GPIV_RECIMG(1) General Commands Manual GPIV_RECIMG(1) NAME
gpiv_recimg - captures images from a IIDC-compliant camera with IEE1394 connection. SYNOPSIS
gpiv_recimg [-f filename] [-h | --help] [-v | --version] [-V | --verbose] [-x | --x_corr] < stdin > stdout DESCRIPTION
gpiv_recimg records image pairs for Particle Image velocimetry (PIV). The code supports IIDC-compliant cameras that are connected to the computer with IEEE1394. Such an image pair may be analysed by gpiv_rr in the cross-correlation mode for PIV. This program uses the IMG parameters. The command line options are explained below. Options -f filename Overrides stdin and stdout with filename. The filename has to be given without its .r extension. Output will be written to filename.r. -h | --help On-line help. -v | --version Print version information on standard output, then exit successfully. -V | --verbose program behaves more verbose during operation showing what is going on -x | --x_corr Records two succesive image frames for cross-correlation and stores as a single image. In this case, gpiv_combing is not needed. SEE ALSO
gpivtools AUTHOR
Gerber Van der Graaf BUGS
The program is still in a very prelimary state. 19 Januari 2005 GPIV_RECIMG(1)