Sponsored Content
Operating Systems OS X (Apple) 12-Core MacPro (2013) kernel_task over 1200% Post 303033977 by Neo on Monday 15th of April 2019 01:14:30 PM
Old 04-15-2019
Thanks Dennis,

Yeah, I saw that "disable SIP" ... mv the .plist file method but did not try it for a number of reasons; but its moving on towards 1AM here so I am going off grid for a while.

I revisit when I awake up and plug it back onto the power socket on my UPS.
 

6 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Can I use a general printer(HP LaserJet 1200) on solaris?

can it be used? how to config it? thanks (4 Replies)
Discussion started by: cloudsmell
4 Replies

2. OS X (Apple)

kernel_task help

I installed 10.5 (Leopard) on my G4 733 Mhz (after minor tampering with the install package, just switched a boolean FALSE to TRUE). Everything works fine after startup, but once I sleep the computer and wake it back up, kernel_task starts using at as much CPU runtime as it can, as in past 90%.... (0 Replies)
Discussion started by: peter.story
0 Replies

3. Solaris

T5140 CPU Speed is 1200 Mhz or 1165 Mhz?

Hi bros, CPU speed of Sun Sparc Enterprise T5140 in data sheet is 1200 Mhz. Why it shows in "prtdiag -v" command each thread just has speed at 1165 Mhz. Thank you, tien86 (4 Replies)
Discussion started by: tien86
4 Replies

4. Hardware

2013 Apple Mac Pro 2.7GHz 12 Core/64GB/256GB Flash/Dual AMD FirePro D700 6GB 6,1

Hey MacPro users. I just bought a refurbished 13-Core MacPro with 64GB of RAM for a cybersecurity gaming project I'm working on. Could not wait for the new MacPro in 2019, so this will have to do: 2013 Apple Mac Pro 2.7GHz 12 Core/64GB/256GB Flash/Dual AMD FirePro D700 6GB 6,1 Now, I'm... (0 Replies)
Discussion started by: Neo
0 Replies

5. OS X (Apple)

DiskSpeedTest 256GB OEM v. 960GB Transcend 855 SSD MacPro 2013, 12-Core, 64GB RAM

Before Upgrade: https://www.unix.com/members/1-albums177-picture1220.png After Upgrade: https://www.unix.com/members/1-albums177-picture1221.png (0 Replies)
Discussion started by: Neo
0 Replies

6. OS X (Apple)

Warning! Upgrade to Catalina 10.15.3 Crashes MacPro (2013) - Will Not Boot !

WARNING! Just upgraded my MacPro (2013) from Catalina 10.15.2 to 10.15.3. After the routine download and restart for upgrade installation, the Mac would not boot. Totally crashed. Now, I'm in the process of a 15 hour restore from my last time machine backup. I'm not very happy with... (3 Replies)
Discussion started by: Neo
3 Replies
ONEAC(8)							    NUT Manual								  ONEAC(8)

NAME
oneac - Driver for Oneac UPS equipment NOTE
This man page only documents the hardware-specific features of the oneac driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
This driver supports various Oneac UPS families: o EG (late 80s, early 90s, plug-in serial interface card) o ON (early and mid-90s, plug-in serial interface card) o OZ (mid-90s on, DB-25 std., interface slot) o OB (early 2000's on, big cabinet, DB-25 std., interface slot) If your UPS is equipped with the Basic Interface card, use the genericups(8) driver. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5) file: testtime=num Change battery test time from the 2 minute default. offdelay=num Change shutdown delay time from 0 second default. INSTANT COMMANDS
This driver supports the following Instant Commands. (See upscmd(8)) All UPS units shutdown.return Turn off the load possibly after a delay and return when power is back. shutdown.stop Stop a shutdown in progress. shutdown.reboot Shut down the load briefly while rebooting the UPS. test.failure.start Starts a 15 second long simulation of an input power failure. test.battery.start.quick Start a "quick" battery test. The default time is 2 minutes. This time can be set in the ups.conf file. See testime above. test.battery.stop Stops a battery test that is in progress. All ON UPS units reset.input.minmax Reset the minimum and maximum input line voltage values seen since the last reset or power on. Newer ON UPS units test.panel.start Start testing the UPS panel. test.battery.start.deep Start a "deep" battery test. This test runs the UPS until the low battery point and then returns to the AC line. reset.input.minmax Reset the minimum and maximum input line voltage values seen since the last reset or power on. beeper.enable Enable UPS beeper/buzzer. beeper.disable Disable UPS beeper/buzzer. beeper.mute Mutes the UPS beeper/buzzer for the current alarm condition(s). WRITABLE VARIABLES
See upsrw(8) to see what variables are writable for the UPS. Note If your UPS supports writing battery.runtime.low, the new set value is to be entered in minutes (up to 99) but the reported value is reported in seconds (set value * 60). Note If your UPS supports input.transfer.low and input.transfer.high, those values are used to create an allowable output range. The UPS will do what it can to keep the output voltage value within the defined range (for example: tap change or switch to inverter). AUTHOR
Bill Elliot <bill@wreassoc.com>, Eric Lawson <elawson@inficad.com> SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 ONEAC(8)
All times are GMT -4. The time now is 11:23 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy