02-13-2020
Do I need to issue a command in order to remove one of the disks? Is the raid hotplug capable?
10 More Discussions You Might Find Interesting
1. Solaris
Got an curious issue.
I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on.
The patch modified mainly the linker libraries and commands.
... (2 Replies)
Discussion started by: BOFH
2 Replies
2. Solaris
Hello,
I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies
3. Solaris
Hi,
Can anyone suggest me any USB Hard Disk Drive which I can connect to Sun Fire V890 and take backup at a quick speed. A test with SolidState USB Hard Drive for backup work was taking writing at 2GB per hour for a 75GB backup.
Regards,
Tushar Kathe (1 Reply)
Discussion started by: tushar_kathe
1 Replies
4. Solaris
First of all it's shut down 60 second after power on and write on console :
SC Alert: Correct SCC not replaced - shutting managed system down!
This is cured by moving out battery from ALOM card.
Now server start to loop during the testing.
That's on the console:
>@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies
5. Solaris
Hello,
I am seeing error messages in V440 (OS = solaris 8). I have copied here :
The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day..
I... (5 Replies)
Discussion started by: upengan78
5 Replies
6. AIX
Hello,
I have a scsi pci x raid controller card on which I had created a disk array of 3 disks
when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk )
suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies
7. Solaris
Hi:
I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies
8. Solaris
Dear Team,
I need some expert advice to my problem.
We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies
9. Solaris
Hi,
I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is
Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken.
Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies
10. Solaris
Hi,
I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either.
Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
LEARN ABOUT CENTOS
rescan-scsi-bus.sh
RESCAN-SCSI-BUS.SH(1) User Commands RESCAN-SCSI-BUS.SH(1)
NAME
rescan-scsi-bus.sh - script for adding and removing SCSI devices without rebooting
SYNOPSIS
rescan-scsi-bus.sh [options] [host [host ...]]
OPTIONS
-a, --alltargets
scan all targets, not just currently existing [default: disabled]
-d enable debug [default: 0]
-l activates scanning for LUNs 0--7 [default: 0]
-L NUM activates scanning for LUNs 0--NUM [default: 0]
-w, --wide
scan for target device IDs 0--15 [default: 0--7]
-c enables scanning of channels 0 1 [default: 0 / all detected ones]
-r, --remove
enables removing of devices [default: disabled]
-f, --flush
flush failed multipath devices [default: disabled]
-i, --issue-lip
issue a FibreChannel LIP reset [default: disabled]
-u, --update
look for existing disks that have been remapped
-s, --resize
look for resized disks and reload associated multipath devices, if applicable
--forcerescan
rescan existing devices
--forceremove
remove and readd every device (DANGEROUS)
--nooptscan
don't stop looking for LUNs is 0 is not found
--color
use coloured prefixes OLD/NEW/DEL
--hosts=LIST
scan only host(s) in LIST
--channels=LIST
scan only channel(s) in LIST
--ids=LIST
scan only target ID(s) in LIST
--luns=LIST
scan only lun(s) in LIST
--sync, --nosync
issue a sync / no sync [default: sync if remove]
--attachpq3
tell kernel to attach sg to LUN 0 that reports PQ=3
--reportlun2
tell kernel to try REPORT_LUN even on SCSI2 devices
--largelun
tell kernel to support LUNs > 7 even on SCSI2 devs
--sparselun
tell kernel to support sparse LUN numbering
Host numbers may thus be specified either directly on cmd line (deprecated) or or with the --hosts=LIST parameter (recommended).
LIST: A[-B][,C[-D]]... is a comma separated list of single values and ranges (No spaces allowed.)
SEE ALSO
rescan-scsi-bus.sh Homepage: http://www.garloff.de/kurt/linux/#rescan-scsi
sg3_utils Homepage: http://sg.danny.cz/sg
rescan-scsi-bus.sh 1.57 leden 2014 RESCAN-SCSI-BUS.SH(1)