Sponsored Content
Operating Systems SCO SCO 5.0.7 driver for HP SmartArray P410i Controller on Proliant DL380 G7? Post 303037217 by Stuart1946 on Friday 26th of July 2019 05:43:24 AM
Old 07-26-2019
SCO 5.0.7 driver for HP SmartArray P410i Controller on Proliant DL380 G7?

Hi


I hope this is the right forum.


I am attempting to install SCO 5.0.7 on a Proliant DL380 G7 with a Smart Array P410I Controller.
I need a driver for this. Can anybody point me to a download?
Thanks in anticipation.
 

10 More Discussions You Might Find Interesting

1. SCO

ultra 320 scsi raid controller driver for sco 5.0.6

I am facing a problem to install sco 5.0.6 in Dell Power Edge SC1420 which raid controller is ultra 320 scsi raid controller . how/from where to download the ultra 320 scsi raid controller driver for sco 5.0.6. Plz help with any idea karzon (1 Reply)
Discussion started by: karzon
1 Replies

2. SCO

driver needed for hp smartarry p200i sas raid controller

recently we have purchased hp proliant ml350 g5 server and configured raid 5 with hp smartarray p200i sas controller.but i could not found any sas raid controller hp smartarry p200i driver for sco unix 5.0.7 :(.i searched on hp support site,but no use.any one can help. (3 Replies)
Discussion started by: prakrithi
3 Replies

3. UNIX for Dummies Questions & Answers

SCO Openserver 6.0 Insall on HP DL380 serverl

Trying to install Openserver 6.0 on this server which has an integrated Smart Array P400. Install halts with the message ....... "Incorrect Disk Partitioning .........................." I havent yet got to the "divvy" and disk partitioning section of the install section so I am... (2 Replies)
Discussion started by: farmacy
2 Replies

4. SCO

SCO 5.0.7 no root disk controller found error during install

I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd. I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies

5. SCO

Loading SCO 507 on HP ProLiant ML350 G6

This is my first load of SCO OpenServer v5.0.7 on a HP ProLiant ML350 G6. When it asks me to identify the source media it can't find it no matter how I respond. The SCO compatible page says it used the on board SATA DVD-ROM on Port 2 of the embedded SATA controller with "Legacy IDE emulation (as... (8 Replies)
Discussion started by: farmboy
8 Replies

6. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

7. Debian

HP ProLiant DL380 G4 w/ Debian... If your familiar with this machine please help.

Hello, I have a few questions about this server. It has two CPU's 3.20 ghz / 800 mhz / 1MB L2 5120 MB RAM 6 hard disks on HP Smart Array 6i controller (36.4 GB Ultra320 SCSI HD each) RAID set to RAID 5 (5 discs) with one spare (6th disk) USB, 2 Ethernet ports, 1 ILO port, 1 SCSI port ... (2 Replies)
Discussion started by: Marcus Aurelius
2 Replies

8. SCO

Getting error sco unix 507 from cdrom:no controller for device you chosen

Installing SCO UNIX 507 on Dell Poweredge T610. It has no floppy so I downloaded the BTLD onto CD from SCO site to load without floppy drive. BTLD loads ok. when i get to the Media to be used, no matter what option i chose i get the error: No controller for device you have chosen. During bootup you... (9 Replies)
Discussion started by: romanglad112
9 Replies

9. SCO

How to change raid controller driver ? (hardware change)

Hello I'm trying to virtualize an instance of Sco Unix 5.0.5 in VirtualBox (called VM-A) , but sco I have problems set to launch with the new raid controller . The physical machine has a raid controller adaptec (alad driver) but VirtualBox uses buslogic (blc driver) What ... (3 Replies)
Discussion started by: flako
3 Replies

10. SCO

SCO OS 6 Driver for LSIL SAS1064E Raid Controller

Hi all, A client has an SCO OpenServer Server 6.0, that is running on an HP ProLiant Box and they lost the root password. Its equipped with a Doal-Core Intel Pentium Processor. They don't have any media or emergency disk anymore. I tried to boot with the CD Rom, then "Tools", then exit to... (7 Replies)
Discussion started by: thm2222
7 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Since Linux 4.14, the following Smart Array boards are also supported: Smart Array 5300 Smart Array 5312 Smart Array 532 Smart Array 5i Smart Array 6400 Smart Array 6400 EM Smart Array 641 Smart Array 642 Smart Array 6i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Smart Array P400 Smart Array P400i Smart Array P600 Smart Array P700m Smart Array P800 Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the latest version of this page, can be found at https://www.kernel.org/doc/man-pages/. Linux 2017-09-15 HPSA(4)
All times are GMT -4. The time now is 09:12 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy