Sponsored Content
Full Discussion: Show faulty shows PS1 faulty
Top Forums UNIX for Beginners Questions & Answers Show faulty shows PS1 faulty Post 303040474 by Peasant on Wednesday 30th of October 2019 03:57:35 AM
Old 10-30-2019
Perfectly normal.
When you unplug the PS, a fault is generated.

You can clear the fault, after you plugged it back in and it shows everything is ok.

Regards
Peasant.
This User Gave Thanks to Peasant For This Post:
 

10 More Discussions You Might Find Interesting

1. Solaris

Faulty PSU - but its still working !?!

Hello We have a power supply in an x4100 (x86) and it seems to be faulty but it is still working!?! (this box only has one PSU). We are getting Orange flashing warning light on the front of the box and the LED labelled “rear PSu” is solid orange ...We don't seem to have had any syslog error... (8 Replies)
Discussion started by: hcclnoodles
8 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Replacing a faulty volume

Hi All, I replace a sub-mirror of a mirrored volume by using below command: #metadetach d10(mirror) d11(striped) #metattach d10 d13(other striped) With above process I successfully replaced a faulty volume. I want to knoow if the process I followed is right. Or if not, what... (5 Replies)
Discussion started by: naw_deepak
5 Replies

4. Solaris

fmadm faulty output

Hi everyone, I wanted to ask a question about fmadm and explorer outputs. Recently found out that an error shows up in fmadm saying "mb is faulty but still in service" so we took an explorer send to Oracle Support. Error led wasn't on but we didn't want to risk the probability. They came up... (1 Reply)
Discussion started by: royalliege
1 Replies

5. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

6. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

7. HP-UX

FAULTY DISK replacement HP rx4640

Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies

8. Solaris

Is it possible to set a PSU as faulty on Solaris

Hi, I'm trying to generate an alert related to Power Supply Failure. As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty" Any ideas are welcome and highly appreciated -Thanks (3 Replies)
Discussion started by: justsam
3 Replies

9. Red Hat

HBA card faulty

Hi, How to determine if HBA card in getting faulty from linux host ? any pointers. (2 Replies)
Discussion started by: saurabh84g
2 Replies

10. Hardware

Faulty parts in a frame

Hello, Following parts need to be replaced in a frame as suggested by IBM 1. Flexible Cable 2. Service Processor Card Would these faulty parts impact all lpars which are there in this frame? Best regards, Vishal (5 Replies)
Discussion started by: admin_db
5 Replies
hpialarms(1)							      OpenHPI							      hpialarms(1)

NAME
hpialarms - A openhpi sample application that shows "Alarm Control" management instruments SYNOPSIS
hpialarms [-a -b -c -i -m -n -p -o -x] DESCRIPTION
hpialarms walks the RPT (Resource Present Table) for resouces that have "Alarm Control" management instruments (SAHPI_CTRL_LED). OPTIONS
-c1 sets Critical Alarm on -c0 sets Critical Alarm off -m1 sets Major Alarm on -m0 sets Major Alarm off -n1 sets Minor Alarm on -n0 sets Minor Alarm off -p1 sets Power Alarm on -p0 sets Power Alarm off -i5 sets Chassis ID on for 5 sec -i0 sets Chassis ID off -a1 sets Disk A fault on -a0 sets Disk A fault off -b1 sets Disk B fault on -b0 sets Disk B fault off -d[byte] sets raw Alarm byte -o sets all Alarms off -x show eXtra debug messages SAMPLE OUTPUT
hpialarmpanel ver 0.6 RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0 rptentry[0] resourceid=1 tag: Mullins RDR[45]: ctltype=2:1 oem=0 Chassis Identify Control RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED state = off RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED state = ON RDR[46]: ctltype=0:0 oem=0 Cold Reset Control RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED state = off RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED state = off SEE ALSO
AUTHORS
Authors of this man page: Peter D Phan (pdphan@users.sourceforge.net) 2.14.1 2009-11-23 hpialarms(1)
All times are GMT -4. The time now is 08:25 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy