Sponsored Content
Operating Systems Solaris Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1) Post 303044055 by hicksd8 on Thursday 13th of February 2020 05:15:54 AM
Old 02-13-2020
The Raid controller is not showing no problems, as you put it.

RESYNCING means that the controller is remirroring the Raid1 disks because of a problem. Depending on the capacity of the Raid1 disks (they will typically be exactly the same size) this resyncing shouldn't take very long, however, whilst this is in progress, system response time will be impacted. Once complete, the status should become OPTIMAL.

If the resyncing is falling over for some reason then the process might be restarting over and over and OPTIMAL is never achieved. What for that. If that is the case I would be inclined to first if possible take the system down and re-seat all SCSI/SATA cables both ends (disk and mobo) and all disk power supply plugs. Reboot and see if the problem persists. If it does, then most likely one of the disks is faulty. It's possible but unlikely that the raid controller is faulty. All the moving parts are the disks.

You could remove the faulty raid1 drive (the one continuously resyncing) and put it on another machine running diagnostics. Perhaps completely reformat and try again. Otherwise, it's a new disk required.
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun Fire V440 and Patch 109147-39

Got an curious issue. I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on. The patch modified mainly the linker libraries and commands. ... (2 Replies)
Discussion started by: BOFH
2 Replies

2. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

3. Solaris

USB Hard Disk Drive Supported by Sun Fire V890

Hi, Can anyone suggest me any USB Hard Disk Drive which I can connect to Sun Fire V890 and take backup at a quick speed. A test with SolidState USB Hard Drive for backup work was taking writing at 2GB per hour for a 75GB backup. Regards, Tushar Kathe (1 Reply)
Discussion started by: tushar_kathe
1 Replies

4. Solaris

Sun Fire v440 hardware problem (can't get ok>)

First of all it's shut down 60 second after power on and write on console : SC Alert: Correct SCC not replaced - shutting managed system down! This is cured by moving out battery from ALOM card. Now server start to loop during the testing. That's on the console: >@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies

5. Solaris

error messages in Sun Fire V440

Hello, I am seeing error messages in V440 (OS = solaris 8). I have copied here : The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day.. I... (5 Replies)
Discussion started by: upengan78
5 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Firmware password Solaris Sun Fire v440

Hi: I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies

8. Solaris

Sun Fire v440 Over heat Problem.

Dear Team, I need some expert advice to my problem. We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies

10. Solaris

Removing a disk from SUN Fire V440 running Solaris 8

Hi, I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either. Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
floppy(8)																 floppy(8)

NAME
floppy - format floppy disks SYNOPSIS
floppy --createrc >/etc/floppy floppy --format /dev/fd0 floppy --format A: floppygtk DESCRIPTION
The floppy utility does low-level formatting of floppy disks. floppy uses a simple interface for formatting disks in floppy controller drives and in ATAPI IDE floppy drives, such as LS-120 "Superdisk" drives. ATAPI IDE support requires a patch to the Linux kernel. Without a patched kernel floppy can only format disks in floppy controller drives. NOTE: Use caution in formatting anything other than standard 3.5" 1.4MB floppy disks in ATAPI IDE floppy drives. Most LS-120 drives, for example, accept a request to format 120MB high density disks, but most 120MB disks are not designed to be formatted. Low-level formatting will ruin them permanently. floppygtk is a GTK interface to the floppy utility. When started from an X terminal window, floppy will automatically run floppygtk. OPTIONS
--probe, -p - Probe for available floppy drives. floppy creates and displays a list of all detected floppy drives. --createrc, -r - Print a configuration file. floppy prints on standard output the results of the --probe option in a configuration file format. This configuration file should be saved as /etc/floppy. --showrc - List floppy drives configured in /etc/floppy. --capacity, -c - Show the available format capacities of the floppy drive. Most floppy drives can format disks of different capacities. --capacity lists each available format capacity as CxBxS where: C - number of cylinders, B - blocks per cylinder, S - block size, in bytes. --capacity also calculates how much that is, in kilobytes or megabytes. --format, -f - Format the disk in the floppy drive. --size=CxBxS, -s=CxBxS - Specify the size of the disk to format. --format uses the first format capacity reported by --capacity if the --size option is not specified. --ext2 - Create an ext2 (Linux) filesystem on the formatted floppy. This option requires the e2fsprogs package to be installed. This option simply runs mke2fs after formatting the floppy disk. --fat - Create a FAT (DOS) filesystem on the formatted floppy. This option requires the dosfstools package to be installed. This option simply runs mkdosfs after formatting the floppy disk. --noprompt, -n - Suppress verbose output produced by --capacity and --format. Use a raw output format that can be used by a front-end wrapper that runs floppy on the back-end. --eject - Eject the floppy from the drive (IDE floppy drives only). PROBING FOR AVAILABLE FLOPPY DRIVES
floppy --probe This command probes the hardware and reports on the available floppy drives. A typical output from --probe would be: floppy 0.12 Copyright 2001, Double Precision, Inc. floppy /dev/fd0: 3.5" HD idefloppy /dev/hda: LS-120 VER5 00 UHD Floppy Revision: F523M5A9 Serial number: 9803M9A03464 Here, floppy detected a high density floppy drive on /dev/fd0, and an IDE floppy drive on /dev/hda. CREATING A CONFIGURATION FILE
A configuration file, /etc/floppy must be created before floppy can format floppy disks. This configuration file can be created automati- cally by the --createrc option. Each line in the configuration file contains the following information: type<TAB>label<TAB>device. "<TAB>" is a single ASCII TAB character. "device" is the device entry for the floppy drive. floppy requires that all requests for formatting flop- pies must use only the devices that appear in this configuration file. "label" is an alias for this device. floppy accepts "label:" instead of the actual device entry, for example: "floppy --format A:". "type" is either "floppy" or "idefloppy". The --createrc option sets "A" as the label for the first floppy drive, and "B" for the second floppy drive. If --createrc finds more than two floppy drives, --createrc will use "FA", "FB", "FC", and so on. DETERMINING AVAILABLE FORMAT CAPACITIES
Most floppy drives can format disks of different capacities. The --capacity option shows possible format capacities on the specified floppy device. A typical IDE floppy drive may report the following capacities: $ floppy --capacity B: Formattable capacities for /dev/hda: 80x36x512 (1.40 Mb) 80x30x512 (1.17 Mb) 56x22x1024 (1.20 Mb) A standard floppy drive attached to the floppy controller may report the following capacities: $ floppy --capacity A: Formattable capacities for /dev/fd0: 80x36x512 (/dev/fd0H1440, 1.40 Mb) 80x18x512 (/dev/fd0D720, 720 Kb) 80x48x512 (/dev/fd0u1920, 1.87 Mb) 80x28x512 (/dev/fd0u1120, 1.09 Mb) 80x40x512 (/dev/fd0u1660, 1.56 Mb) 80x26x512 (/dev/fd0u1040, 1.01 Mb) 80x46x512 (/dev/fd0u1840, 1.79 Mb) 80x42x512 (/dev/fd0u1680, 1.64 Mb) The --capacity option reports each available format capacity as "cylinders x blocks-per-cylinder x block size". An IDE floppy drive actu- ally returns a total block count. --capacity simply tries some common blocks-per-cylinder values, until it finds one that fits. Format capacities of standard floppy drives are obtained from the floppy device driver. NOTE: IDE floppy drives may report format capacities only after a disk is inserted. Without a floppy disk, IDE floppy drives may not report any available format capacities, or they may report the primary format capacity that they are designed to format. For example, most LS-120 drives default to reporting 120mb when there is no disk inserted in the drive: $ floppy --capacity A: Formattable capacities for /dev/hda: 6848x36x512 (120.37 Mb) CAUTION: do not attempt to format 120Mb media in LS-120 drives. Most LS-120 disks are not user-formattable. They are factory-formatted, and attempts to format them in LS-120 drives will render them unusable (to be sure, check the label on the floppy itself). The floppy util- ity does not prevent one from trying to use any format capacity the IDE floppy drive claims to support. If the drive claims it can format a disk of the given capacity, floppy will oblige. FORMATTING
The --format option does a low-level format on the floppy. $ ./floppy --format --size=80x36x512 A: Formatting 1.40 Mb... 0% --size must specify a geometry returned by --capacity. If --size is absent, the first geometry is selected. For floppy controller drives, the status counter will go from 0% to 100%. With most IDE floppy drives the counter will remain at 0% until the format finishes. Some IDE floppy drives are capable of reporting format progress status, which will would allow --format to count up from 0% to 100%. $ ./floppy --format --verify A: The --verify option verifies the low-level format. For floppy controller drives, the floppy disk is read from start to finish, after the low-level format concludes. For IDE floppy drives, the format request to the drive will include a request to verify the low-level format. NOTE: Some IDE floppy drives ignore the verify request, or always verify low-level formats, whether or not it was requested. $ ./floppy --format -V A: The -V option is like --verify except that IDE floppy drive formats are verified manually - like floppy controller drive formats - by read- ing the floppy disk from start to finish. FILES
/etc/floppy - configuration file. /dev/fd[0-7] - floppy controller drives. /dev/hd[a-h] - ATAPI IDE floppy drives. SEE ALSO
fd(4), mkdosfs(8), mke2fs(8) Double Precision, Inc. February 24, 2003 floppy(8)