Hi,
I have Solaris-10 server and link aggregation is configured on this in below way
There will be switch replacement, so one by one, link will go down from one side. Before that activity, is there any way to check/test, if server will work fine, if one side goes down ? In same way, as used to check by if_mpadm -d in ipmp.
Hi there
I have a requirement to provide failover to our customer boxes in case of interface / switch failure, I have been looking at Solaris Link Aggregation with LACP and I wanted to ask a question
Ive seen multiple websites that say the following
Does this also mean that if the... (2 Replies)
Hi there
I have a requirement to provide failover to our customer boxes in case of interface / switch failure, I have been looking at Solaris Link Aggregation with LACP and I wanted to ask a question
Ive seen multiple websites that say the following
Does this also mean that if the... (1 Reply)
I have some linux machines that I am trying to increase the throughput to on a single connection. They connect to a switch with two 1GbE lines and the switch does not have Link Aggregation support for these machines. I have tried bonding with balance-rr, balance-alb, but the machines can only... (4 Replies)
Hi,
I need to setup a hacmp cluster (my first one, we usually use VCS on AIX), but I require more network bandwith than a normal gigabit etherchannel setup can provide, so I am thinking about using linkaggregation - 2 active adapters to one switch and a single backup adapter to another switch... (4 Replies)
Hi,
Hoping someone can offer some advice on something i have not dealt with before.
We have a server that seems to have some very strange configuration done on it. It has 2 physical NIC's and rather than both be aggregated into LAN900 we have 1 in LAN900 and 1 in LAN901? (See Below)... (2 Replies)
Me again :)
I'm trying to find a page describing the L2, L3 und L4 modes of dladm.
It's nice to read "hashed by ip header", but how should I use that?
On the file-server it's ok to have the six interfaces serving six clients each on it's own. But an rsync connection via switch between two... (8 Replies)
Hi,
I want to Break the Link Aggregation. My aggregation are lan0+lan1 = lan900.
Now I want to break this and put the IP in lan0. But i have cluster environment and this is the main database server.
So It need to change in cluster script.
But I dont know where I have to change it.
Please... (1 Reply)
Hi,
I'm not from the Solaris world and some of these things are new to me. Can someone tell me if it is possible to configure link aggregation without using LACP?
I am told etherchannel was setup without LACP. (3 Replies)
I have setup link aggregation with 3 interfaces on my solaris 10 system.
All looks good but my problem is that the traffic is only going out bge0 and not the other 2 links.
bash-4.3# dladm show-aggr -s
key:33 ipackets rbytes opackets obytes %ipkts %opkts
... (3 Replies)
Hi
ihave three link of internet and iwant to put one linux front of a firewall that this three linux speard firewall such az load balance and fialover but dont close any port and protocol and only firewall have been internet what way can i use for it ?
are there any script and services do that... (0 Replies)
Discussion started by: mnnn
0 Replies
LEARN ABOUT DEBIAN
vconfig
VCONFIG(8) System Manager's Manual VCONFIG(8)NAME
vconfig - VLAN (802.1q) configuration program.
SYNOPSIS
vconfig [lots of long options]
DESCRIPTION
The vconfig program allows you to create and remove vlan-devices on a vlan enabled kernel. Vlan-devices are virtual ethernet devices which
represents the virtual lans on the physical lan.
OPTIONS
add [interface-name] [vlan-id]
Creates a vlan-device on [interface-name]. The resulting vlan-device will be called according to the nameing convention set.
rem [vlan-device]
Removes the named vlan-device.
set_flag [vlan-device] 0 | 1
When 1 (the default since 2.6.18), ethernet header reorders are turned on. Dumping the device will appear as a common ethernet
device without vlans. When 0 however, ethernet headers are not reordered, which results in vlan tagged packets when dumping the
device. Usually the default gives no problems, but some packet filtering programs might have problems with it.
set_egress_map [vlan-device] [skb-priority] [vlan-qos]
This flags that outbound packets with a particular skb-priority should be tagged with the particular vlan priority vlan-qos. The
default vlan priority is 0.
set_ingress_map [vlan-device] [skb-priority] [vlan-qos]
This flags that inbound packets with the particular vlan priority vlan-qos should be queued with a particular skb-priority. The
default skb-priority is 0.
set_name_type VLAN_PLUS_VID | VLAN_PLUS_VID_NO_PAD | DEV_PLUS_VID | DEV_PLUS_VID_NO_PAD
Sets the way vlan-device names are created. Use vconfig without arguments to see the different formats.
NOTES VLAN will use Broadcom's NICE interface when the network device supports it. This is necessary, since usually the hardware of these
devices already removes the vlan tag from the ethernet packet. The set_flag option on vlan-devices created on such a physical net-
work device will be ignored. Dumping the network-device will show only untagged(non-vlan) traffic, and dumping the vlan-devices
will only show traffic intended for that vlan, without the tags.
FILES
/proc/net/vlan/config
/proc/net/vlan/[vlan-device]
SEE ALSO ip(8), ifconfig(8)AUTHORS
This manual page was written by Ard van Breemen <ard@kwaak.net>
The vlan patch is written by Ben Greear <greearb@candelatech.com>
VCONFIG(8)