Hi Bakunin,

You are right. I'm not so understand well the FC work, zoning work, and IBM virtualization work.
Just want to know the FC port work and multipath(redundant) work.

We talk about another aspect. For example, if you have 2 FC cards, each has 2 ports. So 4 ports are connected to the LUN. Assuming that, 3 ports failed and we have only 1 port. So we still can see the LUN? and in case 2 ports failed, we can see the LUN? In regard redundant, with 4 line connected to LUN, the system is only down if 4 lines were down/broken, even if 1 line is still available, the system still running. Please correct me this.

I'm surprised is that in my environment I can see the LUN on 2 still-working FC cards, but not boot device. After 1 more FC is up again, I can see. So confused about this.
 

9 More Discussions You Might Find Interesting

1. AIX

Fibre channel drivers on RS/6000 aix 5L

Want to configure IBM raid strorage but the aix 5L cds do not have the drivers for the fibre channels. The machine is RS/6000. I have gone to IBM downlaodable sites but i can't find the drivers? help pliz:mad: (4 Replies)
Discussion started by: Zim-Aix-Guru
4 Replies

2. AIX

Install Fibre Card AIX 5.3

Hello, I have two systems that are being prepared to be SAN attached .. can anyone tell me any specific checks I should perform prior to the cards being installed... I am aware of firmware / OS level and relevant drivers, is there anything else? thanks Chris. (8 Replies)
Discussion started by: chlawren
8 Replies

3. AIX

Power6 Virtual Fibre Channel Adapter

Hello, Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter. It is similar to virtual scsi adapter. In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Discussion started by: filosophizer
1 Replies

4. Solaris

USCSICMD ioctl calls for Fibre Channel(FC) devices on Solaris 10?

Hi , I have wrtitten a C program that issues USCSICMD ioctl call to the tape devices attached on solaris sparc 10. I was able to get the required information from all SCSI tape devices attached using the utility. But, whenever it is run on FC attached tape drives , the program returns an error... (0 Replies)
Discussion started by: naveen448
0 Replies

5. AIX

Setting up a secure channel with AIX

hi i have two aix servers and I was asked to setup a secure shell between the two servers using the sybase user. Can any one let me know how to do this (2 Replies)
Discussion started by: newtoaixos
2 Replies

6. Hardware

Fibre Channel HBA recommendations?

We will be buying new Xeon E5-based servers for our datacenter and were wondering which Fibre Channel host bus adapters we should select for these. The choices are Emulex or QLogic (8Gb FC HBAs). Anybody have any recommendations on which is the better choice? Thanks in advance. (1 Reply)
Discussion started by: atahmass
1 Replies

7. AIX

AIX - Fibre Adapter and IBM Storage

Hello, Just a quick question Usually from a PSERIES if you want to connect to IBM SAN Storage you connect the IBM SAN Storage through a SAN Switch something like this --- however my question Can you connect from Pseries directly to San Storage without SAN Switch what would be... (8 Replies)
Discussion started by: filosophizer
8 Replies

8. Solaris

Fibre channel link down on booting Solaris server

Hi I had power issue that affected a server, in which I had power ON the server SPARC T1-B3 running solaris 10. After power on the system stops at ok prompt, them I issued the following commands: {0} ok setenv auto-boot? false auto-boot? = false {0} ok reset-all SPARC T3-1B,... (10 Replies)
Discussion started by: fretagi
10 Replies

9. Solaris

Fibre Channel link not ready on Netra 240

Hi, One of my Netra 240 went into hung state and I had to reboot it. I powered it off and tried booting it again but unsuccessful. It is not connected to SAN and have local disks. Not able to boot in failsafe mode too. There are two disks of 72GB, both are mirrored in SVM. It complains about... (5 Replies)
Discussion started by: solaris_1977
5 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)
All times are GMT -4. The time now is 06:28 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy