10-10-2019
we are doing it on the root level without issues on vios 3.1.21 which essentially is AIX 7.2.3.3 including managing passwords. IBM does not care.
These 2 Users Gave Thanks to zxmaus For This Post:
7 More Discussions You Might Find Interesting
1. AIX
Hi,
I want to know wheather partition size for installation of vio client can be specified on vio server
example
If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies
2. AIX
Hi,
I would like to reboot vio client but I am not able to access vio client(I am not able to get putty) , I am able to get putty of vio server,
is there any command by using which from vio server I can reboot vio client? (3 Replies)
Discussion started by: manoj.solaris
3 Replies
3. AIX
Hi,
I am having single p series blade with Single Physcial CPU with dual core,
on that vio server is installed, I have created vio client allocate 0.9 each cpu , now when I am running prtconf command on vio client it is showing "2" no of processor,
My query using which command it will... (1 Reply)
Discussion started by: manoj.solaris
1 Replies
4. AIX
Hi
I am facing very strange issue on my vio server 5 vio clients are confgured, now I am to connect 3 vio client , i am unable to connect 2 vio client my ip address,subnet mask,gateway is correct.
i have rebooted and reconfigured the ip address, but issue is persists.
Kindly suggest how to... (0 Replies)
Discussion started by: manoj.solaris
0 Replies
5. AIX
Hi
im logged in to the vio servers now.
when i give
# lspv | wc -l
i get the count as 6246
how will i know if a lun has been already mapped to a vio client or it is left free without mapping to any of the vio client ? (1 Reply)
Discussion started by: newtoaixos
1 Replies
6. AIX
Hi
In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID.
Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies
7. AIX
Hi
In my vio server I have the below output
$ lsvopt | grep -i SAPSITGS
sapsitgs_cdrom TL12UP.iso 3182
In my vio client lpar I have the below output
root@sapsitgs:/ # lsdev -Cc cdromcd0 Available Virtual SCSI Optical Served by VIO Server
cd1... (1 Reply)
Discussion started by: newtoaixos
1 Replies
LEARN ABOUT DEBIAN
update-guestfs-appliance
LIBGUESTFS(8) System Manager's Manual LIBGUESTFS(8)
NAME
update-guestfs-appliance - update the supermin appliance used by libguestfs
SYNOPSIS
update-guestfs-appliance
DESCRIPTION
update-guestfs-appliance creates or updates the supermin appliance for use with libguestfs. It uses febootstrap for this, therefore access
to the package repository is needed.
A supermin appliance contains only lists of files and directories. The contents of the referenced files are only copied into an ad-hoc
filesystem whenever libguestfs starts a virtual machine. Therefore, calling update-guestfs-appliance is only needed after libguestfs has
been installed or when the filesystem layouts or dependencies of needed packages on the host system have been changed.
FILES
/usr/lib/guestfs/make.sh (the script that does the actual work),
/usr/lib/guestfs/supermin.d/hostfiles
/usr/lib/guestfs/supermin.d/base.img
SEE ALSO
guestfish(1), guestmount(1), febootstrap(8), febootstrap-supermin-helper(8).
AUTHOR
update-guestfs-appliance and this manual page were written by Hilko Bengen <bengen@debian.org>, for the Debian project (and may be used by
others).
August 2011 LIBGUESTFS(8)