- I can see the new drive, with the correct serial #
Code:
lscfg -v -l pdisk18
pdisk18 U5886.001.P15R082-P1-D3 Physical SAS Disk Drive
Manufacturer................IBM
Machine Type and Model......ST3300656SS
FRU Number..................10N7208
ROS Level and ID............45363043
Serial Number...............3QP2CYYW
However, when trying to Create an Array Candidate pdisk and Format to 528 Byte Sectors it doesn't show up.
==
Create an Array Candidate pdisk and Format to 528 Byte Sectors
│ pdisk22 00000600 Active Array Candidate 283.8GB │
│ pdisk23 00000700 Active Array Candidate 283.8GB │
│ pdisk24 00000800 Active Array Candidate 283.8GB │
│ pdisk25 00000900 Active Array Candidate 283.8GB
===
Neither in the array conf:
sissas3 FFFFFFFF Primary PCI-X266 Ext Tri-x4 3Gb SAS RAID Adapter
sissas2 00000000 AWC linked Redundant cache protection for sissas3
hdisk9 00FF0000 Degraded RAID 10 Array 851.4GB
pdisk21 00000500 Active Array Member 283.8GB
pdisk27 00000B00 Active Array Member 283.8GB
pdisk17 00000100 Active Array Member 283.8GB
pdisk20 00000400 Active Array Member 283.8GB
pdisk16 00000000 Active Array Member 283.8GB
pdisk19 00000300 Active Array Member 283.8GB
pdisk24 00000800 Active Array Candidate 283.8GB
pdisk22 00000600 Active Array Candidate 283.8GB
pdisk23 00000700 Active Array Candidate 283.8GB
pdisk25 00000900 Active Array Candidate 283.8GB
pdisk26 00000A00 Active Hot Spare 283.8GB
pdisk18 00000200 Missing Disk 283.8GB
Dear Friends,
I need to configure T5240 with Internal SAS RAID HBA(SG-XPCIESAS-R-INT-Z).. T5240 uses 8 hard disks... From the documents of RAID card I have found that I need to create a jump start server to include three packages SUNWaac, StorMan, SUNWgccruntime if Im using solaris10 5/08...
... (5 Replies)
We have a dual-controller StorEdge 3320 disk array with 5 disks (each 320 MB). Four disks have been set up in a RAID-5 configuration with the remaining disk acting as a hot spare. There is a single logical drive which has been partitioned into 3 slices.
The disk array is to be simultaneously... (14 Replies)
May I know how can I add a new SSA pdisk into array and become usable hdisk? I have inserted a 36GB SSA disk into enclosure and done the "cfgmgr" and I can see it already been regconized as pdisk47.
I would like to make it a system disk in order for me to add to my volume group. Please let me... (3 Replies)
Hi,
I`m on SunFire480R with Solaris 10. Disk in rootdg group failed, so it was replaced. However, I cannot make Veritas initalise the replaced disk:
# vxdctl enable
# vxdisk list c1t0d0s2
Device: c1t0d0s2
devicetag: c1t0d0
type: auto
flags: online error private autoconfig... (1 Reply)
Hi,
Is there an easy way to find the disk-type from the command line or with another api ? sdparm works for SAS but not for SATA, hdparm works for SATA but not SAS.
Thanks (1 Reply)
Hi,
a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced.
here is how I did that.
1) created identical partition table on the new disk.
2) attached the mirrors using md commands.
The whole procedure is given... (5 Replies)
Hi,
a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced.
here is how I did that.
1) created identical partition table on the new disk.
2) attached the mirrors using md commands.
The whole procedure is given below:... (2 Replies)
I need to add a VMware virtual disk to the 99-oracle-asmdevices.rules file but the OS is not assigning a WWID to the disk. It has been fdisk'd and a single partition created.
What TAG inside the file needs to be added? the Program scsi-id does not work for some reason. latest patches... (0 Replies)
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Hello,
I would like to check how many SAS disks and its size per disk for the whole power system. As per my understanding, if we assign the SAS controller to LPAR, then we can see the disk in lpar smitty command.
How can we check from the Power machine(physical ones) as well? I think the... (5 Replies)
Discussion started by: Phat
5 Replies
LEARN ABOUT DEBIAN
log::dispatch::array
Log::Dispatch::Array(3pm) User Contributed Perl Documentation Log::Dispatch::Array(3pm)NAME
Log::Dispatch::Array - log events to an array (reference)
VERSION
version 1.001
SYNOPSIS
use Log::Dispatch;
use Log::Dispatch::Array;
my $log = Log::Dispatch->new;
my $target = [];
$log->add(Log::Dispatch::Array->new(
name => 'text_table',
min_level => 'debug',
array => $target,
));
$log->warn($_) for @events;
# now $target refers to an array of events
DESCRIPTION
This provides a Log::Dispatch log output system that appends logged events to an array reference. This is probably only useful for testing
the logging of your code.
METHODS
"new"
my $table_log = Log::Dispatch::Array->new(\%arg);
This method constructs a new Log::Dispatch::Array output object. Valid arguments are:
array - a reference to an array to append to; defaults to an attr on
$table_log
array
This method returns a reference to the array to which logging is being performed.
log_message
This is the method which performs the actual logging, as detailed by Log::Dispatch::Output.
AUTHOR
Ricardo Signes, "<rjbs@cpan.org>"
BUGS
Please report any bugs or feature requests through the web interface at <http://rt.cpan.org>. I will be notified, and then you'll
automatically be notified of progress on your bug as I make changes.
COPYRIGHT
Copyright 2008 Ricardo SIGNES, all rights reserved.
This program is free software; you can redistribute it and/or modify it under the same terms as Perl itself.
perl v5.10.1 2008-04-29 Log::Dispatch::Array(3pm)