Hi - as you can see in your results the xdisk tool with 1 MB block size drove the V7000 up to 3.4 Gigabytes per second.
The reason I mentioned using 0x40000 for the hdisk max_transfer is because that is what the SDDPCM driver used by default and I have seen better V7000 performance with this value compared to the 0x80000 default that AIX MPIO uses.
You can leave the FC adapter at 0x100000 or you could change it to 0x200000. This tunable is independent of the hdisk one.
If you do reduce the hdisk max_transfer from 0x80000 to 0x40000 you can then compare the xdisk results now that you have already run it once.
Thanks
Dean
--- Post updated at 09:05 PM ---
Regarding your question of tuning max_xfer_size you can do it dynamically assuming your LUN's have multiple paths. (lspath to confirm)
can someone tell me a good site to go to in order to learn this. please do not recommen nay books because i dont have interest in that. if you know of any good sites with good straight forward explanation on how to split loads on machines that has excessive loading, please let me know
Also,... (1 Reply)
Hi all,
long time ago I posted something, but now, it is needed again :(
Currently, I am handling with a big NFS Server for more than 200 clients, this sever has to work with 256 NFSDs. Because of this huge amount of NFSDs, there are thousands of small write accesses down to the disk and... (3 Replies)
Hi to all,
I'm interested in finding an introduction about Performance Tuning under Unix (or Linux); can somebody please point me in the right direction?
Best regards (1 Reply)
Sorry,
This is out of scope of this group.But I require the clarification pretty urgently.
My Oracle database is parallely enabled.
Still,in a particular table queries do not work "parallely" always.
How is this? (9 Replies)
Hi All,
In last one week, i have posted many questions in this portal. At last i am succeeded to make my 1st unix script.
following are 2 points where my script is taking tooooo long.
1. Print the total number of records excluding header & footer. I have found that awk 'END{print NR -... (2 Replies)
Hi all,
From Googling, I found that the basics used for troubleshooting UNIX/AIX performance issues are commands like vmstat, iostat and sar. I believe these are generic commands regardless of what UNIX flavour is in used, only difference being is the format of the output.
In a real case... (2 Replies)
Please take a look at this system and give your analysis / advice. Can it be tuned to get a better performance?
We are not getting more hardware ressources at the moment.
We have to live with what we have. Application running on the system is SAS. OS is AIX 6.1
Let me know if you need output of... (7 Replies)
Dear all,
I have a Local zone , where users feel that performance is not good.
Is it wise to collect the inputs from the local zone rather than taking from the global zone.
And also Can I tune from Global zone , so that it will reflect in local zone.
Rgds
rj (2 Replies)
Overview:
Introduction
What Does Success Mean?
What Does Performance Mean?
Every Picture is Worth a Thousand Words
Work Like a Physicist
Work Like You Walk - One Step at a Time
Learn to Know Your System
Choose Your Weapons!
Tools of the Trade 1 - vmstat
A Little Theory Along the Way -... (1 Reply)
Discussion started by: bakunin
1 Replies
LEARN ABOUT SUSE
elvtune
ELVTUNE(8) System Manager's Manual ELVTUNE(8)NAME
elvtune - I/O elevator tuner
SYNOPSIS
elvtune [-r r_lat] [-w w_lat] [-b b_max] device...
elvtune -h
elvtune -v
DESCRIPTION
elvtune allows to tune the I/O elevator per blockdevice queue basis. The tuning can be safely done at runtime. Tuning the elevator means
being able to change disk performance and interactiveness. In the output of elvtune the address of the queue tuned will be shown and it can
be considered as a queue ID. For example multiple partitions in the same harddisk will share the same queue and so tuning one partition
will be like tuning the whole HD.
OPTIONS -r r_lat
set the max latency that the I/O scheduler will provide on each read.
-w w_lat
set the max latency that the I/O scheduler will provide on each write.
-b b_max
max coalescing factor allowed on writes when there are reads pending in the queue.
-h help.
-v version.
NOTE
Actually the only fields tunable are those relative to the IO scheduler. It's not possible to select a one-way or two-way elevator yet.
For logical blockdevices like LVM the tuning has to be done on the physical devices. Tuning the queue of the LVM logical device is useless.
RETURN VALUE
0 on success and 1 on failure.
HISTORY
Ioctls for tuning elevator behaviour were added in Linux 2.3.99-pre1.
AUTHORS
Andrea Arcangeli <andrea@suse.de> SuSE
AVAILABILITY
The elvtune command is part of the util-linux-ng package and is available from ftp://ftp.kernel.org/pub/linux/utils/util-linux-ng/.
Version 1.0 14 March 2000 ELVTUNE(8)