The Raid controller is not showing no problems, as you put it.

RESYNCING means that the controller is remirroring the Raid1 disks because of a problem. Depending on the capacity of the Raid1 disks (they will typically be exactly the same size) this resyncing shouldn't take very long, however, whilst this is in progress, system response time will be impacted. Once complete, the status should become OPTIMAL.

If the resyncing is falling over for some reason then the process might be restarting over and over and OPTIMAL is never achieved. What for that. If that is the case I would be inclined to first if possible take the system down and re-seat all SCSI/SATA cables both ends (disk and mobo) and all disk power supply plugs. Reboot and see if the problem persists. If it does, then most likely one of the disks is faulty. It's possible but unlikely that the raid controller is faulty. All the moving parts are the disks.

You could remove the faulty raid1 drive (the one continuously resyncing) and put it on another machine running diagnostics. Perhaps completely reformat and try again. Otherwise, it's a new disk required.
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun Fire V440 and Patch 109147-39

Got an curious issue. I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on. The patch modified mainly the linker libraries and commands. ... (2 Replies)
Discussion started by: BOFH
2 Replies

2. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

3. Solaris

USB Hard Disk Drive Supported by Sun Fire V890

Hi, Can anyone suggest me any USB Hard Disk Drive which I can connect to Sun Fire V890 and take backup at a quick speed. A test with SolidState USB Hard Drive for backup work was taking writing at 2GB per hour for a 75GB backup. Regards, Tushar Kathe (1 Reply)
Discussion started by: tushar_kathe
1 Replies

4. Solaris

Sun Fire v440 hardware problem (can't get ok>)

First of all it's shut down 60 second after power on and write on console : SC Alert: Correct SCC not replaced - shutting managed system down! This is cured by moving out battery from ALOM card. Now server start to loop during the testing. That's on the console: >@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies

5. Solaris

error messages in Sun Fire V440

Hello, I am seeing error messages in V440 (OS = solaris 8). I have copied here : The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day.. I... (5 Replies)
Discussion started by: upengan78
5 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Firmware password Solaris Sun Fire v440

Hi: I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies

8. Solaris

Sun Fire v440 Over heat Problem.

Dear Team, I need some expert advice to my problem. We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies

10. Solaris

Removing a disk from SUN Fire V440 running Solaris 8

Hi, I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either. Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
vxdarestore(1M) 														   vxdarestore(1M)

NAME
vxdarestore - restore simple or nopriv disk access records SYNOPSIS
/etc/vx/bin/vxdarestore DESCRIPTION
The vxdarestore utility is used to restore persistent simple or nopriv disk access (da) records that have failed due to changing the naming scheme used by vxconfigd from c#t#d#-based to enclosure-based. The use of vxdarestore is required if you use the vxdiskadm command to change from the c#t#d#-based to the enclosure-based naming scheme. As a result, some existing persistent simple or nopriv disks go into the "error" state and the VxVM objects on those disks fail. vxdarestore may be used to restore the disk access records that have failed. The utility also recovers the VxVM objects on the failed disk access records. Note: vxdarestore may only be run when vxconfigd is using the enclosure-based naming scheme. Note: You can use the command vxdisk list da_name to discover whether a disk access record is persistent. The record is non-persistent if the flags field includes the flag autoconfig; otherwise it is persistent. The following sections describe how to use the vxdarestore utility under various conditions. Persistent Simple/Nopriv Disks in the rootdg Disk Group If all persistent simple or nopriv disks in the rootdg disk group go into the "error" state, use the following procedure: 1. Use the vxdiskadm command to change back to the c#t#d# based naming scheme. 2. Either shut down and reboot the host, or run the following command: vxconfigd -kr reset 3. If you want to use the enclosure-based naming scheme, add a non-persistent simple disk to the rootdg disk group, use vxdiskadm to change to the enclosure-based naming scheme, and then run vxdarestore. Note: If not all the disks in rootdg go into the error state, simply running vxdarestore restores those disks in the error state and the objects that that they contain. Persistent Simple/Nopriv Disks in Disk Groups other than rootdg If all disk access records in an imported disk group consist only of persistent simple and/or nopriv disks, the disk group is put in the "online dgdisabled" state after changing to the enclosure-based naming scheme. For such disk groups, perform the following steps: 1. Deport the disk group using the following command: vxdg deport diskgroup 2. Run the vxdarestore command. 3. Re-import the disk group using the following command: vxdg import diskgroup NOTES
Use of the vxdarestore command is not required in the following cases: o If there are no persistent simple or nopriv disk access records on an HP-UX host. o If all devices on which simple or nopriv disks are present are not automatically configurable by VxVM. For example, third-party drivers export devices that are not automatically configured by VxVM. VxVM objects on simple/nopriv disks created from such disks are not affected by switching to the enclosure based naming scheme. The vxdarestore command does not handle the following cases: o If the enclosure-based naming scheme is in use and the vxdmpadm command is used to change the name of an enclosure, the disk access names of all devices in that enclosure are also changed. As a result, any persistent simple/nopriv disks in the enclosure are put into the "error" state, and VxVM objects configured on those disks fail. o If the enclosure-based naming scheme is in use and the system is rebooted after making hardware configuration changes to the host. This may change the disk access names and cause some persistent simple/nopriv disks to be put into the "error" state. o If the enclosure-based naming scheme is in use, the device discovery layer claims some disks under the JBOD category, and the vxdd- ladm rmjbod command is used to remove remove support for the JBOD category for disks from a particular vendor. As a result of the consequent name change, disks with persistent disk access records are put into the "error" state, and VxVM objects configured on those disks fail. EXIT CODES
A zero exit status is returned if the operation is successful or if no actions were necessary. An exit status of 1 is returned if vxdare- store is run while vxconfigd is using the c#t#d# naming scheme. An exit status of 2 is returned if vxconfigd is not running. SEE ALSO
vxconfigd(1M), vxdg(1M), vxdisk(1M), vxdiskadm(1M), vxdmpadm(1M), vxintro(1M), vxreattach(1M), vxrecover(1M) VxVM 5.0.31.1 24 Mar 2008 vxdarestore(1M)
All times are GMT -4. The time now is 02:47 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.