Operating Systems AIX Need to replace a broken PV in a VIO VG used for client LPARs (and it won't release the old one) Post 303044000 by maraixadm on Wednesday 12th of February 2020 10:09:09 AM
Old 02-12-2020
that worked, thank you (unmap, and remove partitions, via HMC virt storage mgmt)

Quote:
Originally Posted by zxmaus
is it still mapped to the VMs ? If so unmap it - then try to remove it again.
so an instance of seeing the forest and missing the tree you were looking for - I was trying to think along with AIX and figure out what entity was holding the LVs open. Ba-Doh, the VIO itself. Amazing how these episodes of having all the dots but not correcting the relevant ones happen. Thanks for the prod.
 

10 More Discussions You Might Find Interesting

1. AIX

Virtual Ethernet VIO HMC LPARs

Hi, I am little confused about the virtual Ethernet configuration on VIO and Client Partitions. There is alot of info on the internet but it gets more confusing.... If I have LHEA, it is very simple. Just assign LHEA (logical host ethernet adapter) to client partition -> run smitty tcpip and... (10 Replies)
Discussion started by: filosophizer
10 Replies

2. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

3. AIX

rebooting vio client

Hi, I would like to reboot vio client but I am not able to access vio client(I am not able to get putty) , I am able to get putty of vio server, is there any command by using which from vio server I can reboot vio client? (3 Replies)
Discussion started by: manoj.solaris
3 Replies

4. AIX

Finding cpu information on vio client

Hi, I am having single p series blade with Single Physcial CPU with dual core, on that vio server is installed, I have created vio client allocate 0.9 each cpu , now when I am running prtconf command on vio client it is showing "2" no of processor, My query using which command it will... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

5. AIX

Unable to connect VIO client

Hi I am facing very strange issue on my vio server 5 vio clients are confgured, now I am to connect 3 vio client , i am unable to connect 2 vio client my ip address,subnet mask,gateway is correct. i have rebooted and reconfigured the ip address, but issue is persists. Kindly suggest how to... (0 Replies)
Discussion started by: manoj.solaris
0 Replies

6. AIX

Inherited VIO server an LPARs

Lucky me, someone has installed a server and got it running with the best intentions, but leaving me a headache. :wall: We have a simple p520 with 4 disks. 2x145Gb & 2x300Gb. The smaller disk pair have been built into a VIO mirrored rootvg, and quite right too. The other two disks form a... (3 Replies)
Discussion started by: rbatte1
3 Replies

7. AIX

how will i know if a lun has been already mapped to a vio client

Hi im logged in to the vio servers now. when i give # lspv | wc -l i get the count as 6246 how will i know if a lun has been already mapped to a vio client or it is left free without mapping to any of the vio client ? (1 Reply)
Discussion started by: newtoaixos
1 Replies

8. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

9. AIX

cdrom confusion on the vio client lpar

Hi In my vio server I have the below output $ lsvopt | grep -i SAPSITGS sapsitgs_cdrom TL12UP.iso 3182 In my vio client lpar I have the below output root@sapsitgs:/ # lsdev -Cc cdromcd0 Available Virtual SCSI Optical Served by VIO Server cd1... (1 Reply)
Discussion started by: newtoaixos
1 Replies

10. AIX

Rebooting redundant VIOs and mirroring of PVs they serve to client LPARs

need to confirm: we have a system with two VIOs each serving a partition on a local disk to a client LPAR. That client LPAR has them both in a VG which is mirrored (exact). So each disk has a copy of the client LV that the client VG supports. This is the setup that was bequeathed to us by the... (3 Replies)
Discussion started by: maraixadm
3 Replies
GENLIB_COPY_UP_CON.3(October 1, 1997)									     GENLIB_COPY_UP_CON.3(October 1, 1997)

NAME
GENLIB_COPY_UP_CON - copy a physical connector from an instance in the current figure SYNOPSYS
#include <genlib.h> void GENLIB_COPY_UP_CON(index, conname, insname, newname) long index; char *insname; char *conname; char *newname; ORIGIN
This software belongs to the ALLIANCE CAD SYSTEM developed by the ASIM team at LIP6 laboratory of Universite Pierre et Marie CURIE, in Paris, France. Web : http://asim.lip6.fr/recherche/alliance/ E-mail : alliance-users@asim.lip6.fr PARAMETERS
index Connector index in the instance conname Name of the connector in the instance model insname Name of the instance the connector belongs to newname Name to be given to the connector in the current figure DESCRIPTION
COPY_UP_CON copies a instance connector into the current layout figure, and gives to the new connector the name newname. The instance con- nector is identified by its name, conname, and index, index. Two behaviour are expected, depending on the instance connector location regarding the abutment box of the current figure. Connector on the abutment box The figure connector is place right over the instance connector. The single connector is duplicated. Connector inside the abutment box The instance connector face is computed in the figure, and then, the connector is duplicated on the given face, at the right coordinates for this face. Then a wire is drawn between the instance connector and the figure connector in the connector layer. If newname is NULL, then not connector is copied up, on the segment is drawn to the side of the abutment box. ERRORS
"GENLIB_COPY_UP_CON impossible : missing GENLIB_DEF_PHFIG" No figure has been yet specified by a call to DEF_PHFIG. So it isn't possible to place a connector inside it. you must call DEF_PHFIG before any other layout action. "*** genlib error *** GENLIB_COPY_UP_CON impossible : connector conname index index of instance insname, current figure doesn't exist" The given connector does not exist in the current figure. EXAMPLE
#include <genlib.h> main() { /* Create a figure to work on */ GENLIB_DEF_PHFIG("cell"); . . GENLIB_PLACE_LEFT("gaer0_f", "insN", SYMXY); . . GENLIB_DEF_AB(0L, 0L, 0L, 0L); /* Put a connector */ GENLIB_COPY_UP_CON("i0", 1, "insN", "inz0"); /* Save that on disk */ GENLIB_SAVE_PHFIG(); } SEE ALSO
genlib(1), GENLIB_DEF_PHFIG(3), GENLIB_SAVE_PHFIG(3), GENLIB_COPY_UP_ALL_CON(3), GENLIB_COPY_UP_CON_FACE(3), GENLIB_PHCON(3), GEN- LIB_THRU_CON_H(3), GENLIB_THRU_CON_V(3). BUG REPORT
This tool is under development at the ASIM department of the LIP6 laboratory. We need your feedback to improve documentation and tools. PROCEDURAL GENERATION LANGUAGE
ASIM/LIP6 GENLIB_COPY_UP_CON.3(October 1, 1997)
All times are GMT -4. The time now is 12:33 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy