK.MINIX(8)
All times are GMT -4. The time now is 03:28 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy