12-16-2019
It worked like a charm moving the mirrored pair of rootdisks & scc card to new identical hardware . Hostid & mac adresses remained the same in new hardware
10 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
I removed an external Sun disk (with data on it) from an old 2.6 system and added the disk to another 2.6 system. The new system seems to recognize the system (verified by the format command).
When try to mount I am getting, I got the error:
mount: /dev/dsk/c1t1d0s6 is not this fstype.
I... (3 Replies)
Discussion started by: sunshine
3 Replies
2. UNIX for Dummies Questions & Answers
Hi all,
I purchased a pci controller card and a 3rd hard drive to put Linux on my machine. The card did not enable me to boot to the 3rd drive so I could not get Mandrake to install. My motherboard is a Gigabyte GA-7DXR+. Can anyone point me to a reasonable card/connector which will allow me... (2 Replies)
Discussion started by: onestepto
2 Replies
3. Solaris
Hi,
I need to do an installation where I have identical hardware at both sites and create the installation at one site and take the disk to the other site. Question: Do I need to do anything special for the OS to come up properly?
thanks. (18 Replies)
Discussion started by: VirginiaSA
18 Replies
4. Solaris
Hi,
df -h display:
# df -h
Filesystem size used avail capacity Mounted on
/dev/dsk/c1t0d0s0 9.8G 8.1G 1.7G 84% /
/proc 0K 0K 0K 0% /proc
mnttab 0K 0K 0K 0% /etc/mnttab
fd 0K 0K 0K 0% /dev/fd
swap 1.0G 152K 1.0G 1% /var/run
swap 1.1G 24M 1.0G 3% /tmp
/dev/dsk/c1t0d0s3 57G 13G 43G 24%... (4 Replies)
Discussion started by: lamoul
4 Replies
5. Solaris
Hi,
The disks of my servers are getting full and I need to move the /export/home partition on to a new set of disks. I already have 2 mirrored disks and have added 2 more and mirrored them after creating the filesystem on them.
Do I just need to edit the /etc/vfstab and point the /export/home... (1 Reply)
Discussion started by: run_time_error
1 Replies
6. Solaris
We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue.
We have 2 LDOM configured on this server and this server running on single disk.
#... (8 Replies)
Discussion started by: rock123
8 Replies
7. Solaris
Hi All
Hope it's okay to post on this sub-forum, couldn't find a better place
I've got a 480R running solaris 8 with veritas volume manager managing all filesystems, including an encapsulated root disk (I believe the root disk is encapsulated as one of the root mirror disks has an entry under... (1 Reply)
Discussion started by: sunnyd76
1 Replies
8. UNIX for Dummies Questions & Answers
Hi,
I have server with 2 active disk, but disk 1 contain big part of os is falling,
how can i move everything to disk 2 and then remove the disk 1?
Thanks (4 Replies)
Discussion started by: prpkrk
4 Replies
9. Solaris
Hi Guys,
One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine
But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies
10. Linux
Hi
We have RHEL 7.3 running from local disk and we want to move it to storage.
I am unable to find any proper procedure to do this activity. Please help. (4 Replies)
Discussion started by: powerAIX
4 Replies
scc(7) Miscellaneous Information Manual scc(7)
NAME
scc - Serial keyboard/mouse/communications interface
SYNOPSIS
controller scc0 at tc0 slot 3 vector sccintr
DESCRIPTION
Two base board Zilog scc dual UARTS provide DEC 3000 series personal systems with keyboard, mouse, and serial communications interfaces.
The serial communications interfaces can operate at baud rates from B50 to B57600 (see tty(7)).
The driver for the scc interface supports hardware flow control using the Request to Send (RTS) and Clear to Send (CTS) signals. When
hardware flow control is enabled, the flow of input data is controlled by the RTS signal and the flow of output data is controlled by the
CTS signal. If the CTS signal is off, the driver will suspend output to that line until the CTS lead is reasserted. Likewise, the driver
will turn off the RTS lead to tell the device connected to the line to stop sending data as a result of congestion on the host side. When
the condition clears, the driver will turn on the RTS lead to tell the device to resume sending data.
In alternate console configurations (that is, no graphics head), communications port 2 (/dev/tty01) becomes the system console. The serial
system console port always operates at 9600 BPS, 8-bits, no parity. No modem or hardware flow control is supported.
RESTRICTIONS
Data communications equipment attached to the console serial port in alternate console configurations must be set to 9600 BPS, 8-bits, no
parity. The scc driver enforces this restriction.
Only communications port 1 (/dev/tty00) includes full modem control.
FILES
console terminal local terminal local terminal
RELATED INFORMATION
console(7), devio(7), modem(7), tty(7), MAKEDEV(8) delim off
scc(7)