I see that you are trying to connect to the system through the ILOM.console connection, this is normally for mainenance/initial configuration only and all other instances you would connect to the server/host using an other method.
In most instances this would be ssh or similar protocol, assuming that you have setup the networking on the server. Connecting to the host through the console would be ok to bring the server up (although not usual) in a production environment. However it would not be the way to use the server when it's in everyday use.
Additionally forcing the ILOM to connect as the console could lead to a situation where you may not be able to use it as intended. As you are aware there are both serial and network ILOM's on these boxes and having had a look around on the Oracle site (because I've never seen anyone request to have the /HOST/console as a default condition) I can't find much on this subject.
To ensure that the host comes to the login prompt you would need to set the policy for a power cycle to the server as;
You may also want to set the Automatic System Recovery using;
An at the ok prompt set;
This should mean that if the power is removed the system will return to it's previous state.
Regards
Gull04
These 2 Users Gave Thanks to gull04 For This Post:
We are running SCO Unix under Unixware 2.1.3 (really old!). I would appreciate if someone could show me the code of a script to automatically "ftp" one or more files to another SCO Unix computer on the nightly basis, then gracefully termninate the ftp session. Thanks for your help. (3 Replies)
Hi Friends,
Can any of you explain me about the below line of code?
mn_code=`env|grep "..mn"|awk -F"=" '{print $2}'`
Im not able to understand, what exactly it is doing :confused:
Any help would be useful for me.
Lokesha (4 Replies)
heya,
can someone help me with following problem.
i am not sure how far you know the catalina.sh script from tomcat. when i start my tomcat with "catalina.sh run" then the startup-process-output will be printed out on the console, but the tomcat process is started in current shell/session, so... (1 Reply)
Hi,
I have line in input file as below:
3G_CENTRAL;INDONESIA_(M)_TELKOMSEL;SPECIAL_WORLD_GRP_7_FA_2_TELKOMSEL
My expected output for line in the file must be :
"1-Radon1-cMOC_deg"|"LDIndex"|"3G_CENTRAL|INDONESIA_(M)_TELKOMSEL"|LAST|"SPECIAL_WORLD_GRP_7_FA_2_TELKOMSEL"
Can someone... (7 Replies)
How to use "mailx" command to do e-mail reading the input file containing email address, where column 1 has name and column 2 containing “To” e-mail address
and column 3 contains “cc” e-mail address to include with same email.
Sample input file, email.txt
Below is an sample code where... (2 Replies)
Hi All,
I have 2 pipe delimited files viz., file_old and file_new. I'm trying to compare these 2 files, and extract all the different rows between them into a new_file.
comm -3 < sort file_old < sort file_new > new_file
I am getting the below error:
-ksh: sort: cannot open
But if I do... (7 Replies)
Dear community, as already done tons of times, I prepare the RedHat installation on VMWare, then clone it with clonezilla, and finally restore it on final server. Due to different hrdware, I have to boot from rhel-server-7.4-x86_64-boot.iso cd and rewrite the initramfs that contains the hardware... (3 Replies)
Hello, fellow Unixers and Macers,
I'll run several OS X versions each on its own dedicated partition. Partitions won't be seeing each other (by editing fstab). Question: will I be able to copy files between those partitions? Partition #1: Mavericks. Partition #2: HighSierra (2 Replies)
Hello.
System : opensuse leap 42.3
I have a bash script that build a text file.
I would like the last command doing :
print_cmd -o page-left=43 -o page-right=22 -o page-top=28 -o page-bottom=43 -o font=LatinModernMono12:regular:9 some_file.txt
where :
print_cmd ::= some printing... (1 Reply)
Discussion started by: jcdole
1 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.8.7pre1 May 2010 IRSEND(1)