Dear Friends,
I need to configure T5240 with Internal SAS RAID HBA(SG-XPCIESAS-R-INT-Z).. T5240 uses 8 hard disks... From the documents of RAID card I have found that I need to create a jump start server to include three packages SUNWaac, StorMan, SUNWgccruntime if Im using solaris10 5/08...
... (5 Replies)
We have a dual-controller StorEdge 3320 disk array with 5 disks (each 320 MB). Four disks have been set up in a RAID-5 configuration with the remaining disk acting as a hot spare. There is a single logical drive which has been partitioned into 3 slices.
The disk array is to be simultaneously... (14 Replies)
May I know how can I add a new SSA pdisk into array and become usable hdisk? I have inserted a 36GB SSA disk into enclosure and done the "cfgmgr" and I can see it already been regconized as pdisk47.
I would like to make it a system disk in order for me to add to my volume group. Please let me... (3 Replies)
Hi,
I`m on SunFire480R with Solaris 10. Disk in rootdg group failed, so it was replaced. However, I cannot make Veritas initalise the replaced disk:
# vxdctl enable
# vxdisk list c1t0d0s2
Device: c1t0d0s2
devicetag: c1t0d0
type: auto
flags: online error private autoconfig... (1 Reply)
Hi,
Is there an easy way to find the disk-type from the command line or with another api ? sdparm works for SAS but not for SATA, hdparm works for SATA but not SAS.
Thanks (1 Reply)
Hi,
a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced.
here is how I did that.
1) created identical partition table on the new disk.
2) attached the mirrors using md commands.
The whole procedure is given... (5 Replies)
Hi,
a little while ago, one of the GPT Partitioned hard disk had gone faulty in a Mirror RAID and is now successfully replaced.
here is how I did that.
1) created identical partition table on the new disk.
2) attached the mirrors using md commands.
The whole procedure is given below:... (2 Replies)
I need to add a VMware virtual disk to the 99-oracle-asmdevices.rules file but the OS is not assigning a WWID to the disk. It has been fdisk'd and a single partition created.
What TAG inside the file needs to be added? the Program scsi-id does not work for some reason. latest patches... (0 Replies)
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Hello,
I would like to check how many SAS disks and its size per disk for the whole power system. As per my understanding, if we assign the SAS controller to LPAR, then we can see the disk in lpar smitty command.
How can we check from the Power machine(physical ones) as well? I think the... (5 Replies)
Discussion started by: Phat
5 Replies
LEARN ABOUT DEBIAN
tie::array::sorted
Tie::Array::Sorted(3pm) User Contributed Perl Documentation Tie::Array::Sorted(3pm)NAME
Tie::Array::Sorted - An array which is kept sorted
SYNOPSIS
use Tie::Array::Sorted;
tie @a, "Tie::Array::Sorted", sub { $_[0] <=> $_[1] };
push @a, 10, 4, 7, 3, 4;
print "@a"; # "3 4 4 7 10"
DESCRIPTION
This presents an ordinary array, but is kept sorted. All pushes and unshifts cause the elements in question to be inserted in the appropri-
ate location to maintain order.
Direct stores ("$a[10] = "wibble"") effectively splice out the original value and insert the new element. It's not clear why you'd want to
use direct stores like that, but this module does the right thing if you do.
If you don't like the ordinary lexical comparator, you can provide your own; it should compare the two elements it is given. For instance,
a numeric comparator would look like this:
tie @a, "Tie::Array::Sorted", sub { $_[0] <=> $_[1] }
Whereas to compare a list of files by their sizes, you'd so something like:
tie @a, "Tie::Array::Sorted", sub { -s $_[0] <=> -s $_[1] }
LAZY SORTING
If you do more stores than fetches, you may find Tie::Array::Sorted::Lazy more efficient.
AUTHOR
Original author: Simon Cozens
Current maintainer: Tony Bowden
BUGS and QUERIES
Please direct all correspondence regarding this module to: bug-Tie-Array-Sorted@rt.cpan.org
This module was originall written as part of the Plucene project. However, as Plucene no longer uses this, it is effectively unmaintained.
COPYRIGHT AND LICENSE
Copyright (C) 2003-2006 Simon Cozens and Tony Bowden.
This program is free software; you can redistribute it and/or modify it under
the terms of the GNU General Public License; either version 2 of the License,
or (at your option) any later version.
This program is distributed in the hope that it will be useful, but WITHOUT
ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS
FOR A PARTICULAR PURPOSE.
perl v5.8.8 2004-10-10 Tie::Array::Sorted(3pm)