Sponsored Content
Operating Systems Solaris Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1) Post 303044057 by oliwei on Thursday 13th of February 2020 05:25:14 AM
Old 02-13-2020
Hi,


the status is shown as optimal. I would guess that if a disk is failed or failing raidctl would show that? How can I identify which of the two disks are bad if raidctl claims everything is ok. I have powered down the server many times. I have not replugged all the cables yet. I will give it a try.

Last edited by hicksd8; 02-13-2020 at 06:32 AM..
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun Fire V440 and Patch 109147-39

Got an curious issue. I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on. The patch modified mainly the linker libraries and commands. ... (2 Replies)
Discussion started by: BOFH
2 Replies

2. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

3. Solaris

USB Hard Disk Drive Supported by Sun Fire V890

Hi, Can anyone suggest me any USB Hard Disk Drive which I can connect to Sun Fire V890 and take backup at a quick speed. A test with SolidState USB Hard Drive for backup work was taking writing at 2GB per hour for a 75GB backup. Regards, Tushar Kathe (1 Reply)
Discussion started by: tushar_kathe
1 Replies

4. Solaris

Sun Fire v440 hardware problem (can't get ok>)

First of all it's shut down 60 second after power on and write on console : SC Alert: Correct SCC not replaced - shutting managed system down! This is cured by moving out battery from ALOM card. Now server start to loop during the testing. That's on the console: >@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies

5. Solaris

error messages in Sun Fire V440

Hello, I am seeing error messages in V440 (OS = solaris 8). I have copied here : The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day.. I... (5 Replies)
Discussion started by: upengan78
5 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Firmware password Solaris Sun Fire v440

Hi: I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies

8. Solaris

Sun Fire v440 Over heat Problem.

Dear Team, I need some expert advice to my problem. We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies

10. Solaris

Removing a disk from SUN Fire V440 running Solaris 8

Hi, I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either. Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
badsect(8)						      System Manager's Manual							badsect(8)

NAME
badsect - Creates files to contain bad sectors SYNOPSIS
/usr/sbin/badsect bbdir sector... DESCRIPTION
The badsect command makes a file to contain a bad sector. Normally, bad sectors are made inaccessible by the standard formatter, which provides a forwarding table for bad sectors to the driver. If a driver supports the bad blocking standard, it is preferable to use that method to isolate bad blocks because the bad block forwarding makes the disk appear perfect, and such disks can then be copied with dd(1). The technique used by badsect is also less general than bad block forwarding, as badsect cannot make amends for bad blocks in the i-list of file systems or in swap areas. On some disks, adding a sector that is suddenly bad to the bad sector table currently requires the running of the standard formatter. Thus, to deal with a newly bad block or on disks where the drivers do not support the bad-blocking standard, badsect can be used to good effect. Use the badsect command on a quiet file system in the following way: Mount the file system and change to its root directory. Make a direc- tory BAD there. Run badsect, giving as argument the BAD directory followed by all the bad sectors you wish to add. (The sector numbers must be relative to the beginning of the file system, as reported in console error messages.) Change back to the root directory, unmount the file system, and run fsck(8) on the file system. The bad sectors should show up in two files or in the bad sector files and the free list. Have fsck remove files containing the offending bad sectors, but do not have it remove the BAD/nnnnn files. This operation will leave the bad sectors in only the BAD files. The badsect command works by giving the specified sector numbers in a mknod(2) system call, creating an illegal file whose first block address is the block containing bad sector and whose name is the bad sector number. When fsck discovers the file, it will ask "HOLD BAD BLOCK?" An affirmative response will cause fsck to convert the inode to a regular file containing the bad block. RESTRICTIONS
If more than one of the sectors comprised by a file system fragment are bad, you should specify only one to badsect, as the blocks in the bad sector files cover all the sectors in a file system fragment. ERRORS
The badsect command refuses to attach a block that resides in a critical area or is out of range of the file system. A warning is issued if the block is already in use. SEE ALSO
Commands: fsck(8) badsect(8)