Sponsored Content
Operating Systems Solaris IPMP group failed on Solaris 9 Post 303038593 by solaris_1977 on Friday 6th of September 2019 05:11:25 PM
Old 09-06-2019
I am sorry to have confused you. I clubbed two issues in one. I will re-word this issue.

IPMP is already configured on this server. Suddenly I got alert that IPMP group is failed over due to some error. When I logged into the server, I found that ce2 was in FAILED status, instead of the usual INACTIVE state.

/etc/hostname.ce2 file is there and the physical interface is also present. There was never any change in its setup. Physically I can see light blinking on network port behind the server. But since this interface is in FAILED states, IPMP is broken. Running snoop on ce2, is not giving me any result. To test this, I tried to detach bge0 and it is not working
Code:
# if_mpadm -d bge0
Offline failed as there is no other functional interface available in the multipathing group for failing over the network access.
#
# cat /etc/hostname.ce2
sbprda-app1-ce2 group sbsd_data netmask + broadcast + deprecated -failover standby up
#

---------------------UPDATE-----------------
Found that cable had problem. After replacing that, I was able to fix this issue

Last edited by solaris_1977; 09-06-2019 at 11:44 PM..
This User Gave Thanks to solaris_1977 For This Post:
 

9 More Discussions You Might Find Interesting

1. Solaris

Solaris IP Multipathing (IPMP) Help

Hello All, I work for a Health care company at a local trauma hospital. I maintain a Picture Archiving and Communication System (PAC's). Basically, any medical images (X-Ray, CT, MRI, Mammo, etc) are stored digitally on the servers for viewing and dictation from diagnostic stations. I took over... (10 Replies)
Discussion started by: mainegeek
10 Replies

2. Solaris

Does Veritas Cluster work with IPMP on Solaris 10?

Does Veritas Cluster work with IPMP on Solaris 10? If anyone has set it up do you have a doc or tips? I have heard several different statements ranging from , not working at all to Yes it works! Great How? * Test and Base IPs???? * configure the MultiNICB agent ? I can give details... (1 Reply)
Discussion started by: dfezz1
1 Replies

3. Solaris

IPMP group failure when gateway not detected

A problem happened with me, I was configuring IP for two network interfaces, and when I rebooted the system, everything is working but after like 3 or 5 minutes it will tell me that the whole IPMP group has failed ! I tried to troubleshoot, so I found that the gateway is not reachable..so I... (4 Replies)
Discussion started by: Sun Fire
4 Replies

4. Solaris

how to configure IPMP in solaris 9

Hi friends , can anyone provide me the complete steps to configure IPMP in solaris 9 or 10 provided i have two NIC card ? regards jagan (4 Replies)
Discussion started by: jaganblore
4 Replies

5. Solaris

Solaris IPMP

Can any one please explain me the concept behind IPMP in solaris clustering.Basic explanation would be really appreciated... Thanks in Advance vks (2 Replies)
Discussion started by: vks47
2 Replies

6. Solaris

Solaris 10 branded zone with IPMP

All. I am trying to create a 10 branded zone on a Sol 11.1 T5. The Global is using IPMP...so aggregating is out of the question. Has anyone successfully created a branded zone with IPMP? If they have can you please show me the steps you took to get this to run. Thanks (4 Replies)
Discussion started by: aeroforce
4 Replies

7. Solaris

IPMP over aggregate in Solaris 11

hi all, i start with solaris 11 and i am disapointed by the change on ip managing. i want to set a ipmp over tow aggregate but i dont find any doc and i am lost with the new commande switch1 net0 aggregate1 | net1 aggregate1 |-----| |... (1 Reply)
Discussion started by: sylvain
1 Replies

8. Solaris

New to Solaris IPMP (conversion from Linux)

Hi all, I been reading examples of how to setup IPMP and how it differs from Etherchannel. However, i am still unsure of how it really works and i hope gurus here can shed some light on the questions I have below while i will lab it up for my own test -> q1) for IPMP, there is no such thing... (23 Replies)
Discussion started by: javanoob
23 Replies

9. Solaris

Solaris 10 IPMP - failback=no

Hi all, Just a few questions -> Is an "OFFLINE" interface going back to "ONLINE" consider as a failback by IPMP ? I have "FAILBACK=no" in my /etc/default/mpathd; however when i do the following (igb0 and igb7 are in the same ipmp link based group) q1) why does "if_mpadm -r igb7" cause... (0 Replies)
Discussion started by: javanoob
0 Replies
if_mpadm(1M)                                              System Administration Commands                                              if_mpadm(1M)

NAME
if_mpadm - change operational status of interfaces within a multipathing group SYNOPSIS
/usr/sbin/if_mpadm -d interface_name /usr/sbin/if_mpadm -r interface_name DESCRIPTION
Use the if_mpadm utility to change the operational status of interfaces that are part of an IP multipathing group. If the interface is operational, you can use if_mpadm -d to detach or off-line the interface. If the interface is off-lined, use if_mpadm -r to revert it to its original state. When a network interface is off-lined, all network access fails over to a different interface in the IP multipathing group. Any addresses that do not failover are brought down. Network access includes unicast, broadcast, and multicast for IPv4 and unicast and multicast for IPv6. Addresses marked with IFF_NOFAILOVER do not failover. They are marked down. After an interface is off-lined, the system will not use the interface for any outbound or inbound traffic, and the interface can be safely removed from the system without any loss of network access. The if_mpadm utility can be applied only to interfaces that are part of an IP multipathing group. OPTIONS
The if_mpadm utility supports the following options: -d interface_name Detach or off-line the interface specified by interface_name. -r interface_name Reattach or undo the previous detach or off-line operation on the interface specified by interface_name. Unless the -d option was used to detach or off-line the interface, this option will fail. EXAMPLES
Example 1: Detaching an Interface Use the following command to off-line or detach the interface. All network access will failover from hme0 to other interfaces in the same IP multipathing group. If no other interfaces are in the same group, the operation will fail. example% if_mpadm -d hme0 Example 2: Reattaching an Off-line Interface Use the following command to undo the previous operation. Network access will failback to hme0. example% if_mpdadm -r hme0 ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ |Interface Stability |Unstable | +-----------------------------+-----------------------------+ SEE ALSO
ifconfig(1M), in.mpathd(1M), attributes(5) DIAGNOSTICS
off-line failed as there is no other functional interface available in the multipathing group for failing over the network access. This message means that other interfaces in the group are failed over already or the multipathing configuration was not suitable for com- pleting a failover. off-line cannot be undone because multipathing configuration is not consistent across all the interfaces in the group. This message means that some interfaces in the IP multipathing group are not configured consistently with other interfaces in the group, for example, one of the interfaces in the group does not have an IFF_NOFAILOVER address. SunOS 5.10 3 Sep 2002 if_mpadm(1M)