Sponsored Content
Full Discussion: AIX: DLPAR VFC - HMC v9
Operating Systems AIX AIX: DLPAR VFC - HMC v9 Post 303030877 by bakunin on Monday 18th of February 2019 11:11:33 AM
Old 02-18-2019
Moderator's Comments:
Mod Comment moved to AIX forum
 

10 More Discussions You Might Find Interesting

1. AIX

AIX HMC LSCOD with space

I am trying to run the lscod command against an HMC that has managed system names with spaces. Tried enclosing the managed system names in quotes; single and double. How do I get the command to run? ssh hmcname lscod -m 'managed system 1' -t cap -r proc -c cuod Thanks, ~Donavon (0 Replies)
Discussion started by: djlerman
0 Replies

2. AIX

AIX and HMC installation issue

I started the AIX install with a fiber channel disk, and let it run: restricted by GSA ADP Schedule Contract with IBM Corp. . . . . . << End of copyright notice for perfagent.tools >>. . . . ... (2 Replies)
Discussion started by: Gideon1a
2 Replies

3. AIX

Virtualizing the Fiber card (VFC) on P595

Hi, We have a P595 machine with a dual port Fiber card per VIOs. We have two VIOs in the box. VIO1: ---> 2 port Fiber Card VIO2: ---> 2 port Fiber Card One port on each fiber card is utilized. Connected to SAN switches. We are getting all disks from SAN both for VIOs and LPARs. Now... (0 Replies)
Discussion started by: aixromeo
0 Replies

4. AIX

AIX HMC - Getting Colon ":" in output

Hi, I am executing below commands on HMC. I see that there is only colon ":" in output. Can someone please help why I am getting ":" in output? Why I am not getting proper output? xxxxx@yyyyhmc1:~> viosvrcmd -m PCC-p590#2-SN024D8F0 -p ppvio1 -c "lsmap -all" :xxxxx@yyyyhmc1:~> viosvrcmd... (0 Replies)
Discussion started by: marya
0 Replies

5. AIX

Upgrade AIX without HMC

Hi all, i would like to know if it's possible upgrade AIX 5.3 to 6.1 on a LPAR without use the HMC. so i would like to know if i must use the console to do it or i can do all from the up&running system on LPAR. Thanks in advance. Mario (4 Replies)
Discussion started by: Zio Bill
4 Replies

6. AIX

HMC - tracking dlpar

I am trying to generate a report to track dlpar operation performed on a MS and was wondering if anyone has done this before. I can get history from HMC using lssvcevents , but this does not give me details as to what quantity was added or removed . Any thoughts ? Thanks (3 Replies)
Discussion started by: mk8570
3 Replies

7. AIX

Install AIX lpar via hmc, can't access cd drive

Hi , I would like to access the cd drive of , i have power series server , and have lpars . I try to install AIX in an lpar via HMC, but it can't access the cd drive. how i can make installtion or make the the cd drive accessible in hmc or in power series server? Thanks in advance (2 Replies)
Discussion started by: prpkrk
2 Replies

8. AIX

Install AIX , do i need hmc console

Hi, For installing aix on power series , do i need to install hmc first? or i can connect hmc after? Rgs, (7 Replies)
Discussion started by: prpkrk
7 Replies

9. AIX

View IP of HMC from AIX

Trying to get the IP address of the HMC connected to some servers running AIX 6 and 7. I thought this would be as easy as running 'lsrsrc IBM.MCP IPAddresses', but when I run that command, the resource is empty. Is there some where else I should be looking, or is there a reason why this resource... (5 Replies)
Discussion started by: acascianelli
5 Replies

10. AIX

IBM VIOS AIX HMC Error

hello P6 was managed by HMC, tried to install on it VIOS 2.2.6 and got this error message Hosting requires a hosting partition -- boot not permitted vios-4 - imgbb.com then after creating an lpar in HMC got this message B2001230 vios-3 - imgbb.com anyone know how to solve this... (3 Replies)
Discussion started by: filosophizer
3 Replies
strace(1M)																strace(1M)

NAME
strace - write STREAMS event trace messages to standard output SYNOPSIS
mod sub pri DESCRIPTION
gets STREAMS event trace messages from STREAMS drivers and modules via the STREAMS log driver and writes these messages to standard output. By default, without arguments writes all STREAMS trace messages from all drivers and modules. with command-line arguments limits the trace messages received. The arguments, which must be specified in groups of three, are: mod Specifies the STREAMS module identification number from the streamtab entry. sub Specifies a subidentification number (often corresponding to a minor device). pri Specifies a tracing priority level. gets messages of a level equal to or less than the value specified by pri. Only posi- tive integer values are allowed. The value can be used for any argument in the command line to indicate that there are no restrictions for that argument. Multiple sets of the three arguments can be specified to obtain the messages from more than one driver or module. Only one process can open the STREAMS log driver at a time. When is invoked, the log driver compares the sets of command line arguments with actual trace messages, returning only messages that sat- isfy the specified criteria. STREAMS event trace messages have the following format: seq time tick pri ind mod sub text Components are interpreted as follows: seq Trace event sequence number. time Time the message was sent expressed in hh:mm:ss. tick Time the message was sent expressed in machine ticks since the last boot. pri Tracing priority level as defined by the STREAMS driver or module that originates the messages. ind Can be any combination of the following three message indicators: The message has also been saved in the error log. The message signaled a fatal error. The message has also been mailed to the system administrator. mod Module identification number of the trace message source. sub Subidentification number of the trace message source. text Trace message text. runs until terminated by the user. EXAMPLES
Display all trace messages received from the driver or module identified by mod Display trace messages of any tracing priority level from the driver or module identified by mod and its minor devices identified by the sub or Display the trace messages from the same driver or module and subs but limit the priority levels to 0 for subs 2 and 3; 1 for sub 4, driver or module WARNINGS
Running with several sets of arguments can impair STREAMS performance, particularly for those modules and drivers that are sending the mes- sages. Also be aware that may not be able to handle a large number of messages. If drivers and modules return messages to too quickly, some may be lost. FILES
NLS catalog for SEE ALSO
strclean(1M), strerr(1M), strlog(7). strace(1M)
All times are GMT -4. The time now is 01:34 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy